期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
On Advanced Control Methods toward Power Capture and Load Mitigation in Wind Turbines 被引量:2
1
作者 Yuan Yuan Jiong Tang 《Engineering》 SCIE EI 2017年第4期494-503,共10页
This article provides a survey of recently emerged methods for wind turbine control. Multivariate control approaches to the optimization of power capture and the reduction of loads in components under time-varying tur... This article provides a survey of recently emerged methods for wind turbine control. Multivariate control approaches to the optimization of power capture and the reduction of loads in components under time-varying turbulent wind fields have been under extensive investigation in recent years. We divide the related research activities into three categories: modeling and dynamics of wind turbines, active control of wind turbines, and passive control of wind turbines. Regarding turbine dynamics, we discuss the physical fundamentals and present the aeroelastic analysis tools. Regarding active control, we review pitch control, torque control, and yaw control strategies encompassing mathematical formulations as well as their applications toward different objectives. Our survey mostly focuses on blade pitch control, which is considered one of the key elements in facilitating load reduction while maintaining power capture performance. Regarding passive control, we review techniques such as tuned mass dampers, smart rotors, and microtabs. Possible future directions are suggested. 展开更多
关键词 wind turbine control approach Power optimization Load mitigation
下载PDF
Wind Generator Stabilization with Doubly-Fed Asynchronous Machine
2
作者 武黎 王志新 《Journal of Shanghai Jiaotong university(Science)》 EI 2007年第2期271-282,共12页
This paper investigates the function of doubly-fed asynchronous machine(DASM)with emphasis placed on its ability to the stabilization of the power system including wind generators.P(active power)and Q(reactive power)c... This paper investigates the function of doubly-fed asynchronous machine(DASM)with emphasis placed on its ability to the stabilization of the power system including wind generators.P(active power)and Q(reactive power)compensation from DASM can be regulated independently through secondary-excitation controlling.Simulation results by power system computer aided design(PSCAD)show that DASM can restore the wind-generator system to a normal operating condition rapidly even following severe transmission-line failures.Comparison studies have also been performed between wind turbine pitch control and proposed method. 展开更多
关键词 doubly-ted asynchronous mahine(DASM) wind generator wind turbine pitch control power system computer aided design(PSCAD)
下载PDF
Optimal Auxiliary Frequency Control of Wind Turbine Generators and Coordination with Synchronous Generators 被引量:23
3
作者 Ming Sun Yong Min +3 位作者 Lei Chen Kaiyuan Hou Deming Xia Hangyin Mao 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第1期78-85,共8页
Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of con... Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of control schemes,including frequency droop control and emulated inertia control,which simulate the response characteristics of the synchronousgenerator (SG). This paper plans to further explore the optimalauxiliary frequency control of the wind turbine based on previousresearch. First, it is determined that the virtual inertia control haslittle effect on the maximum rate of change of frequency (MaxROCOF)if the time delay of the control link of WTG is taken intoconsideration. Secondly, if a WTG operates in maximum powerpoint tracking (MPPT) mode and uses the rotor deceleration forfrequency modulation, its optimal auxiliary frequency control willcontain only droop control. Furthermore, if the droop control isproperly delayed, better system frequency response (SFR) willbe obtained. The reason is that coordination between the WTGand SG is important for SFR when the frequency modulationcapability of the WTG is limited. The frequency modulationcapability of the WTG is required to be released more properly.Therefore, when designing optimal auxiliary frequency controlfor the WTG, a better control scheme is worth further study. 展开更多
关键词 Frequency droop control power system frequency security rate of change of frequency(ROCOF) virtual inertia control wind turbine generator auxiliary frequency control
原文传递
Feedforward Control for Wind Turbine Load Reduction with Pseudo-LIDAR Measurement 被引量:2
4
作者 Jie Bao Hong Yue +1 位作者 William E.Leithead Ji-Qiang Wang 《International Journal of Automation and computing》 EI CSCD 2018年第2期142-155,共14页
A gain-scheduled feedforward controller, based on pseudo-LIDAR (light detection and ranging) wind speed measurement, is designed to augment the baseline feedback controller for wind turbine's load reduction in abov... A gain-scheduled feedforward controller, based on pseudo-LIDAR (light detection and ranging) wind speed measurement, is designed to augment the baseline feedback controller for wind turbine's load reduction in above rated operation. The pseudo-LIDAR measurement data are generated from a commercial software- Bladed using a designed sampling strategy. The nonlinear wind turbine model has been simplified and linearised at a set of equilibrium operating points. The feedforward controller is firstly developed based on a linearised model at an above rated wind speed, and then expanded to the full above rated operational envelope by employing gain scheduling strategy. The combined feedforward and baseline feedback control is simulated on a 5MW industrial wind turbine model. Simulation studies demonstrate that the proposed control strategy can improve the rotor and tower load reduction performance for large wind turbines. 展开更多
关键词 wind turbine control light detection and ranging (LIDAR) measurement feedforward control load reduction gainscheduling disturbance rejection.
原文传递
Analysis of grid-connected voltage stability of FSCWT based on bifurcation theory
5
作者 HE Ai-huan ZHANG Rui-ping DONG Hai-ying 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2018年第1期16-24,共9页
This paper studies on the change mechanisms of the voltage stability caused by the grid connection of front-end speed-controlled wind turbines(FSCWT)integrating into power system.First of all,the differential algebrai... This paper studies on the change mechanisms of the voltage stability caused by the grid connection of front-end speed-controlled wind turbines(FSCWT)integrating into power system.First of all,the differential algebraic equations describing the dynamic characteristics of wind turbines are illustrated.Then,under the guidance of IEEE3 node system model,the influence of the angular velocity of wind turbines,the reactive power and the active power at load bus on the voltage stability of grid-connection has been analyzed by using bifurcation theory.Finally,the method of linear-state feedback control has been applied to the original system in accordance with the bifurcation phenomenon of grid-connected voltage caused by the increase in the active power at load bus.Research shows that voltage at the grid-connected point would be changed with the fluctuation of turbines angular velocity.And increasing its reactive power can enhance voltage at the grid-connected point;problem of bifurcation at the grid-connected point can be delayed when increasing the gain k s of feedback controller within a certain range. 展开更多
关键词 bifurcation theory power system front-end speed controlled wind turbines(FSCWT) voltage stability
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部