期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Validation of Full-Converter Wind Power Plant Generic Model Based on Actual Fault Ride-Through Measurements
1
作者 O. Tsernobrovkin A. Perdana +1 位作者 I. Palu J. Kilter 《Journal of Energy and Power Engineering》 2010年第4期54-62,共9页
Modeling and validation of full power converter wind turbine models with field measurement data are rarely reported in papers. In this paper an aggregated generic dynamic model of the wind farm consisting of full powe... Modeling and validation of full power converter wind turbine models with field measurement data are rarely reported in papers. In this paper an aggregated generic dynamic model of the wind farm consisting of full power converter wind turbines is composed and the model validation based on actual field measurements is performed. The paper is based on the measurements obtained from the real short circuit test applied to connection point of observed wind farm. The presented approach for validating the composed model and fault ride-through (FRT) capability for the whole wind park is unique in overall practice and its significance and importance is described and analyzed. 展开更多
关键词 Real short-circuit test full converter wind turbine modeling model validation generic model fault ride-through (FRT) wind power development security of supply power system stability.
下载PDF
Transient Stability Analysis of Grid-connected Converters in Wind Turbine Systems Based on Linear Lyapunov Function and Reverse-time Trajectory
2
作者 Mohammad Kazem Bakhshizadeh Sujay Ghosh +1 位作者 Guangya Yang Łukasz Kocewiak 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第3期782-790,共9页
As the proportion of converter-interfaced renewable energy resources in the power system is increasing,the strength of the power grid at the connection point of wind turbine generators(WTGs)is gradually weakening.Exis... As the proportion of converter-interfaced renewable energy resources in the power system is increasing,the strength of the power grid at the connection point of wind turbine generators(WTGs)is gradually weakening.Existing research has shown that when connected with the weak grid,the stability of the traditional grid-following controlled converters will deteriorate,and they are prone to unstable phenomena such as oscillation.Due to the limitations of linear analysis that cannot sufficiently capture the stability phenomena,transient stability must be investigated.So far,standalone time-domain simulations or analytical Lyapunov stability criteria have been used to investigate transient stability.However,the time-domain simulations have proven to be computationally too heavy,while analytical methods are difficult to formulate for larger systems,require many modelling assumptions,and are often conservative in estimating the stability boundary.This paper proposes and demonstrates an innovative approach to estimating the transient stability boundary via combining the linear Lyapunov function and the reverse-time trajectory technique.The proposed methodology eliminates the need of time-consuming simulations and the conservative nature of Lyapunov functions.This study brings out the clear distinction between the stability boundaries with different post-fault active current ramp rate controls.At the same time,it provides a new perspective on critical clearing time for wind turbine systems.The stability boundary is verified using time-domain simulation studies. 展开更多
关键词 Lyapunov direct method non-autonomous system phase-locked loop(PLL) time trajectory reversal transient stability assessment wind turbine converter system
原文传递
An Intelligent Coordinated Protection and Control Strategy for Distribution Network with Wind Generation Integration 被引量:5
3
作者 Zhou Liu Hans Kr.Høidalen Murari Mohan Saha 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第4期23-30,共8页
Integration of distributed generation(DG)can change the fault current level and direction in the distribution system,which affects the related protection system.In order to limit the negative impact of DG integration ... Integration of distributed generation(DG)can change the fault current level and direction in the distribution system,which affects the related protection system.In order to limit the negative impact of DG integration and upgrade the protection system performance,an intelligent coordinated protection and control strategy is proposed.A cost based optimization method is adopted to minimize the operation costs of possible solutions.Its aim is to define the optimal relay settings for the present operation condition,and the most suitable control mode of converter based wind turbine DG.Case studies on a hardware in the loop real time simulation platform demonstrate the proposed protection strategy. 展开更多
关键词 converter based wind turbine DG coordinated protection and control hardware in the loop real time simulation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部