An analytic electromagnetic calculation method for performance evolution of doubly fed induction generators for wind turbines 被引量:1
1
作者 张文娟 黄守道 +1 位作者 高剑 CHEN Zhe 《Journal of Central South University》 SCIE EI CAS 2013年第10期2763-2774,共12页
An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of D... An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of DFIG, the modeling for electromagnetic calculation of DFIG was proposed. The electromagnetic calculation of DFIG was divided into three steps: the magnetic flux calculation, parameters derivation and performance checks. For each step, the detailed numeric calculation formulas were all derived. Combining the calculation formulas, the whole electromagnetic calculation procedure was established, which consisted of three iterative calculation loops, including magnetic saturation coefficient, electromotive force and total output power. All of the electromagnetic and performance data of DIFG can be calculated conveniently by the established calculation procedure, which can be used to evaluate the new designed machine. A 1.5 MW DFIG designed by the proposed procedure was built, for which the whole type tests including no-load test, load test and temperature rising test were carried out. The test results have shown that the DFIG satisfies technical requirements and the test data fit well with the calculation results which prove the correctness of the presented calculation method. 展开更多
关键词 ELECTROMAGNETIC calculation doubly fed induction generator(DFIG) wind turbine
下载PDF
Effects of Wind Turbines Equipped with Doubly-fed Induction Generators on Distance Protection 被引量:1
2
作者 Hossein Kazemi KAREGAR Maryam KHODDAM 《电力系统自动化》 EI CSCD 北大核心 2012年第8期128-131,共4页
Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipp... Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied. 展开更多
关键词 距离保护 双馈异步发电机 风力发电机组 配备 可再生能源资源 双馈感应发电机 距离继电器 同步发电机
下载PDF
Reactive Current Allocation and Control Strategies Improvement of Low Voltage Ride Though for Doubly Fed Induction Wind Turbine Generation System 被引量:36
3
作者 LI Hui FU Bo +2 位作者 YANG Chao ZHAO Bin TANG Xianhu 《中国电机工程学报》 EI CSCD 北大核心 2012年第22期I0004-I0004,22,共1页
为满足风电机组低电压穿越(low voltage ride through,LVRT)的测试要求及其电气模型一致性评估需要,提出考虑向电网注入无功电流的双馈风电机组LVRT的控制策略。在阐述风电机组LVRT测试要求及控制原理的基础上,推导双馈发电机(doubly... 为满足风电机组低电压穿越(low voltage ride through,LVRT)的测试要求及其电气模型一致性评估需要,提出考虑向电网注入无功电流的双馈风电机组LVRT的控制策略。在阐述风电机组LVRT测试要求及控制原理的基础上,推导双馈发电机(doubly fed induction generator,DFIG)定子侧及网侧变流器输出无功电流极限表达式,研究电网电压跌落深度和发电机总输出有功功率对其无功电流极限值的影响规律,进而提出DFIG在LVRT期间的无功电流分配算法和改进的有功、无功功率控制策略。最后,以某实际2 MW双馈风电机组为例,分别对风速为5和12 m/s、电网电压对称跌落至20%和50%工况下的LVRT运行性能进行仿真比较和样机测试。与传统LVRT控制方法的对比表明,所提改进控制策略能更好地满足风电机组LVRT的测试要求。样机测试结果进一步证明了改进控制策略和仿真模型的有效性。 展开更多
关键词 风力涡轮机 发电系统 控制策略 无功电流 分配算法 低电压 异步 双馈
下载PDF
High Voltage Ride-through Control Strategy of Doubly Fed Induction Wind Generators Based on Virtual Impedance 被引量:2
4
作者 XIE Zhen ZHANG Xing YANG Shuying SONG Haihua QU Tingyu 《中国电机工程学报》 EI CSCD 北大核心 2012年第27期I0001-I0001,共1页
关键词 双馈感应发电机 风力发电机组 高电压 虚拟阻抗 控制策略 电网干扰 异步 无功补偿装置
下载PDF
Research on multi-time scale doubly-fed wind turbine test system based on FPGA+CPU heterogeneous calculation
5
作者 Qing Mu Xing Zhang +3 位作者 Xiaoxin Zhou Xiaowei Fan Yingmei Liu Dongbo Pan 《Global Energy Interconnection》 2019年第1期7-18,共12页
As the proportion of renewable energy increases, the interaction between renewable energy devices and the grid continues to enhance. Therefore, the renewable energy dynamic test in a power system has become more and m... As the proportion of renewable energy increases, the interaction between renewable energy devices and the grid continues to enhance. Therefore, the renewable energy dynamic test in a power system has become more and more important. Traditional dynamic simulation systems and digital-analog hybrid simulation systems are difficult to compromise on the economy, flexibility and accuracy. A multi-time scale test system of doubly fed induction generator based on FPGA+ CPU heterogeneous calculation is proposed in this paper. The proposed test system is based on the ADPSS simulation platform. The power circuit part of the test system is setup up using the EMT(electromagnetic transient simulation) simulation, and the control part uses the actual physical devices. In order to realize the close-loop testing for the physical devices, the power circuit must be simulated in real-time. This paper proposes a multi-time scale simulation algorithm, in which the decoupling component divides the power circuit into a large time scale system and a small time scale system in order to reduce computing effort. This paper also proposes the FPGA+CPU heterogeneous computing architecture for implementing this multitime scale simulation. In FPGA, there is a complete small time-scale EMT engine, which support the flexibly circuit modeling with any topology. Finally, the test system is connected to an DFIG controller based on Labview to verify the feasibility of the test system. 展开更多
关键词 Renewable energy gen erati on doubly fed in duction generator ADPSS simulati on SYSTEM wind turbine test SYSTEM Multi-time scale FPGA+CPU
下载PDF
A Novel Grid Synchronization Control of Doubly-fed Induction Generator
6
作者 ZHAN Liang-yu JIN Xin-min ZHANG Lu 《电力电子技术》 CSCD 北大核心 2012年第4期38-42,共5页
The dynamic performance of doubly-fed induction generator(DFIG) before and after connection is analyzed based on corresponding mathematical models and transfer functions in decoupled vector control.The parameter tunin... The dynamic performance of doubly-fed induction generator(DFIG) before and after connection is analyzed based on corresponding mathematical models and transfer functions in decoupled vector control.The parameter tuning methods of rotor current regulator before and after connection are given.To reach same dynamic performance the parameters should take different values and be switched before and after connection.However on one hand the closing moment of stator contactor is difficult to get as the feedback signal is usually twenty millisecond delay or so.The delay in parameter switching will affect rotor current and torque dynamics during the delayed period after connection. On the other hand parameter switching is troublesome.Hence a synchronization control strategy without parameter switching is proposed and analyzed in detail,which has linear rising exciting current to avoid current overshooting. The dynamic performance of the proposed strategy is analyzed in frequency domain and implemented on a DFIG experimental platform subsequently.The proposed synchronization strategy is validated by experimental results. 展开更多
关键词 摘要 编辑部 编辑工作 读者
下载PDF
Dynamic modelling and robust current control of wind-turbine driven DFIG during external AC voltage dip 被引量:10
7
作者 HU Jia-bing HE Yi-kang 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第10期1757-1764,共8页
Doubly-Fed Induction Generator (DFIG), with vector control applied, is widely used in Variable-Speed Constant- Frequency (VSCF) wind energy generation system and shows good performance in maximum wind energy capture. ... Doubly-Fed Induction Generator (DFIG), with vector control applied, is widely used in Variable-Speed Constant- Frequency (VSCF) wind energy generation system and shows good performance in maximum wind energy capture. But in two traditional vector control schemes, the equivalent stator magnetizing current is considered invariant in order to simplify the rotor current inner-loop controller. The two schemes can perform very well when the grid is in normal condition. However, when grid disturbance such as grid voltage dip or swell fault occurs, the control performance worsens, the rotor over current occurs and the Fault Ride-Through (FRT) capability of the DFIG wind energy generation system gets seriously deteriorated. An accurate DFIG model was used to deeply investigate the deficiency of the traditional vector control. The improved control schemes of two typical traditional vector control schemes used in DFIG were proposed, and simulation study of the proposed and traditional control schemes, with robust rotor current control using Internal Model Control (IMC) method, was carried out. The validity of the pro- posed modified schemes to control the rotor current and to improve the FRT capability of the DFIG wind energy generation system was proved by the comparison study. 展开更多
关键词 风能 风力发电机 VSCF DFIG FRT 模型控制
下载PDF
Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions 被引量:2
8
作者 Jia-bing HU Yi-kang HE Lie XU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第12期1731-1740,共10页
This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positiv... This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positive and negative synchronous reference frames is presented. Variations of the stator output active and reactive powers are fully deduced in the presence of negative sequence supply voltage and rotor flux. An enhanced DPC scheme is proposed to eliminate stator active power oscillation during network unbalance. The proposed control scheme removes rotor current regulators and the decomposition processing of positive and negative sequence rotor currents. Simulation results using PSCAD/EMTDC are presented on a 2-MW DFIG wind power generation system to validate the feasibility of the proposed control scheme under balanced and unbalanced network conditions. 展开更多
关键词 感应发电机 风涡轮 直流功率控制 定子电压
下载PDF
A Sliding Mode Approach to Enhance the Power Quality of Wind Turbines Under Unbalanced Voltage Conditions 被引量:2
9
作者 Mohammad Javad Morshed Afef Fekih 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第2期566-574,共9页
An integral terminal sliding mode-based control design is proposed in this paper to enhance the power quality of wind turbines under unbalanced voltage conditions. The design combines the robustness, fast response, an... An integral terminal sliding mode-based control design is proposed in this paper to enhance the power quality of wind turbines under unbalanced voltage conditions. The design combines the robustness, fast response, and high quality transient characteristics of the integral terminal sliding mode control with the estimation properties of disturbance observers. The controller gains were auto-tuned using a fuzzy logic approach.The effectiveness of the proposed design was assessed under deep voltage sag conditions and parameter variations. Its dynamic response was also compared to that of a standard SMC approach.The performance analysis and simulation results confirmed the ability of the proposed approach to maintain the active power,currents, DC-link voltage and electromagnetic torque within their acceptable ranges even under the most severe unbalanced voltage conditions. It was also shown to be robust to uncertainties and parameter variations, while effectively mitigating chattering in comparison with the standard SMC. 展开更多
关键词 doubly fed induction generators(DFIG) fuzzy approach integral terminal sliding mode control(ITSMC) OBSERVER power quality voltage unbalances wind turbines
下载PDF
Fractional-Order Control of a Wind Turbine Using Manta Ray Foraging Optimization 被引量:2
10
作者 Hegazy Rezk Mohammed Mazen Alhato +1 位作者 Mohemmed Alhaider Soufiene Bouallègue 《Computers, Materials & Continua》 SCIE EI 2021年第7期185-199,共15页
In this research paper,an improved strategy to enhance the performance of the DC-link voltage loop regulation in a Doubly Fed Induction Generator(DFIG)based wind energy system has been proposed.The proposed strategy u... In this research paper,an improved strategy to enhance the performance of the DC-link voltage loop regulation in a Doubly Fed Induction Generator(DFIG)based wind energy system has been proposed.The proposed strategy used the robust Fractional-Order(FO)Proportional-Integral(PI)control technique.The FOPI control contains a non-integer order which is preferred over the integer-order control owing to its benefits.It offers extra flexibility in design and demonstrates superior outcomes such as high robustness and effectiveness.The optimal gains of the FOPI controller have been determined using a recent Manta Ray Foraging Optimization(MRFO)algorithm.During the optimization process,the FOPI controller’s parameters are assigned to be the decision variables whereas the objective function is the error racking that to be minimized.To prove the superiority of the MRFO algorithm,an empirical comparison study with the homologous particle swarm optimization and genetic algorithm is achieved.The obtained results proved the superiority of the introduced strategy in tracking and control performances against various conditions such as voltage dips and wind speed variation. 展开更多
关键词 Renewable energy MODELING wind turbine doubly fed induction generator fractional order control manta ray foraging optimization
下载PDF
Second-order Sliding Mode Control of DFIG Based Variable Speed Wind Turbine for Maximum Power Point Tracking 被引量:4
11
作者 Xiangjie Liu Chengcheng Wang Yaozhen Han 《自动化学报》 EI CSCD 北大核心 2017年第8期1434-1442,共9页
关键词 风力发电机组 滑模控制器 二阶滑模 变速恒频 最大功率点跟踪 双馈感应发电机 李雅普诺夫函数 发电机转子
下载PDF
Robust nonlinear controller design of wind turbine with doubly fed induction generator by using Hamiltonian energy approach 被引量:1
12
作者 Bing WANG Yanping QIAN Yiming ZHANG 《控制理论与应用(英文版)》 EI CSCD 2013年第2期282-287,共6页
Based on Hamiltonian energy theory, this paper proposes a robust nonlinear controller for the wind turbine with doubly fed induction generator (DFIG), such that the closed-loop system can achieve its stability. Furt... Based on Hamiltonian energy theory, this paper proposes a robust nonlinear controller for the wind turbine with doubly fed induction generator (DFIG), such that the closed-loop system can achieve its stability. Furthermore, in the presence of disturbances, the closed-loop system is finite-gain L2 stable by the Hamiltonian controller. The Hamiltonian energy approach provides us a physical insight and gives a new way to the controller design. The simulation results illustrate that the proposed method is effective and has its advantage. 展开更多
关键词 Hamiltonian energy theory wind turbine doubly fed induction generator Robust control
原文传递
Analysis of Short-circuit Characteristics and Calculation of Steady-state Short-circuit Current for DFIG Wind Turbine 被引量:1
13
作者 Xiong, Xiaofu Ouyang, Jinxin 《电力系统自动化》 EI CSCD 北大核心 2012年第8期115-121,共7页
Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required to remain grid-connection during faults,the short-circuit current contributed by the generation has become a signifi... Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required to remain grid-connection during faults,the short-circuit current contributed by the generation has become a significant issue.However,the traditional calculation methods aiming at synchronous generators cannot be directly applied to the DFIG wind turbines.A new method is needed to calculate the short-circuit current required by the planning,protection and control of the power grid.The short-circuit transition of DFIG under symmetrical and asymmetric short-circuit conditions are mathematically deduced,and the short-circuit characteristics of DFIG are analyzed.A new method is proposed to calculate the steady-state short-circuit current of DFIG based on the derived expressions.The time-domain simulations are conducted to verify the accuracy of the proposed method. 展开更多
关键词 双馈风力发电机 短路电流 短路特性 计算 变速恒频 稳态 双馈感应发电机 非对称短路
下载PDF
PI-MPC Frequency Control of Power System in the Presence of DFIG Wind Turbines 被引量:1
14
作者 Michael Z. Bernard T. H. Mohamed +2 位作者 Raheel Ali Yasunori Mitani Yaser Soliman Qudaih 《Engineering(科研)》 2013年第9期43-50,共8页
For the recent expansion of renewable energy applications, Wind Energy System (WES) is receiving much interest all over the world. However, area load change and abnormal conditions lead to mismatches in frequency and ... For the recent expansion of renewable energy applications, Wind Energy System (WES) is receiving much interest all over the world. However, area load change and abnormal conditions lead to mismatches in frequency and scheduled power interchanges between areas. These mismatches have to be corrected by the LFC system. This paper, therefore, proposes a new robust frequency control technique involving the combination of conventional Proportional-Integral (PI) and Model Predictive Control (MPC) controllers in the presence of wind turbines (WT). The PI-MPC technique has been designed such that the effect of the uncertainty due to governor and turbine parameters variation and load disturbance is reduced. A frequency response dynamic model of a single-area power system with an aggregated generator unit is introduced, and physical constraints of the governors and turbines are considered. The proposed technique is tested on the single-area power system, for enhancement of the network frequency quality. The validity of the proposed method is evaluated by computer simulation analyses using Matlab Simulink. The results show that, with the proposed PI-MPC combination technique, the overall closed loop system performance demonstrated robustness regardless of the presence of uncertainties due to variations of the parameters of governors and turbines, and loads disturbances. A performance comparison between the proposed control scheme, the classical PI control scheme and the MPC is carried out confirming the superiority of the proposed technique in presence of doubly fed induction generator (DFIG) WT. 展开更多
关键词 doubly fed induction generator Power SYSTEM Model PREDICTIVE Control) Proportional Integral Controller DFIG wind turbine wind Energy SYSTEM (WES)
下载PDF
Analysis on Effect of Parameters of Different Wind Generator on Power Grid Transient Stability
15
作者 Zhi-wei Wen Li Ding Shi-en He 《Energy and Power Engineering》 2013年第4期363-367,共5页
To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different... To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different wind farm integration on grid typically in China has been presented. The influence of the variations of transient reactance, negative sequence reactance and rotary inertia on critical clearing time of power system transient stability is analyzed by time-domain simulation. Mixture operation of DFIG and PMSG to optimize the stability of system has been analyzed firstly. The digital simulation results show that doubly-fed induction wind turbines is a better choice to meet the requirement of system instability due to large wind farm integration in comparison with direct-drive PM synchronous wind turbines. With a rather large rotary inertia, the proper ratio of direct-drive PM synchronous wind turbines used in wind farm could be comprehensive planning by optimized the stability of system. Analysis of this paper should be provided as academic reference for improving design of wind farm system. 展开更多
关键词 wind FARM doubly-fed induction generator DIRECT-DRIVE PM SYNCHRONOUS generator Parameter
下载PDF
Fault Ride-Through Study of Wind Turbines
16
作者 Xinyan Zhang Xuan Cao +1 位作者 Weiqing Wang Chao Yun 《Journal of Power and Energy Engineering》 2013年第5期25-29,共5页
The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT ope... The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT operation of the wind farms, three methods were discussed. First, the rotor short current of doubly-fed induction generator (DFIG) was limited by introducing a rotor side protection circuit. Second, the voltage of DC bus was limited by a DC energy absorb circuit. Third, STATCOM was used to increase the low level voltages of the wind farm. Simulation under MATLAB was studied and the corresponding results were given and discussed. The methods proposed in this paper can limit the rotor short current and the DC voltage of the DFIG WT to some degree, but the voltage support to the power system during the fault largely depend on the installation place of STATCOM. 展开更多
关键词 wind Energy FAULT Ride-Through doubly-fed induction generator wind FARM
下载PDF
Layered Multi-mode Optimal Control Strategy for Multi-MW Wind Turbine
17
作者 孔屹刚 王志新 《Journal of Donghua University(English Edition)》 EI CAS 2008年第3期317-323,共7页
The control strategy is one of the most important renewable technology,and an increasing number of multi-MW wind turbines are being developed with a variable speed-variable pitch(VS-VP)technology.The main objective of... The control strategy is one of the most important renewable technology,and an increasing number of multi-MW wind turbines are being developed with a variable speed-variable pitch(VS-VP)technology.The main objective of adopting a VS-VP technology is to improve the fast response speed and capture maximum energy.But the power generated by wind turbine changes rapidly because of the continuous fluctuation of wind speed and direction.At the same time,wind energy conversion systems are of high order,time delays and strong nonlinear characteristics because of many uncertain factors.Based on analyzing the all dynamic processes of wind turbine,a kind of layered multi-mode optimal control strategy is presented which is that three control strategies:bang-bang,fuzzy and adaptive proportional integral derivative(PID)are adopted according to different stages and expected performance of wind turbine to capture optimum wind power,compensate the nonlinearity and improve the wind turbine performance at low,rated and high wind speed. 展开更多
关键词 风力发电机 风能发电 技术性能 资源利用
下载PDF
Coordination between Fault-Ride-Through Capability and Over-current Protection of DFIG Generators for Wind Farms
18
作者 B. Bak-Jensen T.A. Kawady M.H. Abdel-Rahman 《Journal of Energy and Power Engineering》 2010年第4期20-29,共10页
关键词 过电流保护 双馈发电机 通过能力 故障期 风电场 Simulink 风力发电场 风力发电机组
下载PDF
基于传递函数分析的双馈风力发电系统动态建模方法研究
19
作者 夏越 张鸿飞 +4 位作者 陈颖 杜松怀 苏娟 刘露 沈沉 《中国电机工程学报》 EI CSCD 北大核心 2024年第12期4759-4774,I0013,共17页
以双馈风力发电系统(doubly-fed induction generator based wind energy conversion system,DFIG-based WECS)为例,利用小信号分析法推导出由风机、双质量块传动链构成的动力与传动系统通用传递函数方程。动力与传动系统传递函数的零... 以双馈风力发电系统(doubly-fed induction generator based wind energy conversion system,DFIG-based WECS)为例,利用小信号分析法推导出由风机、双质量块传动链构成的动力与传动系统通用传递函数方程。动力与传动系统传递函数的零极点位置、稳定性与系统参数及系统运行工作点相关。该传递函数可进一步分解为扭转分量和非扭转分量。传动链参数仅对扭转分量造成影响。在此基础上,建立了考虑动力传动、电机、变流器、控制等环节的风力发电系统传递函数模型。模型综合了各环节参数,可直观反映系统参数对系统响应的影响,有助于深入了解系统动态行为。算例及时域仿真结果证明了所提出传递函数模型的准确性和高效性,可为系统参数设计研究提供理论依据。 展开更多
关键词 传递函数 双馈风力发电系统(DFIG-based WECS) 小信号分析 动力传动系统模型
下载PDF
计及低电压穿越及故障全过程动态的双馈风电场等值方法
20
作者 周海强 崔晓丹 +3 位作者 许剑冰 曹博源 高超 陈志昊 《电力系统自动化》 EI CSCD 北大核心 2024年第6期216-225,共10页
在分析双馈感应发电机(DFIG)故障各阶段动态的基础上,提出了一种计及低电压穿越控制的双馈风电场等值方法。首先,讨论了低电压穿越控制策略,给出了含双馈风电场的电力系统故障稳态潮流计算方法。在考虑电压暂态过程的条件下,分析了外部... 在分析双馈感应发电机(DFIG)故障各阶段动态的基础上,提出了一种计及低电压穿越控制的双馈风电场等值方法。首先,讨论了低电压穿越控制策略,给出了含双馈风电场的电力系统故障稳态潮流计算方法。在考虑电压暂态过程的条件下,分析了外部系统短路故障后DFIG转子电流的变化机理,指出电压跌落深度及风电功率是影响短路电流的主要因素,可根据动作分界线判断撬棒是否动作。然后,根据初始风速及撬棒状态将风电场中的DFIG分为3群,并对等值DFIG及集电网络进行聚合。为提高等值模型在恢复阶段的精度,根据故障稳态电压对双馈风电场功率恢复曲线进行预估,并在此基础上对等值DFIG恢复速率进行分段修正。最后,对含双馈风电场的算例系统进行了等值计算。仿真结果表明,等值模型较好地保持了原系统在故障各阶段的动态,在保持较高精度的前提下有效简化了系统,提高了计算速度。 展开更多
关键词 双馈感应发电机 风电场 低电压穿越 电力潮流 撬棒 动态等值 等值模型 功率恢复
下载PDF