期刊文献+
共找到2,552篇文章
< 1 2 128 >
每页显示 20 50 100
Dual-negative-objective Coordinated Control of Brushless Doubly Fed Induction Generator under Unbalanced Grid Voltage
1
作者 Ming Cheng Zheng Cao Xiaoming Yan 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第3期347-355,共9页
This article proposes a dual-negative-objective coordinated control strategy for brushless doubly fed induction generator(BDFIG)based wind power generation system under unbalanced grid voltage.To alleviate the mechani... This article proposes a dual-negative-objective coordinated control strategy for brushless doubly fed induction generator(BDFIG)based wind power generation system under unbalanced grid voltage.To alleviate the mechanical stress and impaction on rotating shaft,the negative control objective(NCO)of machine side converter(MSC)is set to suppress the ripple of electromagnetic torque.While the NCO of grid side converter(GSC)is selected to suppress the oscillation of total output active power or the unbalanced degree of total output current for BDFIG generation system.In comparison with traditional single converter control scheme of the MSC or GSC,dual NCOs can be satisfied at the same time due to the enlarged freedom degree in the proposed improved coordinated control system for back-toback converters.The effectiveness of proposed control strategy is validated by simulation and experimental results on a dual-cagerotor BDFIG(DCR-BDFIG)prototype. 展开更多
关键词 Brushless doubly fed induction generator Dual-negative-objective Freedom degree Unbalanced grid voltage
下载PDF
Robust nonlinear controller design of wind turbine with doubly fed induction generator by using Hamiltonian energy approach 被引量:1
2
作者 Bing WANG Yanping QIAN Yiming ZHANG 《控制理论与应用(英文版)》 EI CSCD 2013年第2期282-287,共6页
Based on Hamiltonian energy theory, this paper proposes a robust nonlinear controller for the wind turbine with doubly fed induction generator (DFIG), such that the closed-loop system can achieve its stability. Furt... Based on Hamiltonian energy theory, this paper proposes a robust nonlinear controller for the wind turbine with doubly fed induction generator (DFIG), such that the closed-loop system can achieve its stability. Furthermore, in the presence of disturbances, the closed-loop system is finite-gain L2 stable by the Hamiltonian controller. The Hamiltonian energy approach provides us a physical insight and gives a new way to the controller design. The simulation results illustrate that the proposed method is effective and has its advantage. 展开更多
关键词 Hamiltonian energy theory wind turbine doubly fed induction generator Robust control
原文传递
Effects of Wind Turbines Equipped with Doubly-fed Induction Generators on Distance Protection 被引量:1
3
作者 Hossein Kazemi KAREGAR Maryam KHODDAM 《电力系统自动化》 EI CSCD 北大核心 2012年第8期128-131,共4页
Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipp... Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied. 展开更多
关键词 距离保护 双馈异步发电机 风力发电机组 配备 可再生能源资源 双馈感应发电机 距离继电器 同步发电机
下载PDF
An analytic electromagnetic calculation method for performance evolution of doubly fed induction generators for wind turbines 被引量:1
4
作者 张文娟 黄守道 +1 位作者 高剑 CHEN Zhe 《Journal of Central South University》 SCIE EI CAS 2013年第10期2763-2774,共12页
An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of D... An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of DFIG, the modeling for electromagnetic calculation of DFIG was proposed. The electromagnetic calculation of DFIG was divided into three steps: the magnetic flux calculation, parameters derivation and performance checks. For each step, the detailed numeric calculation formulas were all derived. Combining the calculation formulas, the whole electromagnetic calculation procedure was established, which consisted of three iterative calculation loops, including magnetic saturation coefficient, electromotive force and total output power. All of the electromagnetic and performance data of DIFG can be calculated conveniently by the established calculation procedure, which can be used to evaluate the new designed machine. A 1.5 MW DFIG designed by the proposed procedure was built, for which the whole type tests including no-load test, load test and temperature rising test were carried out. The test results have shown that the DFIG satisfies technical requirements and the test data fit well with the calculation results which prove the correctness of the presented calculation method. 展开更多
关键词 ELECTROMAGNETIC calculation doubly fed induction generator(DFIG) wind turbine
下载PDF
Reactive Current Allocation and Control Strategies Improvement of Low Voltage Ride Though for Doubly Fed Induction Wind Turbine Generation System 被引量:36
5
作者 LI Hui FU Bo +2 位作者 YANG Chao ZHAO Bin TANG Xianhu 《中国电机工程学报》 EI CSCD 北大核心 2012年第22期I0004-I0004,22,共1页
为满足风电机组低电压穿越(low voltage ride through,LVRT)的测试要求及其电气模型一致性评估需要,提出考虑向电网注入无功电流的双馈风电机组LVRT的控制策略。在阐述风电机组LVRT测试要求及控制原理的基础上,推导双馈发电机(doubly... 为满足风电机组低电压穿越(low voltage ride through,LVRT)的测试要求及其电气模型一致性评估需要,提出考虑向电网注入无功电流的双馈风电机组LVRT的控制策略。在阐述风电机组LVRT测试要求及控制原理的基础上,推导双馈发电机(doubly fed induction generator,DFIG)定子侧及网侧变流器输出无功电流极限表达式,研究电网电压跌落深度和发电机总输出有功功率对其无功电流极限值的影响规律,进而提出DFIG在LVRT期间的无功电流分配算法和改进的有功、无功功率控制策略。最后,以某实际2 MW双馈风电机组为例,分别对风速为5和12 m/s、电网电压对称跌落至20%和50%工况下的LVRT运行性能进行仿真比较和样机测试。与传统LVRT控制方法的对比表明,所提改进控制策略能更好地满足风电机组LVRT的测试要求。样机测试结果进一步证明了改进控制策略和仿真模型的有效性。 展开更多
关键词 风力涡轮机 发电系统 控制策略 无功电流 分配算法 低电压 异步 双馈
下载PDF
High Voltage Ride-through Control Strategy of Doubly Fed Induction Wind Generators Based on Virtual Impedance 被引量:2
6
作者 XIE Zhen ZHANG Xing YANG Shuying SONG Haihua QU Tingyu 《中国电机工程学报》 EI CSCD 北大核心 2012年第27期I0001-I0001,共1页
关键词 双馈感应发电机 风力发电机组 高电压 虚拟阻抗 控制策略 电网干扰 异步 无功补偿装置
下载PDF
Isolated MicroGrid’s Voltage and Frequency Characteristic with Induction Generator Based Wind Turbine 被引量:1
7
作者 Woo-Kyu Chae Hak-Ju Lee +2 位作者 Sung-Wook Hwang Il-Keun Song Jae-Eon Kim 《Smart Grid and Renewable Energy》 2014年第7期180-192,共13页
To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery sys... To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery system, back-up diesel generator, etc., Isolated MicroGrid, which usually uses the inverter to maintain voltage and frequency of the system, is very weak in terms of voltage and frequency stability compared to the large-scale electrical power system. If wind turbine generator is applied to this weak power system, it could experience many problems in terms of maintaining its voltage and frequency. In this paper, the measurement result of voltage and frequency is presented for MicroGrid, which consists of the Wind Turbine Generator adopting the induction generator and the battery system. MicroGrid’s voltage waveform distortion and Wind Turbine Generator’s output oscillation problems are analyzed using PSCAD/EMTDC. Based on the analyzed result, the importance of type and capacity choice has been suggested in case the Wind Turbine Generator is applied to the Isolated MicroGrid. 展开更多
关键词 MICROGRID wind turbine induction generator Battery VOLTAGE Frequency PSCAD/EMTDC
下载PDF
A Gain Scheduled Method for Speed Control of Wind Driven Doubly Fed Induction Generator
8
作者 Wei Wang Kang-Zhi Liu Tadanao Zanma 《Engineering(科研)》 2013年第1期89-95,共7页
This paper proposes a gain scheduled control method for a doubly fed induction generator driven by a wind turbine. The purpose is to design a variable speed control system so as to extract the maximum power in the reg... This paper proposes a gain scheduled control method for a doubly fed induction generator driven by a wind turbine. The purpose is to design a variable speed control system so as to extract the maximum power in the region below the rated wind speed. Gain scheduled control approach is applied in order to achieve high performance over a wide range of wind speed. A double loop configuration is adopted. In the inner loop, the rotor speed is used as the scheduling parameter, while a function of wind and rotor speed is used as the scheduling parameter in the outer loop. It is verified in simulations that a high tracking performance has been achieved. 展开更多
关键词 doubly fed induction generator GAIN scheduled CONTROL METHOD speed CONTROL current CONTROL
下载PDF
A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support
9
作者 沈阳武 柯德平 +3 位作者 孙元章 Daniel Kirschen 王轶申 胡元朝 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期52-63,共12页
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient volt... A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. 展开更多
关键词 doubly-fed induction generator transient rotor current control superconducting magnetic energy storage voltage support
下载PDF
Research on multi-time scale doubly-fed wind turbine test system based on FPGA+CPU heterogeneous calculation
10
作者 Qing Mu Xing Zhang +3 位作者 Xiaoxin Zhou Xiaowei Fan Yingmei Liu Dongbo Pan 《Global Energy Interconnection》 2019年第1期7-18,共12页
As the proportion of renewable energy increases, the interaction between renewable energy devices and the grid continues to enhance. Therefore, the renewable energy dynamic test in a power system has become more and m... As the proportion of renewable energy increases, the interaction between renewable energy devices and the grid continues to enhance. Therefore, the renewable energy dynamic test in a power system has become more and more important. Traditional dynamic simulation systems and digital-analog hybrid simulation systems are difficult to compromise on the economy, flexibility and accuracy. A multi-time scale test system of doubly fed induction generator based on FPGA+ CPU heterogeneous calculation is proposed in this paper. The proposed test system is based on the ADPSS simulation platform. The power circuit part of the test system is setup up using the EMT(electromagnetic transient simulation) simulation, and the control part uses the actual physical devices. In order to realize the close-loop testing for the physical devices, the power circuit must be simulated in real-time. This paper proposes a multi-time scale simulation algorithm, in which the decoupling component divides the power circuit into a large time scale system and a small time scale system in order to reduce computing effort. This paper also proposes the FPGA+CPU heterogeneous computing architecture for implementing this multitime scale simulation. In FPGA, there is a complete small time-scale EMT engine, which support the flexibly circuit modeling with any topology. Finally, the test system is connected to an DFIG controller based on Labview to verify the feasibility of the test system. 展开更多
关键词 Renewable energy gen erati on doubly fed in duction generator ADPSS simulati on SYSTEM wind turbine test SYSTEM Multi-time scale FPGA+CPU
下载PDF
A Novel Grid Synchronization Control of Doubly-fed Induction Generator
11
作者 ZHAN Liang-yu JIN Xin-min ZHANG Lu 《电力电子技术》 CSCD 北大核心 2012年第4期38-42,共5页
The dynamic performance of doubly-fed induction generator(DFIG) before and after connection is analyzed based on corresponding mathematical models and transfer functions in decoupled vector control.The parameter tunin... The dynamic performance of doubly-fed induction generator(DFIG) before and after connection is analyzed based on corresponding mathematical models and transfer functions in decoupled vector control.The parameter tuning methods of rotor current regulator before and after connection are given.To reach same dynamic performance the parameters should take different values and be switched before and after connection.However on one hand the closing moment of stator contactor is difficult to get as the feedback signal is usually twenty millisecond delay or so.The delay in parameter switching will affect rotor current and torque dynamics during the delayed period after connection. On the other hand parameter switching is troublesome.Hence a synchronization control strategy without parameter switching is proposed and analyzed in detail,which has linear rising exciting current to avoid current overshooting. The dynamic performance of the proposed strategy is analyzed in frequency domain and implemented on a DFIG experimental platform subsequently.The proposed synchronization strategy is validated by experimental results. 展开更多
关键词 摘要 编辑部 编辑工作 读者
下载PDF
Robust Optimal Framework for Doubly Fed Induction Generator with Uncertain Dynamics
12
作者 Yongfeng Lü Xiaowei Zhao Priyank Shah 《Protection and Control of Modern Power Systems》 SCIE EI 2024年第5期129-141,共13页
A robust optimal framework is designed herein to mitigate the oscillatory dynamics in a doubly fed induction generator(DFIG)even in the presence of network disturbances and input variation.To address uncertain dynamic... A robust optimal framework is designed herein to mitigate the oscillatory dynamics in a doubly fed induction generator(DFIG)even in the presence of network disturbances and input variation.To address uncertain dynamics,herein,a novel transformation formula is developed for a wind energy conversion system.An unscented Kalman filter is applied to estimate the un-measured internal states of the wind energy conversion system using terminal measurements.The detailed convergence and stability analyses of the presented framework are investigated to validate its effectiveness.Additionally,comparative modal analyses are carried out to demonstrate the improvement in the damping of critical low-frequency oscillatory modes using the presented framework.The simulation results demonstrate satisfactory performance under various operating scenarios,such as increasing and decreasing wind speed and varying the terminal voltage.The comparative performance is demonstrated to validate the effectiveness of the presented framework over that of the state-of-the-art frameworks.Index Terms—Optimal control,power system,renew-able energy sources,wind energy conversion system,doubly fed induction generator. 展开更多
关键词 Optimal control power system renew-able energy sources wind energy conversion system doubly fed induction generator
原文传递
Dynamic Couplingand Cooperative Control for Multi-paralleled Doubly Fed Induction Generator Wind Farms during Symmetrical Low Voltage Ride-through in a Weak Grid
13
作者 Lei Guan Jun Yao 《Protection and Control of Modern Power Systems》 SCIE EI 2024年第3期112-125,共14页
In multi-fed grid-connected systems,there are complex dynamic interactions between different pieces of equipment.Particularly in situations of weak-grid faults,the dynamic coupling between equipment becomes more prono... In multi-fed grid-connected systems,there are complex dynamic interactions between different pieces of equipment.Particularly in situations of weak-grid faults,the dynamic coupling between equipment becomes more pronounced.This may cause the system to experience small-signal instability during the fault steady-state.In this paper,multi-paralleled doubly fed induction generator(DFIG)-based wind farms(WFs)are taken as an example to study the dynamic coupling within a multi-fed system during fault steady-state of symmetrical low voltage ride-through(LVRT)in a weak grid.The analysis reveals that the dynamic coupling between WFs will introduce a damping shift to each WF.This inevitably affects the system’s dynamic stability and brings the risk of small-signal instability during fault steady-state in LVRT scenarios.Increasing the distance to fault location and fault severity will exacerbate the dynamic coupling between WFs.Because of the dynamic coupling,adjusting the control state of one WF will affect the stability of the remaining WFs in the system.Hence,a cooperative control strategy for multi-paralleled DFIG WFs is proposed to improve dynamic stability during LVRT.The analysis and the effectiveness of the proposed control strategy are verified by modal analysis and simu-lation. 展开更多
关键词 doubly fed induction generator(DFIG) wind farms(WFs) dynamic stability low voltage ride through(LVRT) weak grid dynamic coupling
原文传递
A novel control strategy of a variable-speed doubly-fed-induction-generator-based wind energy conversion system
14
作者 Shibani Prasad Mohapatra Pradipta Kishore Dash 《Clean Energy》 EI CSCD 2024年第1期153-170,共18页
This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction g... This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction generator-based variable-speed wind turbine by controlling the rotor current. In the first step, a maximum power point tracking technique is used to extract the maximum power from theturbine. Then a stator-flux-oriented vector control strategy is employed to control the rotor-side current. Subsequently, a grid voltagevector-oriented control strategy is used to control the grid-side system of the grid-connected generator. Considering the nonlinearityand parameter uncertainty of the system, an active disturbance rejection controller with a sliding-mode-based extended-state observeris developed for the above-mentioned control strategies. Furthermore, the stability of the controller is tested and the performance of thecontroller is compared with the classical proportional-integral controller based on disturbance rejection, robustness and tracking capability in a highly non-linear wind speed variation scenario. Modelling, control and comparison are conducted in the MATLAB®/Simulink®environment. Finally, a real-time hardware set-up is presented using the dSPACE ds-1104 R&D processing board to validate the controlscheme. From the result of the experiments, it is seen that the proposed controller takes 10-15 control cycles to settle to its steady-statevalues, depending on the control loop, whereas the conventional proportional-integral controller takes 60-75 control cycles. As a result,the settling time for the proposed control scheme is shorter than that of the proportional-integral controller. 展开更多
关键词 doubly-fed induction generator variable-speed wind turbine vector control active disturbance rejection controller stability analysis
原文传递
Control of Doubly Fed Induction Generator under Unbalanced Voltages for Reduction of Torque Pulsation
15
作者 S. Wangsathitwong S. Sirisumrannukul +1 位作者 S. Chatratana W. Deleroi 《Journal of Energy and Power Engineering》 2011年第3期243-251,共9页
The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is t... The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is the consequence of the interaction of stator and rotor currents of different sequences. This paper presents a control technique to reduce the effect of unbalanced voltages on the DFIG in wind energy conversion systems. The negative sequence stator voltage is derived from the unbalanced three phase stator voltages. The compensated rotor voltage in terms of the derived negative sequence stator voltage and slip which minimizes the negative stator and rotor currents is proposed. The results from the simulation of control system with steady state model and dynamic model of the DFIG show that additional control loop with compensated voltage can significantly reduce torque and reactive power pulsations. 展开更多
关键词 doubly fed induction generator (DFIG) unbalanced voltages symmetrical components.
下载PDF
基于E-Wind Turbine实验平台的风力发电控制系统 被引量:3
16
作者 高哲 汪沛 +1 位作者 赵艳华 刘婷 《实验技术与管理》 CAS 北大核心 2015年第7期91-95,共5页
风力发电系统具有规模大、实际现场培训成本高、危险系数高等特点,因此基于风力发电仿真设备的风力发电控制研究是十分必要的。以E-Wind Turbine实验平台为例,详细介绍了变速、变桨距双馈风力发电系统实验平台的构成与控制策略的实现方... 风力发电系统具有规模大、实际现场培训成本高、危险系数高等特点,因此基于风力发电仿真设备的风力发电控制研究是十分必要的。以E-Wind Turbine实验平台为例,详细介绍了变速、变桨距双馈风力发电系统实验平台的构成与控制策略的实现方法。基于S7-1200系列的PLC控制器,利用PORTAL STEP 7集成开发环境,实现了风机的偏航、转速控制以及功率控制。仿真实验结果表明,设计的风力发电控制系统可以有效地模拟实际风力发电机的各种控制要求,为风力发电控制策略的研究提供了一种有效手段。 展开更多
关键词 双馈风力发电系统 E-wind turbine实验平台 变速变桨距 S7-1200系列PLC
下载PDF
A Sliding Mode Approach to Enhance the Power Quality of Wind Turbines Under Unbalanced Voltage Conditions 被引量:2
17
作者 Mohammad Javad Morshed Afef Fekih 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第2期566-574,共9页
An integral terminal sliding mode-based control design is proposed in this paper to enhance the power quality of wind turbines under unbalanced voltage conditions. The design combines the robustness, fast response, an... An integral terminal sliding mode-based control design is proposed in this paper to enhance the power quality of wind turbines under unbalanced voltage conditions. The design combines the robustness, fast response, and high quality transient characteristics of the integral terminal sliding mode control with the estimation properties of disturbance observers. The controller gains were auto-tuned using a fuzzy logic approach.The effectiveness of the proposed design was assessed under deep voltage sag conditions and parameter variations. Its dynamic response was also compared to that of a standard SMC approach.The performance analysis and simulation results confirmed the ability of the proposed approach to maintain the active power,currents, DC-link voltage and electromagnetic torque within their acceptable ranges even under the most severe unbalanced voltage conditions. It was also shown to be robust to uncertainties and parameter variations, while effectively mitigating chattering in comparison with the standard SMC. 展开更多
关键词 doubly fed induction generators(DFIG) fuzzy approach integral terminal sliding mode control(ITSMC) OBSERVER power quality voltage unbalances wind turbines
下载PDF
Fractional-Order Control of a Wind Turbine Using Manta Ray Foraging Optimization 被引量:2
18
作者 Hegazy Rezk Mohammed Mazen Alhato +1 位作者 Mohemmed Alhaider Soufiene Bouallègue 《Computers, Materials & Continua》 SCIE EI 2021年第7期185-199,共15页
In this research paper,an improved strategy to enhance the performance of the DC-link voltage loop regulation in a Doubly Fed Induction Generator(DFIG)based wind energy system has been proposed.The proposed strategy u... In this research paper,an improved strategy to enhance the performance of the DC-link voltage loop regulation in a Doubly Fed Induction Generator(DFIG)based wind energy system has been proposed.The proposed strategy used the robust Fractional-Order(FO)Proportional-Integral(PI)control technique.The FOPI control contains a non-integer order which is preferred over the integer-order control owing to its benefits.It offers extra flexibility in design and demonstrates superior outcomes such as high robustness and effectiveness.The optimal gains of the FOPI controller have been determined using a recent Manta Ray Foraging Optimization(MRFO)algorithm.During the optimization process,the FOPI controller’s parameters are assigned to be the decision variables whereas the objective function is the error racking that to be minimized.To prove the superiority of the MRFO algorithm,an empirical comparison study with the homologous particle swarm optimization and genetic algorithm is achieved.The obtained results proved the superiority of the introduced strategy in tracking and control performances against various conditions such as voltage dips and wind speed variation. 展开更多
关键词 Renewable energy MODELING wind turbine doubly fed induction generator fractional order control manta ray foraging optimization
下载PDF
Second-order Sliding Mode Control of DFIG Based Variable Speed Wind Turbine for Maximum Power Point Tracking 被引量:4
19
作者 Xiangjie Liu Chengcheng Wang Yaozhen Han 《自动化学报》 EI CSCD 北大核心 2017年第8期1434-1442,共9页
关键词 风力发电机组 滑模控制器 二阶滑模 变速恒频 最大功率点跟踪 双馈感应发电机 李雅普诺夫函数 发电机转子
下载PDF
Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions 被引量:2
20
作者 Jia-bing HU Yi-kang HE Lie XU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第12期1731-1740,共10页
This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positiv... This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positive and negative synchronous reference frames is presented. Variations of the stator output active and reactive powers are fully deduced in the presence of negative sequence supply voltage and rotor flux. An enhanced DPC scheme is proposed to eliminate stator active power oscillation during network unbalance. The proposed control scheme removes rotor current regulators and the decomposition processing of positive and negative sequence rotor currents. Simulation results using PSCAD/EMTDC are presented on a 2-MW DFIG wind power generation system to validate the feasibility of the proposed control scheme under balanced and unbalanced network conditions. 展开更多
关键词 doubly-fed induction generator (DFIG) wind turbine Direct power control (DPC) Stator voltage oriented (SVO) Unbalanced network
下载PDF
上一页 1 2 128 下一页 到第
使用帮助 返回顶部