Due to the intermittency and instability of Wind-Solar energy and easy compensation of hydropower, this study proposes a Wind-Solar-Hydro power optimal scheduling model. This model is aimed at maximizing the total sys...Due to the intermittency and instability of Wind-Solar energy and easy compensation of hydropower, this study proposes a Wind-Solar-Hydro power optimal scheduling model. This model is aimed at maximizing the total system power generation and the minimum ten-day joint output. To effectively optimize the multi-objective model, a new algorithm named non-dominated sorting culture differential evolution algorithm(NSCDE) is proposed. The feasibility of NSCDE was verified through several well-known benchmark problems. It was then applied to the Jinping Wind-Solar-Hydro complementary power generation system. The results demonstrate that NSCDE can provide decision makers a series of optimized scheduling schemes.展开更多
In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the outpu...In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the output becomes unstable because of intermittent characteristics, such as variations of wind speed or solar radiation intensity. Frequency fluctuations due to the installation of large scale wind farm (WF) and photovoltaics (PV) into the power system is a major concern. In order to solve the problem, this paper proposes two control methods using High Voltage Direct Current (HVDC) interconnection line to suppress the frequency fluctuations due to large scale of WF and PV. Comparative analysis between these two control methods is presented in this paper. One proposed method is a frequency control using a notch filter, and the other is using a deadband. Validity of the proposed methods is verified through simulation analyses, which is performed on a multi-machine power system model.展开更多
In order to alleviate environmental pollution of Urumqi,China,a stand-alone hybrid wind / PV / battery power system was studied for this region. An accurate structure and model of the standalone hybrid wind / PV / bat...In order to alleviate environmental pollution of Urumqi,China,a stand-alone hybrid wind / PV / battery power system was studied for this region. An accurate structure and model of the standalone hybrid wind / PV / battery power system for a household in that region was presented in this study. On the basis of wind speed,solar radiation,ambient temperature,and load data,the optimal design of the hybrid system is determined using a genetic algorithm( GA). As a result,the optimal hybrid system for a household consists of one wind turbine,21. 407 6 m^2 of PV arrays,and 20. 958 kW ·h of battery bank capacity. The system has a loss of power supply probability( LPSP) of 0. 019 9 and the minimum total annualized cost is $ 35 333.展开更多
Energy complementarity can be a tool for managers to prioritize investments in new power generation ventures. An index for complementarity assessment should allow comparison of complementarities at different sites. Th...Energy complementarity can be a tool for managers to prioritize investments in new power generation ventures. An index for complementarity assessment should allow comparison of complementarities at different sites. This article proposes a new method for the calculation of complementarity index, allowing the comparison two energy resources and also allowing the comparison of more than two energy resources. In addition, the proposed index still allows the use of hourly or daily series and not only maximum or minimum values. Finally, this article also presents a map for the state of Rio Grande do Sul, the southernmost state of Brazil, indicating the energetic complementarity in time between hydropower, wind energy and PV solar energy.展开更多
随着大量新能源的接入,使得多端柔性直流系统(modular multilevel converter based multi-terminal direct current, MMC-MTDC)故障特征愈加复杂,快速准确的故障识别与测距是亟需解决的关键难题之一。为此,提出了一种风-光-储-蓄互补发...随着大量新能源的接入,使得多端柔性直流系统(modular multilevel converter based multi-terminal direct current, MMC-MTDC)故障特征愈加复杂,快速准确的故障识别与测距是亟需解决的关键难题之一。为此,提出了一种风-光-储-蓄互补发电站经柔性直流输电外送系统故障识别与测距方法。首先,搭建风-光-储-蓄互补发电站经柔直外送系统,在此基础上,提出了一种Teager能量算子能量熵的新方法,利用测量点正负极Teager能量算子能量熵的比值构建故障选极及区段识别判据。接着,针对已识别的故障线路,提出变分模态分解(variational mode decomposition, VMD)与Teager能量算子(teager energy operator, TEO)相结合的故障测距方法。最后,利用PSCAD/EMTDC进行仿真,结果表明所提识别方法可以准确判断故障所在线路,所提测距方法能在故障发生2 ms时间窗内实现故障测距,误差率不超过2.55%,并具有较高的耐过渡电阻能力。展开更多
风光水打捆经电网换相换流器高压直流输电(line commutated converter based high voltage direct current,LCC-HVDC)外送系统中,风光水配比不同会影响系统的功率传输能力。文章首先建立风光水打捆直流外送系统的稳态数学模型和状态空...风光水打捆经电网换相换流器高压直流输电(line commutated converter based high voltage direct current,LCC-HVDC)外送系统中,风光水配比不同会影响系统的功率传输能力。文章首先建立风光水打捆直流外送系统的稳态数学模型和状态空间模型,然后提出综合考虑稳态运行约束条件和小信号稳定性约束条件的系统功率传输能力计算方法及流程,掌握不同功率水平下系统稳定运行区域及边界的变化特征,最终得到不同水电出力下的直流外送系统功率传输范围、特定传输功率下所允许的水电出力最小值、风光配比与小信号稳定性的定量关系。通过该方法定量评估风光水配比不同时直流外送系统的功率传输能力,从而优化选取风光水配比。结果表明,水电出力较小时,系统传输功率上限受小信号稳定性制约,下限受电压偏移约束制约;水电出力较大时,系统传输功率上限受LCC-HVDC安全运行约束制约,下限受逆变侧电压偏移、系统潮流约束制约;在功率运行点不变时,风光配比平衡工况系统更加稳定。最后,通过PSCAD/EMTDC下的电磁暂态仿真,验证上述功率传输能力理论计算的正确性。展开更多
基金supported by the National Key R&D Program of China (2016YFC0402209)the Major Research Plan of the National Natural Science Foundation of China (No. 91647114)
文摘Due to the intermittency and instability of Wind-Solar energy and easy compensation of hydropower, this study proposes a Wind-Solar-Hydro power optimal scheduling model. This model is aimed at maximizing the total system power generation and the minimum ten-day joint output. To effectively optimize the multi-objective model, a new algorithm named non-dominated sorting culture differential evolution algorithm(NSCDE) is proposed. The feasibility of NSCDE was verified through several well-known benchmark problems. It was then applied to the Jinping Wind-Solar-Hydro complementary power generation system. The results demonstrate that NSCDE can provide decision makers a series of optimized scheduling schemes.
文摘In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the output becomes unstable because of intermittent characteristics, such as variations of wind speed or solar radiation intensity. Frequency fluctuations due to the installation of large scale wind farm (WF) and photovoltaics (PV) into the power system is a major concern. In order to solve the problem, this paper proposes two control methods using High Voltage Direct Current (HVDC) interconnection line to suppress the frequency fluctuations due to large scale of WF and PV. Comparative analysis between these two control methods is presented in this paper. One proposed method is a frequency control using a notch filter, and the other is using a deadband. Validity of the proposed methods is verified through simulation analyses, which is performed on a multi-machine power system model.
基金On-Job Doctorate Foundation of Nanjing Institute of Technology,China(No.ZKJ201401)National Natural Science Foundation of China(No.11302097)+1 种基金Postdoctoral Foundation of Jiangsu,China(No.1301060B)Jiangsu Provincial Graduate Student Innovation Project,China(No.CXZZ11_0444)
文摘In order to alleviate environmental pollution of Urumqi,China,a stand-alone hybrid wind / PV / battery power system was studied for this region. An accurate structure and model of the standalone hybrid wind / PV / battery power system for a household in that region was presented in this study. On the basis of wind speed,solar radiation,ambient temperature,and load data,the optimal design of the hybrid system is determined using a genetic algorithm( GA). As a result,the optimal hybrid system for a household consists of one wind turbine,21. 407 6 m^2 of PV arrays,and 20. 958 kW ·h of battery bank capacity. The system has a loss of power supply probability( LPSP) of 0. 019 9 and the minimum total annualized cost is $ 35 333.
文摘Energy complementarity can be a tool for managers to prioritize investments in new power generation ventures. An index for complementarity assessment should allow comparison of complementarities at different sites. This article proposes a new method for the calculation of complementarity index, allowing the comparison two energy resources and also allowing the comparison of more than two energy resources. In addition, the proposed index still allows the use of hourly or daily series and not only maximum or minimum values. Finally, this article also presents a map for the state of Rio Grande do Sul, the southernmost state of Brazil, indicating the energetic complementarity in time between hydropower, wind energy and PV solar energy.
文摘随着大量新能源的接入,使得多端柔性直流系统(modular multilevel converter based multi-terminal direct current, MMC-MTDC)故障特征愈加复杂,快速准确的故障识别与测距是亟需解决的关键难题之一。为此,提出了一种风-光-储-蓄互补发电站经柔性直流输电外送系统故障识别与测距方法。首先,搭建风-光-储-蓄互补发电站经柔直外送系统,在此基础上,提出了一种Teager能量算子能量熵的新方法,利用测量点正负极Teager能量算子能量熵的比值构建故障选极及区段识别判据。接着,针对已识别的故障线路,提出变分模态分解(variational mode decomposition, VMD)与Teager能量算子(teager energy operator, TEO)相结合的故障测距方法。最后,利用PSCAD/EMTDC进行仿真,结果表明所提识别方法可以准确判断故障所在线路,所提测距方法能在故障发生2 ms时间窗内实现故障测距,误差率不超过2.55%,并具有较高的耐过渡电阻能力。
文摘风光水打捆经电网换相换流器高压直流输电(line commutated converter based high voltage direct current,LCC-HVDC)外送系统中,风光水配比不同会影响系统的功率传输能力。文章首先建立风光水打捆直流外送系统的稳态数学模型和状态空间模型,然后提出综合考虑稳态运行约束条件和小信号稳定性约束条件的系统功率传输能力计算方法及流程,掌握不同功率水平下系统稳定运行区域及边界的变化特征,最终得到不同水电出力下的直流外送系统功率传输范围、特定传输功率下所允许的水电出力最小值、风光配比与小信号稳定性的定量关系。通过该方法定量评估风光水配比不同时直流外送系统的功率传输能力,从而优化选取风光水配比。结果表明,水电出力较小时,系统传输功率上限受小信号稳定性制约,下限受电压偏移约束制约;水电出力较大时,系统传输功率上限受LCC-HVDC安全运行约束制约,下限受逆变侧电压偏移、系统潮流约束制约;在功率运行点不变时,风光配比平衡工况系统更加稳定。最后,通过PSCAD/EMTDC下的电磁暂态仿真,验证上述功率传输能力理论计算的正确性。