Microstructure and microhardness of aluminium alloy with underwater and in-air wire-feed laser deposition 被引量:1
1
作者 Ning Guo Qi Cheng +5 位作者 Yunlong Fu Yang Gao Hao Chen Shuai Zhang Xin Zhang Jinlong He 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2023年第4期670-677,共8页
This study carried out the underwater and in-air wire-feed laser deposition of an aluminium alloy with a thin-walled tubular structure. For both the underwater and in-air deposition layers, both were well-formed and i... This study carried out the underwater and in-air wire-feed laser deposition of an aluminium alloy with a thin-walled tubular structure. For both the underwater and in-air deposition layers, both were well-formed and incomplete fusion, cracks, or other defects did not exist.Compared with the single-track deposition layer in air, the oxidation degree of the underwater single-track deposition layer was slightly higher.In both the underwater and in-air deposition layers, columnar dendrites nucleated close to the fusion line and grew along the direction of the maximum cooling rate in the fusion region(FR), while equiaxed grains formed in the deposited region(DR). As the environment changed from air to water, the width of DR and height of FR decreased, but the deposition angle and height of DR increased. The grain size and ratio of the high-angle boundaries also decreased due to the large cooling rate and low peak temperature in the water environment.Besides, the existence of a water environment benefitted the reduction of magnesium element burning loss in the DR. The microhardness values of the underwater deposition layer were much larger than those of the in-air layer, owing to the fine grains and high magnesium content. 展开更多
关键词 wire-feed laser deposition MICROSTRUCTURE magnesium element burn loss MICROHARDNESS
下载PDF
Alterative wire-feed system based on arc voltage negative feedback
2
作者 傅强 薛松柏 《China Welding》 EI CAS 2012年第2期38-42,共5页
Waveform control method was commonly adopted to reduce the spatter of CO2 arc welding and improve the weld formation. It certainly would reduce the self-regulation ability of arc due to the adoption of segmented const... Waveform control method was commonly adopted to reduce the spatter of CO2 arc welding and improve the weld formation. It certainly would reduce the self-regulation ability of arc due to the adoption of segmented constant current control which especially led to arc" blowout with the abrupt change oat" arc" length or downward welding. Therefore alterative wire-feed system based on arc voltage negative feedback was put forward to improve the .stability of arc" length in this paper. Double closed-loop and double fuzzy P1 regulation were adopted in this system. Fuzzy control of induced voltage was adopted in the inner-loop which improved the stability and fast response of wire-feed system. Fuzz)" control of arc" voltage negative feedback was used in the outer-loop whose output .served as the input of negative feedback regulation of inner-loop induced voltage. This method could remain arc" length and weld penetration unchan, ged on the basils of reducing spatter and improving formation and it was proved by downward welding tests. 展开更多
关键词 are voltage negative feedback CO2 are welding waveform control aherative wire-feed system
下载PDF
A novel Ti cored wire developed for wire-feed arc deposition of TiB/Ti composite coating
3
作者 Yang Bao Lujun Huang +5 位作者 Shan Jiang Rui Zhang Qi An Caiwei Zhang Lin Geng Xinxin Ma 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2021年第24期145-160,共16页
A novel Ti cored wire containing Ti B2,Al60 V40 and Ti6 Al4 V mixed powders was developed for wirefeed arc deposition of Ti B/Ti composite coating,to enhance the hardness and wear resistance of Ti alloy.Results showed... A novel Ti cored wire containing Ti B2,Al60 V40 and Ti6 Al4 V mixed powders was developed for wirefeed arc deposition of Ti B/Ti composite coating,to enhance the hardness and wear resistance of Ti alloy.Results showed that after experiencing several chemical reactions,the wire was melted in the arc zone and turned into nonuniform droplets composed of Ti-Al-V-B melt and undecomposed Ti B2 particles.With the increase of welding current,the detachment time of droplet shortened while the transfer frequency accelerated,accompanied by the improvement in coating surface quality.The spatial distribution of Ti B whiskers in coating was governed by welding current.A uniform distribution could be achieved as welding current was sufficient at the expense of elevated dilution ratio,while increasing wire feeding speed could compensate the dilution loss of Ti B whisker to some extent.The decomposition process of Ti B_(2)particles and the microstructure evolution mechanism of coating was discussed in detail.The optimum coating possessed uniform microstructure,relatively low dilution ratio,and high hardness(639.1 HV_(0.5))as compared with Ti6 Al4 V substrate(326 HV_(0.5)).Indentation morphology analysis verified the excellent performance was ascribed to the load-sharing strengthening of Ti B whiskers.This study provides a high-efficiency fabrication method for the ever-developing titanium matrix composites(TMCs)coating. 展开更多
关键词 Ti flux cored wire TiB/Ti composite coating wire-feed arc deposition Microstructure evolution Hardness
原文传递
Thermodynamic Calculation on Calcium Treatment for 26CrMo4S/2 Steel 被引量:4
4
作者 Guo-dong SUN Ya-fei SUI +2 位作者 Can-guo WANG Min GUO Mei ZHANG 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2014年第S1期61-64,共4页
Because CaSi core wire was not fed in external refining process for 26CrMo4S/2 steel making, it was found that the molar ratio of calcium versus alumina was very low and subsequently resulted in generation of much mor... Because CaSi core wire was not fed in external refining process for 26CrMo4S/2 steel making, it was found that the molar ratio of calcium versus alumina was very low and subsequently resulted in generation of much more non-metallic inclusions. Hence, it was reasonable to sugguest feeding appropriate amount of Ca core wire. Before the performance, the thermodynamic calculation had been carried out to obtain the theoretical amount of Ca wire to be fed. According to the practical data from steel plant and the thermodynamic data, it was calculated that only when 5 2/34.97 10 [%Al]T-≥×4 2/31.38 10 [%Al] [%Ca]T T-×≥≥in molten steel the Al2O3 inclusions could be properly modified. 展开更多
关键词 wire-feeding Ca Al2O3 inclusions modification thermodynamic calculation