An intergeneric artificial hybridization was conducted between Cunninghamia R. Br. and Cryptomeria D.Don The results are as follows:1. A considerable number of hybrid seeds shed from 76 pollinated cones were ...An intergeneric artificial hybridization was conducted between Cunninghamia R. Br. and Cryptomeria D.Don The results are as follows:1. A considerable number of hybrid seeds shed from 76 pollinated cones were empty and a total of 628 looks plump. Soft X ray radiographs showed that, still and all, a majority of the “plump" seeds were embryoless (597, 95.6%) whereas some were partially developed (17,2.7%) and only a few were really full (14, 2.2%). 2. Germination test showed that all of the radiographed hybrid seeds with fully developed embryos were germinable whereas those with partially developed embryos were ungerminable. 3. Physiologically, the growth rate of hypocotyl, the date for shedding of seed coat and spreading of cotyledons, the elongation of epicotyl, and the branching of shoot of the 11 month old seedlings showed a tendency to fall behind those of the female parent; morphologically, the 11 month old hybrid seedlings with linear leaves appeared rather short, slender and weak, whereas the seedlings of the female parents with linear_lanceolate leaves appeared rather tall, stout and strong. 4. It is considered that the hybrid may be true and the crossability reveals a close phylogenetic affinity of Cunninghamia with Cryptomeria.展开更多
Interfacial bonding in as deposited and annealed Co/C soft X ray multilayer structures is investigated by X ray photo electron spectroscopy (XPS).It is found that there is interdiffusion between cobalt and carbon ...Interfacial bonding in as deposited and annealed Co/C soft X ray multilayer structures is investigated by X ray photo electron spectroscopy (XPS).It is found that there is interdiffusion between cobalt and carbon in the as deposited Co/C multilayers,and this is confirmed by structure characterization using low angle X ray diffraction (LAXD).The calculation of the chemical shifts in Co C system based on Miedemas macroscopic atom model suggests that it is impossible to detect the chemical shift experimentally in the Co C compound,which is consistent with the XPS results.The presence of metallic carbide bonding is evidenced through the nature of the carbon bonding in survey taken at Co C and C Co interfaces of annealed samples.Our results also indicate that XPS is a direct method to probe the chemical bonding at the interfaces.展开更多
The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and...The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and ms.This beamline has been specifically designed to facilitate the investigation of a wide range of rapid phenomena,such as the deformation and failure of materials subjected to intense dynamic loads.In addition,it enables the study of high-pressure and high-speed fuel spray processes in automotive engines.The light source of this beamline is a cryogenic permanent magnet undulator(CPMU)that is cooled by liquid nitrogen.This CPMU can generate X-ray photons within an energy range of 8.7-30 keV.The beamline offers two modes of operation:monochromatic beam mode with a liquid nitrogen-cooled double-crystal monochromator(DCM)and pink beam mode with the first crystal of the DCM out of the beam path.Four X-ray imaging methods were implemented in BL16U2:single-pulse ultrafast X-ray imaging,microsecond-resolved X-ray dynamic imaging,millisecond-resolved X-ray dynamic micro-CT,and high-resolution quantitative micro-CT.Furthermore,BL16U2 is equipped with various in situ impact loading systems,such as a split Hopkinson bar system,light gas gun,and fuel spray chamber.Following the completion of the final commissioning in 2021 and subsequent trial operations in 2022,the beamline has been officially available to users from 2023.展开更多
Background and Aims While chest X-ray (CXR) has been a conventional tool in intensive care units (ICUs) to identify lung pathologies, computed tomography (CT) scan remains the gold standard. Use of lung ultrasound (LU...Background and Aims While chest X-ray (CXR) has been a conventional tool in intensive care units (ICUs) to identify lung pathologies, computed tomography (CT) scan remains the gold standard. Use of lung ultrasound (LUS) in resource-rich ICUs is still under investigation. The present study compares the utility of LUS to that of CXR in identifying pulmonary edema and pleural effusion in ICU patients. In addition, consolidation and pneumothorax were analyzed as secondary outcome measures. Material and Methods This is a prospective, single centric, observational study. Patients admitted in ICU were examined for lung pathologies, using LUS by a trained intensivist;and CXR done within 4 hours of each other. The final diagnosis was ascertained by an independent senior radiologist, based on the complete medical chart including clinical findings and the results of thoracic CT, if available. The results were compared and analyzed. Results Sensitivity, specificity and diagnostic accuracy of LUS was 95%, 94.4%, 94.67% for pleural effusion;and 98.33%, 97.78%, 98.00% for pulmonary edema respectively. Corresponding values with CXR were 48.33%, 76.67%, 65.33% for pleural effusion;and 36.67%, 82.22% and 64.00% for pulmonary edema respectively. Sensitivity, specificity and diagnostic accuracy of LUS was 91.30%, 96.85%, 96.00% for consolidation;and 100.00%, 79.02%, 80.00% for pneumothorax respectively. Corresponding values with CXR were 60.87%, 81.10%, 78.00% for consolidation;and 71.3%, 97.20%, 96.00% for pneumothorax respectively. Conclusion LUS has better diagnostic accuracy in diagnosis of pleural effusion and pulmonary edema when compared with CXR and is thus recommended as an effective alternative for diagnosis of these conditions in acute care settings. Our study recommends that a thoracic CT scan can be avoided in most of such cases.展开更多
A new method of calculating finely the soft X ray spectra of hydrogenlike highly ionized states is presented. It is based on the relation of the ionicity and the ionization energies of hydrogenlike atoms and the new...A new method of calculating finely the soft X ray spectra of hydrogenlike highly ionized states is presented. It is based on the relation of the ionicity and the ionization energies of hydrogenlike atoms and the new model of potential function of hydrogenlike atoms. The relativistic revision and the spin orbit couping of excitation energy levels are taken into account. The calculated results are in good agreement with the experiments.展开更多
NdCl 3 FeCl 3 graphite intercalation compounds were synthesized by molten salt exchange method. The state of the intercalates and the relative contents of Nd, Fe, Cl, C in the product were determined by X ray ph...NdCl 3 FeCl 3 graphite intercalation compounds were synthesized by molten salt exchange method. The state of the intercalates and the relative contents of Nd, Fe, Cl, C in the product were determined by X ray photoelectron spectroscopy(XPS). From the XPS data, it is concluded that the binding energy of Fe2p electrons is about 711 20~710 3 eV, the binding energy of Nd3d electrons is about 983 08~983 20 eV, and Fe in the product has two valence states (Fe 3+ and Fe 2+ ).展开更多
The compound CeNi 5Sn was studied by means of X ray powder diffraction technique and refined by Rietveld method. It has a hexagonal structure with space group P 6 3/ mmc (No.194), Z =4, the lattice constant...The compound CeNi 5Sn was studied by means of X ray powder diffraction technique and refined by Rietveld method. It has a hexagonal structure with space group P 6 3/ mmc (No.194), Z =4, the lattice constants a =0 48912(3) nm, c =1 973(2) nm and D x=8 974 g·cm -3 . The Rietveld structural refinement was performed, leading to R p=0 138 and R wp =0 185. The figure of merit F N for the XRD data is F 30 =82 1(0 0068, 54). The X ray powder diffraction data are presented.展开更多
The compound PrNiSn was studied by X ray powder diffraction technique. The crystal structure and the X ray diffraction data for this compound at room temperature were reported. The compound PrNiSn is orthorhombic wi...The compound PrNiSn was studied by X ray powder diffraction technique. The crystal structure and the X ray diffraction data for this compound at room temperature were reported. The compound PrNiSn is orthorhombic with lattice parameters a =0.74569(3) nm, b =0.76851(5) nm, c =0.45676(8) nm, V =0.26176 nm 3, Z =4 and D x=8.076 g·cm -3 , space group Pna2 1(33). The figure of merit F N for the compound is F 30 =54 (0.0093, 60).展开更多
The compound NdFe 0.6 Sb 2 was studied by means of X ray powder diffraction. The X ray powder diffraction data and structural parameters demonstrated that this compound is of the tetragonal structure with space...The compound NdFe 0.6 Sb 2 was studied by means of X ray powder diffraction. The X ray powder diffraction data and structural parameters demonstrated that this compound is of the tetragonal structure with space group P4/nmm, Z =2 and D x=7.615 g·cm -3 . The lattice parameters are a =0.43499 (1) nm and c =0.97083 (4) nm. Refinement was performed with 42 reflections.展开更多
OBJECTIVE: Bone mineral density (BMD) was measured in normal Chinese women with single X-ray absorptiometry (SXA) and dual energy X-ray absorptiometry (DEXA). These two methods were compared to evaluate the sensitivit...OBJECTIVE: Bone mineral density (BMD) was measured in normal Chinese women with single X-ray absorptiometry (SXA) and dual energy X-ray absorptiometry (DEXA). These two methods were compared to evaluate the sensitivity in reflecting bone loss. METHODS: Measurements were performed in 300 women aged 20 to approximately 79 (5 for each age). The 8mm distal, 1/4 distal, ultra distal site of the nondominant forearm were measured with SXA; the AP spine (L2-4), right femoral neck (Neck), Ward's triangle (Ward) and trochantor (Troch) were measured with DEXA. Ten women had 5 repeated measurements to evaluate the reproducibility of the equipments. RESULTS: The BMD peak for Neck and Ward was found between age 20 to approximately 29, for ultra distal and L2-4 at age 30 to approximately 39, for 8mm distal, 1/4 distal and Troch at age 40 to approximately 49. After reaching the peak values, BMD at all sites decreased with increasing age. The highest rate of yearly loss of BMD was at 8mm distal. Results of measurement showed significant correlation between SXA and DEXA. Comparing with premenopausal women, the bone loss rate in postmenopausal women was faster and highest up to 11 to approximately 15 years and the highest rate was at the Ward. CONCLUSION: The present study gives the normal values of BMD at seven sites for normal Chinese women. The ages of BMD peak were different at seven sites. The yearly loss of BMD was highest at 8mm distal, it seemed to be the sensitive region for bone loss with age. The postmenopausal women had highly significantly loss bone mass than the premenopausal women. Comparing with premenopause, postmenopause BMD for Ward's triangle with DEXA seemed to be most sensitive to the effect of menopause.展开更多
Decomposition processes of the quenched Zn-Al alloys were studied by differential scanning calorimetry (DSC), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the stabilities o...Decomposition processes of the quenched Zn-Al alloys were studied by differential scanning calorimetry (DSC), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the stabilities of supersaturated solid solution (SSS) of Zn-Al alloy and α' phase formed by quenching would reduce with the increase of Zn content and the precipitation of η-Zn phases even when aging at ambient temperature, so that the exothermic precipitation peak in DSC curve would disappear. The activation energy of the η-Zn precipitation and the reaction enthalpy were calculated and measured. The kinetics of α' decomposition or η-Zn formation was determined by XRD. The microstructure change during aging was observed by TEM.展开更多
X-ray powder diffraction data and crystal structure of NiSbY compound were studied by X-ray powderdiffraction. The compound belongs to the space group F43 m with MgAgAs structure type, and the parameters Z=4, a=0.6307...X-ray powder diffraction data and crystal structure of NiSbY compound were studied by X-ray powderdiffraction. The compound belongs to the space group F43 m with MgAgAs structure type, and the parameters Z=4, a=0.63075(2) nm.展开更多
Grazing incidence optics (GIO) is the most important compound in an x-ray detection system; it is used to concentrate the x-ray photons from outer space. A nested planar GIO for x-ray concentration is designed and d...Grazing incidence optics (GIO) is the most important compound in an x-ray detection system; it is used to concentrate the x-ray photons from outer space. A nested planar GIO for x-ray concentration is designed and developed by authors in this paper; planar segments are used as the reflection mirror instead of curved segments because of the simple process and low cost. After the complex assembling process with a special metal supporter, a final circle light spot of φ 12 mm was obtained in the visible light testing experiment of GIO; the effective area of 1710.51 mm^2@ 1 keV and 530 mm^2@8 keV is obtained in the x-ray testing experiment with the GIO-SDD combination, which is supposed to be a concentrating detector in xray detection systems.展开更多
To evaluate the residual stress in TiAl based alloys by X ray diffraction, X ray elastic constants (REC) of a γ TiAl alloy were determined. From these results, the stress state of a given phase in a duplex TiAl based...To evaluate the residual stress in TiAl based alloys by X ray diffraction, X ray elastic constants (REC) of a γ TiAl alloy were determined. From these results, the stress state of a given phase in a duplex TiAl based alloy under a uniaxial tensile loading has been characterized by X ray diffraction. The results show that the X ray elastic constants and the microscopic stresses of the given phase are different from the apparent elastic constants and the macroscopic stresses of the alloy. The reason of the different distribution of the alloy was also discussed. [展开更多
A primary study on Processing in X - ray inspection of spot weld for aluminum alloy spot welding,in- cluding for background simulation,acquisition of ideal binary image, and extraction and identifi- cation of defec...A primary study on Processing in X - ray inspection of spot weld for aluminum alloy spot welding,in- cluding for background simulation,acquisition of ideal binary image, and extraction and identifi- cation of defect features was presented.展开更多
文摘An intergeneric artificial hybridization was conducted between Cunninghamia R. Br. and Cryptomeria D.Don The results are as follows:1. A considerable number of hybrid seeds shed from 76 pollinated cones were empty and a total of 628 looks plump. Soft X ray radiographs showed that, still and all, a majority of the “plump" seeds were embryoless (597, 95.6%) whereas some were partially developed (17,2.7%) and only a few were really full (14, 2.2%). 2. Germination test showed that all of the radiographed hybrid seeds with fully developed embryos were germinable whereas those with partially developed embryos were ungerminable. 3. Physiologically, the growth rate of hypocotyl, the date for shedding of seed coat and spreading of cotyledons, the elongation of epicotyl, and the branching of shoot of the 11 month old seedlings showed a tendency to fall behind those of the female parent; morphologically, the 11 month old hybrid seedlings with linear leaves appeared rather short, slender and weak, whereas the seedlings of the female parents with linear_lanceolate leaves appeared rather tall, stout and strong. 4. It is considered that the hybrid may be true and the crossability reveals a close phylogenetic affinity of Cunninghamia with Cryptomeria.
文摘Interfacial bonding in as deposited and annealed Co/C soft X ray multilayer structures is investigated by X ray photo electron spectroscopy (XPS).It is found that there is interdiffusion between cobalt and carbon in the as deposited Co/C multilayers,and this is confirmed by structure characterization using low angle X ray diffraction (LAXD).The calculation of the chemical shifts in Co C system based on Miedemas macroscopic atom model suggests that it is impossible to detect the chemical shift experimentally in the Co C compound,which is consistent with the XPS results.The presence of metallic carbide bonding is evidenced through the nature of the carbon bonding in survey taken at Co C and C Co interfaces of annealed samples.Our results also indicate that XPS is a direct method to probe the chemical bonding at the interfaces.
基金supported by the CAS Project for Young Scientists in Basic Research(YSBR-096)the National Major Scientific Instruments and Equipment Development Project of China(No.11627901)+1 种基金the National Key Research and Development Program of China(Nos.2021YFF0701202,2021YFA1600703)the National Natural Science Foundation of China(Nos.U1932205,12275343).
文摘The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and ms.This beamline has been specifically designed to facilitate the investigation of a wide range of rapid phenomena,such as the deformation and failure of materials subjected to intense dynamic loads.In addition,it enables the study of high-pressure and high-speed fuel spray processes in automotive engines.The light source of this beamline is a cryogenic permanent magnet undulator(CPMU)that is cooled by liquid nitrogen.This CPMU can generate X-ray photons within an energy range of 8.7-30 keV.The beamline offers two modes of operation:monochromatic beam mode with a liquid nitrogen-cooled double-crystal monochromator(DCM)and pink beam mode with the first crystal of the DCM out of the beam path.Four X-ray imaging methods were implemented in BL16U2:single-pulse ultrafast X-ray imaging,microsecond-resolved X-ray dynamic imaging,millisecond-resolved X-ray dynamic micro-CT,and high-resolution quantitative micro-CT.Furthermore,BL16U2 is equipped with various in situ impact loading systems,such as a split Hopkinson bar system,light gas gun,and fuel spray chamber.Following the completion of the final commissioning in 2021 and subsequent trial operations in 2022,the beamline has been officially available to users from 2023.
文摘Background and Aims While chest X-ray (CXR) has been a conventional tool in intensive care units (ICUs) to identify lung pathologies, computed tomography (CT) scan remains the gold standard. Use of lung ultrasound (LUS) in resource-rich ICUs is still under investigation. The present study compares the utility of LUS to that of CXR in identifying pulmonary edema and pleural effusion in ICU patients. In addition, consolidation and pneumothorax were analyzed as secondary outcome measures. Material and Methods This is a prospective, single centric, observational study. Patients admitted in ICU were examined for lung pathologies, using LUS by a trained intensivist;and CXR done within 4 hours of each other. The final diagnosis was ascertained by an independent senior radiologist, based on the complete medical chart including clinical findings and the results of thoracic CT, if available. The results were compared and analyzed. Results Sensitivity, specificity and diagnostic accuracy of LUS was 95%, 94.4%, 94.67% for pleural effusion;and 98.33%, 97.78%, 98.00% for pulmonary edema respectively. Corresponding values with CXR were 48.33%, 76.67%, 65.33% for pleural effusion;and 36.67%, 82.22% and 64.00% for pulmonary edema respectively. Sensitivity, specificity and diagnostic accuracy of LUS was 91.30%, 96.85%, 96.00% for consolidation;and 100.00%, 79.02%, 80.00% for pneumothorax respectively. Corresponding values with CXR were 60.87%, 81.10%, 78.00% for consolidation;and 71.3%, 97.20%, 96.00% for pneumothorax respectively. Conclusion LUS has better diagnostic accuracy in diagnosis of pleural effusion and pulmonary edema when compared with CXR and is thus recommended as an effective alternative for diagnosis of these conditions in acute care settings. Our study recommends that a thoracic CT scan can be avoided in most of such cases.
文摘A new method of calculating finely the soft X ray spectra of hydrogenlike highly ionized states is presented. It is based on the relation of the ionicity and the ionization energies of hydrogenlike atoms and the new model of potential function of hydrogenlike atoms. The relativistic revision and the spin orbit couping of excitation energy levels are taken into account. The calculated results are in good agreement with the experiments.
文摘NdCl 3 FeCl 3 graphite intercalation compounds were synthesized by molten salt exchange method. The state of the intercalates and the relative contents of Nd, Fe, Cl, C in the product were determined by X ray photoelectron spectroscopy(XPS). From the XPS data, it is concluded that the binding energy of Fe2p electrons is about 711 20~710 3 eV, the binding energy of Nd3d electrons is about 983 08~983 20 eV, and Fe in the product has two valence states (Fe 3+ and Fe 2+ ).
文摘The compound CeNi 5Sn was studied by means of X ray powder diffraction technique and refined by Rietveld method. It has a hexagonal structure with space group P 6 3/ mmc (No.194), Z =4, the lattice constants a =0 48912(3) nm, c =1 973(2) nm and D x=8 974 g·cm -3 . The Rietveld structural refinement was performed, leading to R p=0 138 and R wp =0 185. The figure of merit F N for the XRD data is F 30 =82 1(0 0068, 54). The X ray powder diffraction data are presented.
文摘The compound PrNiSn was studied by X ray powder diffraction technique. The crystal structure and the X ray diffraction data for this compound at room temperature were reported. The compound PrNiSn is orthorhombic with lattice parameters a =0.74569(3) nm, b =0.76851(5) nm, c =0.45676(8) nm, V =0.26176 nm 3, Z =4 and D x=8.076 g·cm -3 , space group Pna2 1(33). The figure of merit F N for the compound is F 30 =54 (0.0093, 60).
文摘The compound NdFe 0.6 Sb 2 was studied by means of X ray powder diffraction. The X ray powder diffraction data and structural parameters demonstrated that this compound is of the tetragonal structure with space group P4/nmm, Z =2 and D x=7.615 g·cm -3 . The lattice parameters are a =0.43499 (1) nm and c =0.97083 (4) nm. Refinement was performed with 42 reflections.
文摘OBJECTIVE: Bone mineral density (BMD) was measured in normal Chinese women with single X-ray absorptiometry (SXA) and dual energy X-ray absorptiometry (DEXA). These two methods were compared to evaluate the sensitivity in reflecting bone loss. METHODS: Measurements were performed in 300 women aged 20 to approximately 79 (5 for each age). The 8mm distal, 1/4 distal, ultra distal site of the nondominant forearm were measured with SXA; the AP spine (L2-4), right femoral neck (Neck), Ward's triangle (Ward) and trochantor (Troch) were measured with DEXA. Ten women had 5 repeated measurements to evaluate the reproducibility of the equipments. RESULTS: The BMD peak for Neck and Ward was found between age 20 to approximately 29, for ultra distal and L2-4 at age 30 to approximately 39, for 8mm distal, 1/4 distal and Troch at age 40 to approximately 49. After reaching the peak values, BMD at all sites decreased with increasing age. The highest rate of yearly loss of BMD was at 8mm distal. Results of measurement showed significant correlation between SXA and DEXA. Comparing with premenopausal women, the bone loss rate in postmenopausal women was faster and highest up to 11 to approximately 15 years and the highest rate was at the Ward. CONCLUSION: The present study gives the normal values of BMD at seven sites for normal Chinese women. The ages of BMD peak were different at seven sites. The yearly loss of BMD was highest at 8mm distal, it seemed to be the sensitive region for bone loss with age. The postmenopausal women had highly significantly loss bone mass than the premenopausal women. Comparing with premenopause, postmenopause BMD for Ward's triangle with DEXA seemed to be most sensitive to the effect of menopause.
文摘Decomposition processes of the quenched Zn-Al alloys were studied by differential scanning calorimetry (DSC), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the stabilities of supersaturated solid solution (SSS) of Zn-Al alloy and α' phase formed by quenching would reduce with the increase of Zn content and the precipitation of η-Zn phases even when aging at ambient temperature, so that the exothermic precipitation peak in DSC curve would disappear. The activation energy of the η-Zn precipitation and the reaction enthalpy were calculated and measured. The kinetics of α' decomposition or η-Zn formation was determined by XRD. The microstructure change during aging was observed by TEM.
文摘X-ray powder diffraction data and crystal structure of NiSbY compound were studied by X-ray powderdiffraction. The compound belongs to the space group F43 m with MgAgAs structure type, and the parameters Z=4, a=0.63075(2) nm.
基金supported by the National Natural Science Foundation of China(Grant No.61471357)the State Key Laboratory of Geo-Information Engineering Foundation(Grant No.SKLGIE2014-M-2-1)
文摘Grazing incidence optics (GIO) is the most important compound in an x-ray detection system; it is used to concentrate the x-ray photons from outer space. A nested planar GIO for x-ray concentration is designed and developed by authors in this paper; planar segments are used as the reflection mirror instead of curved segments because of the simple process and low cost. After the complex assembling process with a special metal supporter, a final circle light spot of φ 12 mm was obtained in the visible light testing experiment of GIO; the effective area of 1710.51 mm^2@ 1 keV and 530 mm^2@8 keV is obtained in the x-ray testing experiment with the GIO-SDD combination, which is supposed to be a concentrating detector in xray detection systems.
文摘To evaluate the residual stress in TiAl based alloys by X ray diffraction, X ray elastic constants (REC) of a γ TiAl alloy were determined. From these results, the stress state of a given phase in a duplex TiAl based alloy under a uniaxial tensile loading has been characterized by X ray diffraction. The results show that the X ray elastic constants and the microscopic stresses of the given phase are different from the apparent elastic constants and the macroscopic stresses of the alloy. The reason of the different distribution of the alloy was also discussed. [
文摘A primary study on Processing in X - ray inspection of spot weld for aluminum alloy spot welding,in- cluding for background simulation,acquisition of ideal binary image, and extraction and identifi- cation of defect features was presented.