Background and Aims While chest X-ray (CXR) has been a conventional tool in intensive care units (ICUs) to identify lung pathologies, computed tomography (CT) scan remains the gold standard. Use of lung ultrasound (LU...Background and Aims While chest X-ray (CXR) has been a conventional tool in intensive care units (ICUs) to identify lung pathologies, computed tomography (CT) scan remains the gold standard. Use of lung ultrasound (LUS) in resource-rich ICUs is still under investigation. The present study compares the utility of LUS to that of CXR in identifying pulmonary edema and pleural effusion in ICU patients. In addition, consolidation and pneumothorax were analyzed as secondary outcome measures. Material and Methods This is a prospective, single centric, observational study. Patients admitted in ICU were examined for lung pathologies, using LUS by a trained intensivist;and CXR done within 4 hours of each other. The final diagnosis was ascertained by an independent senior radiologist, based on the complete medical chart including clinical findings and the results of thoracic CT, if available. The results were compared and analyzed. Results Sensitivity, specificity and diagnostic accuracy of LUS was 95%, 94.4%, 94.67% for pleural effusion;and 98.33%, 97.78%, 98.00% for pulmonary edema respectively. Corresponding values with CXR were 48.33%, 76.67%, 65.33% for pleural effusion;and 36.67%, 82.22% and 64.00% for pulmonary edema respectively. Sensitivity, specificity and diagnostic accuracy of LUS was 91.30%, 96.85%, 96.00% for consolidation;and 100.00%, 79.02%, 80.00% for pneumothorax respectively. Corresponding values with CXR were 60.87%, 81.10%, 78.00% for consolidation;and 71.3%, 97.20%, 96.00% for pneumothorax respectively. Conclusion LUS has better diagnostic accuracy in diagnosis of pleural effusion and pulmonary edema when compared with CXR and is thus recommended as an effective alternative for diagnosis of these conditions in acute care settings. Our study recommends that a thoracic CT scan can be avoided in most of such cases.展开更多
X-ray powder diffraction data and crystal structure of NiSbY compound were studied by X-ray powderdiffraction. The compound belongs to the space group F43 m with MgAgAs structure type, and the parameters Z=4, a=0.6307...X-ray powder diffraction data and crystal structure of NiSbY compound were studied by X-ray powderdiffraction. The compound belongs to the space group F43 m with MgAgAs structure type, and the parameters Z=4, a=0.63075(2) nm.展开更多
Industrial grade multi-walled carbon nanotubes(IG-MWCNTs) are a low-cost substitute for commercially purified multi-walled carbon nanotubes(P-MWCNTs). In this work, IG-MWCNTs were functionalized with tetraethylenepent...Industrial grade multi-walled carbon nanotubes(IG-MWCNTs) are a low-cost substitute for commercially purified multi-walled carbon nanotubes(P-MWCNTs). In this work, IG-MWCNTs were functionalized with tetraethylenepentamine(TEPA) for CO2capture. The TEPA impregnated IG-MWCNTs were characterized with various experimental methods including N2adsorption/desorption isotherms, elemental analysis, X-ray diffraction, Fourier transform infrared spectroscopy and thermogravimetric analysis. Both the adsorption isotherms of IGMWCNTs-n and the isosteric heats of different adsorption capacities were obtained from experiments. TEPA impregnated IG-MWCNTs were also shown to have high CO2adsorption capacity comparable to that of TEPA impregnated P-MWCNTs. The adsorption capacity of IG-MWCNTs based adsorbents was in the range of 2.145 to 3.088 mmol/g, depending on adsorption temperatures. Having the advantages of low-cost and high adsorption capacity, TEPA impregnated IG-MWCNTs seem to be a promising adsorbent for CO2capture from flue gas.展开更多
The residual stress in a 20%SiC w/6061Al composite as extruded was investigated by using X ray stress measurement method. It was found that, high residual stress existed in the composite and residual stress distributi...The residual stress in a 20%SiC w/6061Al composite as extruded was investigated by using X ray stress measurement method. It was found that, high residual stress existed in the composite and residual stress distribution in each direction are not uniform. Relaxation process of residual stress in the composite was dynamically measured during annealing at high temperature. It is verified that the relaxation of residual stress obeys the power law at high temperature. With the creep mechanism, the relaxation behavior of residual stresses at high temperature was analyzed. The results show that, the stress exponent and activation energy for stress relaxation of the composite are obviously higher than those of the matrix alloy.展开更多
Decomposition processes of the quenched Zn-Al alloys were studied by differential scanning calorimetry (DSC), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the stabilities o...Decomposition processes of the quenched Zn-Al alloys were studied by differential scanning calorimetry (DSC), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the stabilities of supersaturated solid solution (SSS) of Zn-Al alloy and α' phase formed by quenching would reduce with the increase of Zn content and the precipitation of η-Zn phases even when aging at ambient temperature, so that the exothermic precipitation peak in DSC curve would disappear. The activation energy of the η-Zn precipitation and the reaction enthalpy were calculated and measured. The kinetics of α' decomposition or η-Zn formation was determined by XRD. The microstructure change during aging was observed by TEM.展开更多
The structure of bcc-Fe80Cu20 solid solution produced by mechanical alloying of the elemental bcc-Fe and fcc-Cu powders has been studied using X-ray diffraction and the extended X-ray absorption fine structure (EXAFS)...The structure of bcc-Fe80Cu20 solid solution produced by mechanical alloying of the elemental bcc-Fe and fcc-Cu powders has been studied using X-ray diffraction and the extended X-ray absorption fine structure (EXAFS) techniques. The disappearance of elemental Fe and Cu X-ray diffraction (XRD) peaks and the presence of bcc structural XRD peaks illustrate the formation of a nanocrystalline single-phase bcc-Fe80Cu20 solid solution. From the EXAFS result, the clear observation of Cu atoms taking on bcc coordination in the solid solution and Fe atoms remaining bcc structure further verifies the reality of atomic alloying between Fe and Cu atoms and the lattice change of Cu from fcc to bcc. However, the supersaturated bcc solid solution is not chemically uniform, i.e., some regions are rich in Fe atoms and other regions rich in Cu atoms.展开更多
NdCl 3 FeCl 3 graphite intercalation compounds were synthesized by molten salt exchange method. The state of the intercalates and the relative contents of Nd, Fe, Cl, C in the product were determined by X ray ph...NdCl 3 FeCl 3 graphite intercalation compounds were synthesized by molten salt exchange method. The state of the intercalates and the relative contents of Nd, Fe, Cl, C in the product were determined by X ray photoelectron spectroscopy(XPS). From the XPS data, it is concluded that the binding energy of Fe2p electrons is about 711 20~710 3 eV, the binding energy of Nd3d electrons is about 983 08~983 20 eV, and Fe in the product has two valence states (Fe 3+ and Fe 2+ ).展开更多
The formation of ( t BuCp) 2ErOEt was discussed. Its single crystal structure was determined by X ray diffraction. The crystal is monoclinic, P 2(1)/ c space group, a =1.0191(2), b =1.6203(5), c ...The formation of ( t BuCp) 2ErOEt was discussed. Its single crystal structure was determined by X ray diffraction. The crystal is monoclinic, P 2(1)/ c space group, a =1.0191(2), b =1.6203(5), c =1.2118(3) nm, β =102.960(10)°, V =1.9500 (nm 3), Z =2, D c=1.566 mg·m -3 , R =0.0450, R w=0.1363. The complex is monomeric and solvent free in the solid state. The erbium ion is coordinated by two tert butyl cyclopentadienyl rings and one oxygen atom of ethoxy group to form a seven coordinated complex.展开更多
Grazing incidence optics (GIO) is the most important compound in an x-ray detection system; it is used to concentrate the x-ray photons from outer space. A nested planar GIO for x-ray concentration is designed and d...Grazing incidence optics (GIO) is the most important compound in an x-ray detection system; it is used to concentrate the x-ray photons from outer space. A nested planar GIO for x-ray concentration is designed and developed by authors in this paper; planar segments are used as the reflection mirror instead of curved segments because of the simple process and low cost. After the complex assembling process with a special metal supporter, a final circle light spot of φ 12 mm was obtained in the visible light testing experiment of GIO; the effective area of 1710.51 mm^2@ 1 keV and 530 mm^2@8 keV is obtained in the x-ray testing experiment with the GIO-SDD combination, which is supposed to be a concentrating detector in xray detection systems.展开更多
文摘Background and Aims While chest X-ray (CXR) has been a conventional tool in intensive care units (ICUs) to identify lung pathologies, computed tomography (CT) scan remains the gold standard. Use of lung ultrasound (LUS) in resource-rich ICUs is still under investigation. The present study compares the utility of LUS to that of CXR in identifying pulmonary edema and pleural effusion in ICU patients. In addition, consolidation and pneumothorax were analyzed as secondary outcome measures. Material and Methods This is a prospective, single centric, observational study. Patients admitted in ICU were examined for lung pathologies, using LUS by a trained intensivist;and CXR done within 4 hours of each other. The final diagnosis was ascertained by an independent senior radiologist, based on the complete medical chart including clinical findings and the results of thoracic CT, if available. The results were compared and analyzed. Results Sensitivity, specificity and diagnostic accuracy of LUS was 95%, 94.4%, 94.67% for pleural effusion;and 98.33%, 97.78%, 98.00% for pulmonary edema respectively. Corresponding values with CXR were 48.33%, 76.67%, 65.33% for pleural effusion;and 36.67%, 82.22% and 64.00% for pulmonary edema respectively. Sensitivity, specificity and diagnostic accuracy of LUS was 91.30%, 96.85%, 96.00% for consolidation;and 100.00%, 79.02%, 80.00% for pneumothorax respectively. Corresponding values with CXR were 60.87%, 81.10%, 78.00% for consolidation;and 71.3%, 97.20%, 96.00% for pneumothorax respectively. Conclusion LUS has better diagnostic accuracy in diagnosis of pleural effusion and pulmonary edema when compared with CXR and is thus recommended as an effective alternative for diagnosis of these conditions in acute care settings. Our study recommends that a thoracic CT scan can be avoided in most of such cases.
文摘X-ray powder diffraction data and crystal structure of NiSbY compound were studied by X-ray powderdiffraction. The compound belongs to the space group F43 m with MgAgAs structure type, and the parameters Z=4, a=0.63075(2) nm.
基金supported by Zhejiang Provincial Natural Science Foundation of China(Grant No.LZ12E08002)
文摘Industrial grade multi-walled carbon nanotubes(IG-MWCNTs) are a low-cost substitute for commercially purified multi-walled carbon nanotubes(P-MWCNTs). In this work, IG-MWCNTs were functionalized with tetraethylenepentamine(TEPA) for CO2capture. The TEPA impregnated IG-MWCNTs were characterized with various experimental methods including N2adsorption/desorption isotherms, elemental analysis, X-ray diffraction, Fourier transform infrared spectroscopy and thermogravimetric analysis. Both the adsorption isotherms of IGMWCNTs-n and the isosteric heats of different adsorption capacities were obtained from experiments. TEPA impregnated IG-MWCNTs were also shown to have high CO2adsorption capacity comparable to that of TEPA impregnated P-MWCNTs. The adsorption capacity of IG-MWCNTs based adsorbents was in the range of 2.145 to 3.088 mmol/g, depending on adsorption temperatures. Having the advantages of low-cost and high adsorption capacity, TEPA impregnated IG-MWCNTs seem to be a promising adsorbent for CO2capture from flue gas.
文摘The residual stress in a 20%SiC w/6061Al composite as extruded was investigated by using X ray stress measurement method. It was found that, high residual stress existed in the composite and residual stress distribution in each direction are not uniform. Relaxation process of residual stress in the composite was dynamically measured during annealing at high temperature. It is verified that the relaxation of residual stress obeys the power law at high temperature. With the creep mechanism, the relaxation behavior of residual stresses at high temperature was analyzed. The results show that, the stress exponent and activation energy for stress relaxation of the composite are obviously higher than those of the matrix alloy.
基金supported by the National Natural Science Foundation of China(no.21206202)Scientific and Technological Research Program of Chongqing Municipal Education Commission(no.KJ1600902)+2 种基金the Demonstration project of Chongqing"121"Scientific&Technological Support Project(CSTC2014zktjccx BX0089)Project of Key generic industry technologies of Chongqing(No.cstc2016zdcy-ztzx0020-02)Program for Innovative Research Team in Chongqing University of Technology(2015TD22)
文摘Decomposition processes of the quenched Zn-Al alloys were studied by differential scanning calorimetry (DSC), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the stabilities of supersaturated solid solution (SSS) of Zn-Al alloy and α' phase formed by quenching would reduce with the increase of Zn content and the precipitation of η-Zn phases even when aging at ambient temperature, so that the exothermic precipitation peak in DSC curve would disappear. The activation energy of the η-Zn precipitation and the reaction enthalpy were calculated and measured. The kinetics of α' decomposition or η-Zn formation was determined by XRD. The microstructure change during aging was observed by TEM.
基金Natural Science Foundation of Guangdong Province (Grant No. 20010056).
文摘The structure of bcc-Fe80Cu20 solid solution produced by mechanical alloying of the elemental bcc-Fe and fcc-Cu powders has been studied using X-ray diffraction and the extended X-ray absorption fine structure (EXAFS) techniques. The disappearance of elemental Fe and Cu X-ray diffraction (XRD) peaks and the presence of bcc structural XRD peaks illustrate the formation of a nanocrystalline single-phase bcc-Fe80Cu20 solid solution. From the EXAFS result, the clear observation of Cu atoms taking on bcc coordination in the solid solution and Fe atoms remaining bcc structure further verifies the reality of atomic alloying between Fe and Cu atoms and the lattice change of Cu from fcc to bcc. However, the supersaturated bcc solid solution is not chemically uniform, i.e., some regions are rich in Fe atoms and other regions rich in Cu atoms.
文摘NdCl 3 FeCl 3 graphite intercalation compounds were synthesized by molten salt exchange method. The state of the intercalates and the relative contents of Nd, Fe, Cl, C in the product were determined by X ray photoelectron spectroscopy(XPS). From the XPS data, it is concluded that the binding energy of Fe2p electrons is about 711 20~710 3 eV, the binding energy of Nd3d electrons is about 983 08~983 20 eV, and Fe in the product has two valence states (Fe 3+ and Fe 2+ ).
基金sponsored by the National Basic Research Program of China(973 Program)under grant no.2015CB351905the National Natural Science Foundation of China(no.61504019)+3 种基金China Postdoctoral Science Foundation(no.2015M580783)Scientific Research Start-up Foundation of University of Electronic Science and Technology of China(Y02002010301082)the Technology Innovative Research Team of Sichuan Province of China(no.2015TD0005)the Fundamental Research Funds for the Central Universities of China(no.ZYGX2015J140)
文摘The formation of ( t BuCp) 2ErOEt was discussed. Its single crystal structure was determined by X ray diffraction. The crystal is monoclinic, P 2(1)/ c space group, a =1.0191(2), b =1.6203(5), c =1.2118(3) nm, β =102.960(10)°, V =1.9500 (nm 3), Z =2, D c=1.566 mg·m -3 , R =0.0450, R w=0.1363. The complex is monomeric and solvent free in the solid state. The erbium ion is coordinated by two tert butyl cyclopentadienyl rings and one oxygen atom of ethoxy group to form a seven coordinated complex.
基金supported by the National Natural Science Foundation of China(Grant No.61471357)the State Key Laboratory of Geo-Information Engineering Foundation(Grant No.SKLGIE2014-M-2-1)
文摘Grazing incidence optics (GIO) is the most important compound in an x-ray detection system; it is used to concentrate the x-ray photons from outer space. A nested planar GIO for x-ray concentration is designed and developed by authors in this paper; planar segments are used as the reflection mirror instead of curved segments because of the simple process and low cost. After the complex assembling process with a special metal supporter, a final circle light spot of φ 12 mm was obtained in the visible light testing experiment of GIO; the effective area of 1710.51 mm^2@ 1 keV and 530 mm^2@8 keV is obtained in the x-ray testing experiment with the GIO-SDD combination, which is supposed to be a concentrating detector in xray detection systems.