期刊文献+
共找到45篇文章
< 1 2 3 >
每页显示 20 50 100
X-ray backlighting of two-wire Z-pinch plasma using X-pinch 被引量:2
1
作者 赵彤 邹晓兵 +1 位作者 张然 王新新 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期382-386,共5页
Two 50-μm Mo wires in parallel used as a Z-pinch load are electrically exploded with a pulsed current rising to 275 kA in 125 ns and their explosion processes are backlighted using an X-pinch as an x-ray source. The ... Two 50-μm Mo wires in parallel used as a Z-pinch load are electrically exploded with a pulsed current rising to 275 kA in 125 ns and their explosion processes are backlighted using an X-pinch as an x-ray source. The backlighting images show clearly the processes similar to those occurring in the initial stages of a cylindrical wire-array Z-pinch, including the electric explosion of single wires characterised by the dense wire cores surrounded by a low-density coronal plasma, the expansion of the exploding wire, the sausage instability (m = 0) in the coronal plasma around each wire, the motion of the coronal plasma as well as the wire core toward the current centroid, the formation of the precursor plasma column with a twist structure something like that of higher mode instability, especially the kink instability (m = 1). 展开更多
关键词 X-PINCH Z-PINCH x-ray backlighting
下载PDF
Monte Carlo simulation for bremsstrahlung and photoneutron yields in high-energy x-ray radiography 被引量:1
2
作者 许海波 彭现科 陈朝斌 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第6期213-220,共8页
This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray ... This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray radiography. A comparison between measurements and calculations for bremsstrahlung and photoneutrons is presented. The radiographic rule and the effect of the collimator on the image are studied with the experimental model. The results provide exact parameters for the optimal design of radiographic layout and shielding systems. 展开更多
关键词 x-ray radiography BREMSSTRAHLUNG PHOTONEUTRON energy spectrum angular distribution
下载PDF
Flash X-ray radiography technique to study the high velocity impact of soft projectile on E-glass/epoxy composite material
3
作者 B.Venkata Ramudu C.Jayarami Reddy V.Madhu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2019年第2期216-226,共11页
In the present paper, the high velocity impact of 9 mm soft lead projectile on 10 mm and 30 mm thick Eglass/epoxy composites was studied using a 450 kV Flash X-ray radiography(FXR) system. The basic parameters of FXR ... In the present paper, the high velocity impact of 9 mm soft lead projectile on 10 mm and 30 mm thick Eglass/epoxy composites was studied using a 450 kV Flash X-ray radiography(FXR) system. The basic parameters of FXR imaging, such as effect of ratio of target to film(TF) and source to target(ST) distances and X-ray penetration thickness of the composite material were optimized based on clarity and the actual dimensions of the objects. The optimized parameters were used in the FXR imaging of the ballistic event of 9 mm soft projectile on E-glass/epoxy composite. The real time deformation patterns of both the projectile and composite target during the ballistic impact were captured and studied at different time intervals. The notable failure modes of the 10 mm thick target with time include fibre breakage, bulging on the back side, delamination, recovery of the bulging, reverse bulging and its recovery. However, with increase in thickness of the target to 30 mm the only failure mechanism observed is the breaking of fibres. The ballistic impact event was also numerically simulated using commercially available LS-DYNA software. The numerically simulated deformation patterns of the projectile and target at different time intervals are closely matching with the corresponding radiographic images. 展开更多
关键词 FLASH x-ray radiography E-Glass/epoxy composite BALLISTIC impact Numerical simulation
下载PDF
Low Energy Plasma Focus as an Intense X-ray Source for Radiography
4
作者 S.Hussain M.Zakaullah +1 位作者 Shujaat Ali A.Waheed 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第3期2296-2300,共5页
Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode ... Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated. 展开更多
关键词 plasma focus x-ray source radiography
下载PDF
X-Pinches as Broadband Sources of X-Rays for Radiography
5
作者 Tatiana Shelkovenko Sergey Pikuz David Hammer 《Journal of Biomedical Science and Engineering》 2015年第11期747-755,共9页
Two methods of using the X-pinch as a source of X-ray radiation for radiography of biological objects are presented. X-pinches are found to be a very flexible method for generation of radiation over a wide spectral ra... Two methods of using the X-pinch as a source of X-ray radiation for radiography of biological objects are presented. X-pinches are found to be a very flexible method for generation of radiation over a wide spectral range and provide a high spatial and temporal resolution. 展开更多
关键词 X-PINCH x-ray HOT SPOT Electron Beam Point-Projection radiography Biological Object
下载PDF
Development of a monochromatic crystal backlight imager for the recent double-cone ignition experiments
6
作者 张成龙 张翌航 +11 位作者 远晓辉 张喆 徐妙华 戴羽 董玉峰 谷昊琛 刘正东 赵旭 李玉同 李英骏 朱健强 张杰 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期40-45,共6页
We developed a monochromatic crystal backlight imaging system for the double-cone ignition(DCI) scheme, employing a spherically bent quartz crystal. This system was used to measure the spatial distribution and tempora... We developed a monochromatic crystal backlight imaging system for the double-cone ignition(DCI) scheme, employing a spherically bent quartz crystal. This system was used to measure the spatial distribution and temporal evolution of the head-on colliding plasma from the two compressing cones in the DCI experiments. The influence of laser parameters on the x-ray backlighter intensity and spatial resolution of the imaging system was investigated. The imaging system had a spatial resolution of 10 μm when employing a CCD detector. Experiments demonstrated that the system can obtain time-resolved radiographic images with high quality, enabling the precise measurement of the shape, size, and density distribution of the plasma. 展开更多
关键词 double-cone ignition(DCI) spatial resolution x-ray radiography
下载PDF
Radiography Image Classification Using Deep Convolutional Neural Networks
7
作者 Ahmad Chowdhury Haiyi Zhang 《Journal of Computer and Communications》 2024年第6期199-209,共11页
Research has shown that chest radiography images of patients with different diseases, such as pneumonia, COVID-19, SARS, pneumothorax, etc., all exhibit some form of abnormality. Several deep learning techniques can b... Research has shown that chest radiography images of patients with different diseases, such as pneumonia, COVID-19, SARS, pneumothorax, etc., all exhibit some form of abnormality. Several deep learning techniques can be used to identify each of these anomalies in the chest x-ray images. Convolutional neural networks (CNNs) have shown great success in the fields of image recognition and image classification since there are numerous large-scale annotated image datasets available. The classification of medical images, particularly radiographic images, remains one of the biggest hurdles in medical diagnosis because of the restricted availability of annotated medical images. However, such difficulty can be solved by utilizing several deep learning strategies, including data augmentation and transfer learning. The aim was to build a model that would detect abnormalities in chest x-ray images with the highest probability. To do that, different models were built with different features. While making a CNN model, one of the main tasks is to tune the model by changing the hyperparameters and layers so that the model gives out good training and testing results. In our case, three different models were built, and finally, the last one gave out the best-predicted results. From that last model, we got 98% training accuracy, 84% validation, and 81% testing accuracy. The reason behind the final model giving out the best evaluation scores is that it was a well-fitted model. There was no overfitting or underfitting issues. Our aim with this project was to make a tool using the CNN model in R language, which will help detect abnormalities in radiography images. The tool will be able to detect diseases such as Pneumonia, Covid-19, Effusions, Infiltration, Pneumothorax, and others. Because of its high accuracy, this research chose to use supervised multi-class classification techniques as well as Convolutional Neural Networks (CNNs) to classify different chest x-ray images. CNNs are extremely efficient and successful at reducing the number of parameters while maintaining the quality of the primary model. CNNs are also trained to recognize the edges of various objects in any batch of images. CNNs automatically discover the relevant aspects in labeled data and learn the distinguishing features for each class by themselves. 展开更多
关键词 CNN radiography Image Classification R Keras Chest x-ray Machine Learning
下载PDF
In situ study on columnar-equiaxed transition and anaxial columnar dendrite growth of Al-15%Cu alloy by synchrotron radiography 被引量:3
8
作者 李发国 东青 +5 位作者 张佼 戴永兵 付亚楠 谢红兰 尹付成 孙宝德 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2014年第7期2112-2116,共5页
Directional solidification of Al-15% (mass fraction) Cu alloy was investigated by in situ and real time radiography which was performed by Shanghai synchrotron radiation facility (SSRF). The imaging results reveal... Directional solidification of Al-15% (mass fraction) Cu alloy was investigated by in situ and real time radiography which was performed by Shanghai synchrotron radiation facility (SSRF). The imaging results reveal that columnar to equiaxed transition (CET) is provoked by external thermal disturbance. The detaching and floating of fragments of dendrite arms are the prelude of the transition when the solute boundary layer in front of the solid-liquid interface is thin. And the dendrite triangular tip is the fracture sensitive zone. When the conditions are suitable, new dendrites can sprout and grow up. This kind of dendrite has no obvious stem and is named anaxial columnar dendrites. 展开更多
关键词 Al-15%Cu alloy directional solidification columnar to equiaxed transition synchrotron x-ray radiography
下载PDF
Simulation study on characteristics of information extraction in multiple-image radiography
9
作者 Cui Zhang Xiao-Dong Pan +4 位作者 Jing-Jie Ding Hong-Jie Shang Zhang-Gu Chen Yong-Fan Pu Gong-Ping Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第5期87-97,共11页
Simulation experiments were performed to investigate the characteristics of information extraction in multiple-image radiography(MIR) based on geometrical optics approximation. Different Poisson noise levels were adde... Simulation experiments were performed to investigate the characteristics of information extraction in multiple-image radiography(MIR) based on geometrical optics approximation. Different Poisson noise levels were added to the simulation, and the results show that Poisson noise deteriorates the extraction results, with the degree of refraction > USAXS > absorption. The effects of Poisson noise are negligible when the detector's photon counts are about 1000 ph/pixel. A wider sampling range allows more accurate extraction results, but a narrower sampling range has a better signal-to-noise ratio for high Poisson noise levels, e.g., PN(10). The sampling interval can be suitably increased with a minor impact on the extraction results for low Poisson noise levels(PN(10000)). The extraction results are incomplete because a portion of the samplerocking curve is beyond the sampling range. This induces artifacts in the images, especially for strong refraction and USAXS signals. The artifacts are not obvious when the refraction angle and standard deviation of the USAXS are smaller than the sampling range by an order of magnitude.In general, the absorption barely affects the extraction results. However, additional Poisson noise will be generated when the sample is made of high-Z elements or has a large size due to the strong absorption. Here, the extraction results will deteriorate, and additional exposure time is required. This simulation provides important details on practical applications of MIR, with improvements in information extraction. 展开更多
关键词 x-ray imaging Phase CONTRAST ROCKING CURVE Multiple-image radiography
下载PDF
Enhanced K-Edge Radiography Using a High-Spatial-Resolution Cadmium Telluride Array Detector
10
作者 Manabu Watanabe Eiichi Sato +5 位作者 Yasuyuki Oda Hodaka Moriyama Osahiko Hagiwara Hiroshi Matsukiyo Toshiyuki Enomoto Shinya Kusachi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第3期296-307,共12页
To confirm the imaging effect of a dual-energy (DE) cadmium telluride (CdTe) array detector (XCounter, Actaeon) and to perform fundamental studies on DE computed tomography, we performed enhanced K-edge radiography us... To confirm the imaging effect of a dual-energy (DE) cadmium telluride (CdTe) array detector (XCounter, Actaeon) and to perform fundamental studies on DE computed tomography, we performed enhanced K-edge radiography using iodine (I) and gadolinium (Gd) media. DE radiography was performed using an X-ray generator with a 0.1-mm-diam-focus tube and a 0.5-mm-thick beryllium window, a 1.0-mm-thick aluminum filter for absorbing extremely low-energy photons, and the CdTe array detector with pixel dimensions of 0.1 × 0.1 mm2. Each pixel has a charge-sensitive amplifier and a dual-energy counter, and the event pulses from the amplifier are sent to the counter to determine two threshold energies. The tube current was a maximum value of 0.50 mA, and the tube voltages for I- and Gd-K-edge radiograms were 60 and 80 kV, respectively. In the I-K-edge radiography of a dog-heart phantom at an energy range of 33 - 60 keV, the muscle density increased, and fine coronary arteries were visible. Utilizing Gd-K-edge radiography of a rabbit head phantom at an energy range of 50 - 80 keV, the muscle density increased, and fine blood vessels in the nose were observed at high contrasts. Using the DE array detector, we confirmed the image-contrast variations with changes in the threshold energy. 展开更多
关键词 x-ray Photon COUNTING CdTe-Array Detector DUAL-ENERGY Energy-Dispersive radiography I-K-Edge radiography Gd-K-Edge radiography
下载PDF
A Derived Exposure Chart for Computed Radiography in a Negroid Population
11
作者 Thomas Adejoh Odira C. Ewuzie +2 位作者 Joshua K. Ogbonna Stanley O. Nwefuru Nnamdi C. Onuegbu 《Health》 CAS 2016年第10期953-958,共6页
Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiograp... Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiographer to keep exposure as low as reasonably achievable. Objective: To derive a computed radiography exposure chart for a negroid population using AGFA photostimulable phosphor plates and a GE static X-ray machine. Materials and Method: A static X-ray machine, a digitizer, and photostimulable phosphor plates were used for the X-ray examination. Chest examinations were done at a Focus-Film-Distance (FFD) of 150 - 180 cm while all other examinations were conducted at 90 - 100 cm FFD. The range of exposure factors (kVp, mA and mAs) used by radiog-raphers in the centre was noted and the 90th percentile calculated. Over a three-month period, the patients were examined with the 90th percentile of tube potential (kVp) while keeping other factors constant. The kVp was gradually decreased and halted if radiologists and radiographers uncon-nected with the work expressed misgivings about the quality of the image. A similar procedure was adopted for the tube current (mA). The threshold adopted as low as reasonably achievable was the factor preceding the point of observation by other personnel. Metrics for central tendency from the statistical packages for social sciences, version 17.0 was used to analyze the data. Results: 335 subjects of both gender aged 0 - 92 years were examined by the researchers. Adult exposure factors used by the radiographers (and those derived by the researchers) had a range of 45 - 130 kVp (62 - 94 kVp), 63 - 320 mA (100 - 250 mA) and 4.0 - 25.0 mAs (5.0 - 20.0 mAs) respectively. Pediatric chest (and researchers-derived) factors were 50 - 75 kVp (52 - 65 kVp), 50 - 250 mA (100 - 220 mA) and 3.20 - 10.0 mAs (3.2 - 6.5 mAs) respectively. Conclusion: Upper threshold of adult (and paediatric) exposure factors in computed radiography with comparable equipment and accessories should not exceed 94 kVp (65 kVp), 250 mA (220 mA) and 20.0 mAs (6.5 mAs) respectively. The derived exposure chart is also adequate to address motion unsharpness in chest examinations. 展开更多
关键词 Computed radiography EXPOSURE RADIOGRAPHER kVp Tube Current x-ray
下载PDF
Economic Evaluation of Conventional Radiography with Film and Computed Radiography: Applied at BMC
12
作者 Usama Ali Rahoma Pavan Kumar Chundi 《Advances in Computed Tomography》 2012年第3期23-29,共7页
Conventional radiography with film (CRF) has been in use for diagnostic purposes for a long time now. It has proved to be a great assert for the radiographers in assessing various abnormalities. With recent advances i... Conventional radiography with film (CRF) has been in use for diagnostic purposes for a long time now. It has proved to be a great assert for the radiographers in assessing various abnormalities. With recent advances in technology it is now possible to have digital solutions for radiography problems at a very cost effective, environment friendly and also with better image quality in certain applications when compared to CRF. Rather than using a CRF a computed radiography (CR) uses imaging plates to capture the image. The imaging plate contains photosensitive phosphors which contain the latent image. Later this plate is introduced into a reader which is then converted into a digital image. The major advantage and the cost effective element of this system is the ability to reuse the imaging plates unlike the photographic film where in only a single image can be captured and cannot be reused. The computed radiography drastically reduces the cost by eliminating the use of chemicals like film developers and fixers and also the need for a storage room. It also helps to reduce the costs that are involved in the disposal of wastes due to conventional radiography. This paper investigates whether it is cost effective to use computed radiography over film based system at Al-Batnan Medical Center (BMC), Tobruk, Libya by using Cost Benefit Analysis (CBA). Apart from the initial cost of the CR System, based on the data collected from the center, from the year 2008 to 2012 (until June 2012) a total of 581,566 images were produced with the total cost incurred using film based system being USD 4,652,528. If the same number of images were produced using a CR system the total cost incurred would have been USD 82,600. Taking into consideration the cost of a new CR system to be USD 120,000 the overall cost of producing these images is USD 202,600. It is observed that an amount of USD 4,449,928 could have been saved over the period of 5 years starting from 2008 to 2012 by using the CR system at BMC. Using Cost Benefit Analysis, the average value of the net difference between the costs and benefits for the conventional film based system is ?83.38 where as for the Computed System it is 22.06. Based on the principles of Cost Benefit Analysis it can be concluded that the system with a net positive difference is more cost beneficial than the other. With the help of the above two analysis it can be concluded that the use of computed radiography is definitely more cost effective for use at BMC, when compared to the conventional x-ray radiography. 展开更多
关键词 RADIOGRAPHIC FILM x-ray radiography COMPUTED radiography Cost BENEFIT Analysis
下载PDF
强激光加载下铝、锡微喷特性实验研究
13
作者 罗笔瀚 王洪建 冯永祯 《激光杂志》 CAS 北大核心 2024年第5期25-33,共9页
基于皮秒激光驱动的高能X射线源具有微焦点、高亮度和高分辨的优良特性,已成为研究金属材料微层裂和微喷射现象的热门诊断方法之一。锡因其熔点较低而成为微喷研究熔化影响的首选材料,铝由于熔点相对较高,不易发生冲击或卸载熔化形成液... 基于皮秒激光驱动的高能X射线源具有微焦点、高亮度和高分辨的优良特性,已成为研究金属材料微层裂和微喷射现象的热门诊断方法之一。锡因其熔点较低而成为微喷研究熔化影响的首选材料,铝由于熔点相对较高,不易发生冲击或卸载熔化形成液滴喷射,因此,铝微喷实验研究结果相对较少。基于“星光-III”激光装置的纳秒加载源和皮秒束诊断源,发展了皮秒激光驱动高能X射线背光照相技术,研究了表面含V型几何缺陷的金属锡、铝微喷特性,通过延时控制,获取了两种典型金属微喷射过程的高分辨物理图像,得到了喷射物质的形态分布、平均速度和面密度分布等重要信息。采用SPH方法对实验结果进行了数值模拟分析,揭示了实验中喷射物的形成机理以及高速喷射物质的来源。 展开更多
关键词 强激光 金属微喷 表面缺陷 X射线背光照相
下载PDF
Normative vertebral deformity measurements in a clinically relevant population using magnetic resonance imaging
14
作者 Olivia R Sorci Rashad Madi +5 位作者 Sun Min Kim Alexandra S Batzdorf Austin Alecxih Julia N Hornyak Sheenali Patel Chamith S Rajapakse 《World Journal of Radiology》 2024年第12期749-759,共11页
BACKGROUND Osteoporosis is the leading cause of vertebral fractures.Dual-energy X-ray absor-ptiometry(DXA)and radiographs are traditionally used to detect osteoporosis and vertebral fractures/deformities.Magnetic reso... BACKGROUND Osteoporosis is the leading cause of vertebral fractures.Dual-energy X-ray absor-ptiometry(DXA)and radiographs are traditionally used to detect osteoporosis and vertebral fractures/deformities.Magnetic resonance imaging(MRI)can be utilized to detect the relative severity of vertebral deformities using three-dimen-sional information not available in traditional DXA and lateral two-dimensional radiography imaging techniques.AIM To generate normative vertebral parameters in women using MRI and DXA scans,determine the correlations between MRI-calculated vertebral deformities and age,DXA T-scores,and DXA Z-scores,and compare MRI vertebral deformity values with radiography values previously published in the literature.METHODS This study is a retrospective vertebral morphometric analysis conducted at our institution.The patient sample included MR images from 1638 female patients who underwent both MR and DXA imaging between 2005 and 2014.Biconcavity,wedge,crush,anterior height(Ha)/posterior height(Hp),and middle height(Hm)/posterior height values were calculated from the MR images of the patient’s vertebrae.Associations between vertebral deformity values,patient age,and DXA T-scores were analyzed using Spearman correlation.The MRI-derived measure-ments were compared with radiograph-based calculations from population-based data compiled from multiple studies.RESULTS Age was positively correlated with lumbar Hm/Hp(P=0.04)and thoracic wedge(P=0.03)and biconcavity(P=0.001)and negatively correlated with thoracic Ha/Hp(P=0.002)and Hm/Hp(P=0.001)values.DXA T-scores correlated positively with lumbar Hm/Hp(P<0.0001)and negatively with lumbar wedge(P=0.046),biconcavity(P<0.0001),and Ha/Hp(P=0.046)values.Qualitative analysis revealed that Ha/Hp differed between MRI and radiography population-based data by no more than 0.3 and Hm/Hp by a maximum of 1.2.CONCLUSION Compared with traditional imaging techniques,MRI detects vertebral deformities with high accuracy and re-liability.It may be a sensitive,ionizing,radiation-free tool for use in clinical settings. 展开更多
关键词 Magnetic resonance imaging Dual-energy x-ray absorptiometry radiography Vertebral deformities Biconca-vity Wedge CRUSH Vertebral fractures
下载PDF
神光Ⅱ装置靶丸内爆过程X射线背光照相实验研究 被引量:4
15
作者 刘慎业 杨国洪 +8 位作者 张继彦 李军 黄翼翔 胡昕 易荣清 杜华冰 曹柱荣 张海鹰 丁永坤 《强激光与粒子束》 EI CAS CSCD 北大核心 2011年第12期3333-3337,共5页
在神光Ⅱ装置上,8路激光注入金柱腔靶产生X射线驱动位于柱腔中心的DD靶丸内爆,第9路激光辐照Pd背光靶产生的L线X射线透视内爆靶丸,用针孔成像方式获得靶丸的透视图像,高速X射线条纹相机记录靶丸透视图像,建立了间接驱动内爆靶丸背光照... 在神光Ⅱ装置上,8路激光注入金柱腔靶产生X射线驱动位于柱腔中心的DD靶丸内爆,第9路激光辐照Pd背光靶产生的L线X射线透视内爆靶丸,用针孔成像方式获得靶丸的透视图像,高速X射线条纹相机记录靶丸透视图像,建立了间接驱动内爆靶丸背光照相的实验方法,清晰地观测到了靶丸内爆的过程,对透视图像分析获得了内爆靶丸壳层运动轨迹和速度的实验数据,所获实验结果可用于间接驱动靶丸优化设计,还可用于内爆动力学数值模拟建模和计算结果的验证。 展开更多
关键词 惯性约束聚变 背光照相 内爆 X射线
下载PDF
非理想背光照相对靶壳阿贝尔密度反演的影响 被引量:2
16
作者 单连强 周维民 +10 位作者 赵宗清 韩丹 吴凤娟 谭放 刘红杰 刘东晓 伍波 余金清 钱凤 曹磊峰 谷渝秋 《强激光与粒子束》 EI CAS CSCD 北大核心 2013年第3期651-656,共6页
建立了背光照相的模拟手段,研究了记录屏像素尺寸、背光强度分布、背光光谱非单色、针孔弥散及针孔形状对惯性约束聚变中常用塑料球壳的阿贝尔密度反演的影响。结果表明:较大的记录屏像素尺寸会掩盖密度分布的细节;高斯型的背光空间分... 建立了背光照相的模拟手段,研究了记录屏像素尺寸、背光强度分布、背光光谱非单色、针孔弥散及针孔形状对惯性约束聚变中常用塑料球壳的阿贝尔密度反演的影响。结果表明:较大的记录屏像素尺寸会掩盖密度分布的细节;高斯型的背光空间分布会使密度分布低于真实值,可能导致非物理的负密度分布;采用Mo的L带谱线作为背光源也会导致反演密度偏离真实值;当壳层厚度小于针孔尺寸时,针孔弥散效应会显著降低峰值密度,利用维纳滤波法处理背光图像后密度反演的结果得到明显改善;相同针孔面积条件下,椭圆形针孔给出的峰值密度要低于圆形针孔的结果。 展开更多
关键词 背光照相 阿贝尔反演 密度分布 模拟分析
下载PDF
激光等离子体射流驱动亚毫米直径铝飞片及姿态诊断 被引量:3
17
作者 税敏 席涛 +11 位作者 闫永宏 于明海 储根柏 朱斌 何卫华 赵永强 王少义 范伟 卢峰 杨雷 辛建婷 周维民 《物理学报》 SCIE EI CAS CSCD 北大核心 2022年第9期198-204,共7页
强激光烧蚀低密度有机材料形成等离子体射流碰撞,可以对材料进行准等熵加载,比激光冲击加载应变率低,相同压强下可以获得更高的压缩度和更低的温升,在状态方程、飞片加速等方面有很强的应用前景.在星光Ⅲ置上首次开展了等离子体射流驱... 强激光烧蚀低密度有机材料形成等离子体射流碰撞,可以对材料进行准等熵加载,比激光冲击加载应变率低,相同压强下可以获得更高的压缩度和更低的温升,在状态方程、飞片加速等方面有很强的应用前景.在星光Ⅲ置上首次开展了等离子体射流驱动小尺寸铝飞片及姿态诊断联合实验.通过调控有机材料厚度和真空间隙长度,获得了厚度20μm、直径约400μm的铝飞片,飞片加速时间长达200 ns.基于ps拍瓦激光的高能X光背光照相结果显示铝飞片在飞行约400μm距离后仍然保持了很好的飞行姿态和完整性. 展开更多
关键词 激光驱动飞片 等离子体射流 准等熵加载 高能X光背光照相
下载PDF
Effect of cooling rates on the dendritic morphology transition of Mg–6Gd alloy by in situ X-ray radiography 被引量:9
18
作者 Yongbiao Wang Liming Peng +5 位作者 Yanzhou Ji Xiaoxing Cheng Cunlong Wang Yujuan Wu Yanan Fu Long-Qing Chen 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2018年第7期1142-1148,共7页
The effect of cooling rate on the transition of dendrite morphology of a Mg-6Gd (wt%) alloy was semiquantitatively analyzed under a constant temperature gradient by using synchrotron X-ray radiographic technique. Re... The effect of cooling rate on the transition of dendrite morphology of a Mg-6Gd (wt%) alloy was semiquantitatively analyzed under a constant temperature gradient by using synchrotron X-ray radiographic technique. Results show that equiaxed dendrites, including exotic 'butterfly-shaped' dendrite morphology, dominate at high cooling rate (〉1 K/s). When the cooling rate decreases in the range of 0.5-1 K/s, the equiaxed-to-columnar transition takes place, and solute segregates at the center of two long dendrite arms (LDA) of the 'butterfly-shaped' dendrite. When the cooling rate is lower than 0.3 K/s, directional solidification occurs and the columnar dendritic growth direction gradually rotates from the crystalline axis to the thermal gradient direction with an increase in cooling rate. Meanwhile, interface moves faster but the dendrite arm spacing decreases. Floating, collision and rotation of dendrites under convection were also studied in this work.2018 Published by Elsevier Ltd on behalf of The editorial office of Journal of Materials Science & Technology. 展开更多
关键词 Synchrotron x-ray radiography Mg-Gd alloy Cooling rate 6-fold equiaxed dendrite Butterfly-shaped Dendrite
原文传递
High-resolution X-ray flash radiography of Ti characteristic lines with multilayer Kirkpatrick–Baez microscope at the Shenguang-ⅡUpdate laser facility 被引量:4
19
作者 Shengzhen Yi Feng Zhang +3 位作者 Qiushi Huang Lai Wei Yuqiu Gu Zhanshan Wang 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2021年第3期61-67,共7页
High-resolution X-ray flash radiography of Ti characteristic lines with a multilayer Kirkpatrick-Baez microscope was developed on the Shenguang-Ⅱ(SG-Ⅱ)Update laser facility.The microscope uses an optimized multilaye... High-resolution X-ray flash radiography of Ti characteristic lines with a multilayer Kirkpatrick-Baez microscope was developed on the Shenguang-Ⅱ(SG-Ⅱ)Update laser facility.The microscope uses an optimized multilayer design of Co/C and W/C stacks to obtain a high reflection efficiency of the Ti characteristic lines while meeting the precise alignment requirement at the Cu Kα line.The alignment method based on dual simulated balls was proposed herein,which simultaneously realizes an accurate indication of the center field of view and the backlighter position.The optical design,multilayer coatings,and alignment method of the microscope and the experimental result of Ti flash radiography of the Au-coned CH shell target on the SG-Ⅱ Update are described. 展开更多
关键词 flash radiography Kirkpatrick-Baez microscope plasma diagnostics x-ray imaging x-ray multilayer
原文传递
Short-pulse laser-driven x-ray radiography 被引量:4
20
作者 E.Brambrink S.Baton +17 位作者 M.Koenig R.Yurchak N.Bidaut B.Albertazzi J.E.Cross G.Gregori A.Rigby E.Falize A.Pelka F.Kroll S.Pikuz Y.Sakawa N.Ozaki C.Kuranz M.Manuel C.Li P.Tzeferacos D.Lamb 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2016年第3期101-105,共5页
We have developed a new radiography setup with a short-pulse laser-driven x-ray source. Using a radiography axis perpendicular to both long- and short-pulse lasers allowed optimizing the incident angle of the short-pu... We have developed a new radiography setup with a short-pulse laser-driven x-ray source. Using a radiography axis perpendicular to both long- and short-pulse lasers allowed optimizing the incident angle of the short-pulse laser on the x-ray source target. The setup has been tested with various x-ray source target materials and different laser wavelengths.Signal to noise ratios are presented as well as achieved spatial resolutions. The high quality of our technique is illustrated on a plasma flow radiograph obtained during a laboratory astrophysics experiment on POLARs. 展开更多
关键词 laboratory astrophysics short-pulse laser x-ray radiography
原文传递
上一页 1 2 3 下一页 到第
使用帮助 返回顶部