The present study investigates the difference in interdecadal variability of the spring and summer sensible heat fluxes over Northwest China by using station observations from 1960 to 2000. It was found that the sprin...The present study investigates the difference in interdecadal variability of the spring and summer sensible heat fluxes over Northwest China by using station observations from 1960 to 2000. It was found that the spring sensible heat flux over Northwest China was greater during the period from the late 1970s to the 1990s than during the period from the 1960s to the mid-1970s. The summer sensible heat flux was smaller in the late 1980s through the 1990s than it was in the 1970s through the early 1980s. Both the spring and summer land-air temperature differences over Northwest China displayed an obvious interdecadal increase in the late 1970s. Both the spring and summer surface wind speeds experienced an obvious interdecadal weakening in the late 1970s. The change in the surface wind speed played a more important role in the interdecadal variations in sensible heat flux during the summer, whereas the change in the land-air temperature difference was more important for the interdecadal variations in sensible heat flux in the spring. This difference was related to seasonal changes in the mean land-air temperature difference and the surface wind speed. Further analysis indicated that the increase in the spring land surface temperature in Northwest China was related to an increase in surface net radiation.展开更多
The present study compares seasonal and interdecadal variations in surface sensible heat flux over Northwest China between station observations and ERA-40 and NCEP-NCAR reanalysis data for the period 1960-2000. While ...The present study compares seasonal and interdecadal variations in surface sensible heat flux over Northwest China between station observations and ERA-40 and NCEP-NCAR reanalysis data for the period 1960-2000. While the seasonal variation in sensible heat flux is found to be consistent between station observations and the two reanalysis datasets, both land-air temperatures difference and surface wind speed show remarkable systematic differences. The sensible heat flux displays obvious interdecadal variability that is season-dependent. In the ERA-40 data, the sensible heat flux in spring, fall, and winter shows interdecadal variations that are similar to observations. In the NCEP-NCAR reanalysis data, sensible heat flux variations are inconsistent with and sometimes even opposite to observations. While surface wind speeds from the NCEP-NCAR reanalysis data show interdecadal changes consistent with station observations, variations in land-air temperature difference differ greatly from the observed dataset. In terms of land-air temperature difference and surface wind speed, almost no consistency with observations can be identified in the ERA-40 data, apart from the land-air temperature difference in fall and winter. These inconsistencies pose a major obstacle to the application in climate studies of surface sensible heat flux derived from reanalysis data.展开更多
The present study documents the variability of surface sensible heat flux over Northwest China using station observations for the period 1961 2000.It is found that the afternoon and nighttime sensible heat flux variat...The present study documents the variability of surface sensible heat flux over Northwest China using station observations for the period 1961 2000.It is found that the afternoon and nighttime sensible heat flux variations are remarkably different.The variability of the instant flux in the afternoon is much larger than in the nighttime.The afternoon and nighttime flux anomalies tend to be opposite.The diurnal and seasonal dependence of sensible heat flux variations is closely related to the diurnal cycle of mean land-air temperature difference.The relationship of sensible heat flux with land-air temperature difference based on the instant value differs from that based on the daily mean.The present study indicates the importance for the models to properly simulate mean land-air temperature difference and its diurnal and seasonal variations in order to capture surface sensible heat flux variability over Northwest China and predicts its plausible impacts on climate.展开更多
Considering the continuous functioning of a power transformer under charge of high capacity of 50 MVA, predicted studies are proposed to be performed of their thermal behavior under perma nent and variable regimens of...Considering the continuous functioning of a power transformer under charge of high capacity of 50 MVA, predicted studies are proposed to be performed of their thermal behavior under perma nent and variable regimens of flow of charge, using noninvasive methods based in integral trans forms that measure and determine parameters of geometrical, analytical and physical type of the transformer. In before works, we have studied a basic geometry of a winding composed of high and low voltage sections with a uniform heat generation and heat convection boundary conditions. The heat conduction equation representing the phenomena of heat generation in a cylindrical structure was solved by using an integral transform. In this sense, this new study considers the basic geometry composed of a three cylindrical windings (high and low voltage turns) and a rec tangular core. Thus it is proposed to solve magnetic flow equations using integral transforms (Han kel transforms and Bessel integrals) in order to obtain the heat source distribution in the core due to the magnetization currents which are developed in function of the magnetic field flow equations. Based on this, it is proposed as a second step to use this heat source distribution to obtain the corresponding temperature distribution in the core by solving the cylindrical heat conduction equation for the core (cylindrical). Bearing this in mind, it is proposed finally to solve the 3D cylindrical heat conduction equation for the one winding using the calculated heat convection coefficients, the conductivity of the winding, behavior of the mineral oil and the non uniform winding heat generation predicted in recent researches. This equation will be solved by using integral methods (Radon, Hankel and Fourier transforms). This methodology will be useful to establish a new design of a power transformer based on the values of their integrals and the results that throw the inverse methods for this case. Finally if possible we will use the programs of Fluent and/or Phoenics for the validation of functional proposed models of prediction and prevention of heat flow and charge based on the obtained results.展开更多
S:Understanding how surface energy fluxes respond to environmental variables and how their components vary on daily and seasonal temporal scales are critical for understanding the ecological process of wetland ecosyst...S:Understanding how surface energy fluxes respond to environmental variables and how their components vary on daily and seasonal temporal scales are critical for understanding the ecological process of wetland ecosystem. In view of the fact that studies on surface energy flux over mire in China have been very limited, we have initiated a long-term latent and sensible heat flux (two main components of the surface energy balance) observation over mire in the Sanjiang Plain from June to October in 2004 with the eddy covariance technique. Results showed that the latent and sensible heat flux had large seasonal and diurnal variation during the period of measurement. Generally, latent heat flux between the mire wetland and the atmosphere reached the maximum value in June and then gradually decreased from June to October, whose daily mean fluxes were 9.83,8.00,7.33, 4.82 and 2.04 MJ/(m^2·d), respectively. By comparison, sensible heat flux changed unnoticeably with season change from June to October, which were 1.47,0.88,1.75, 1.61,1.33 MJ/(m^2·d) respectively. The diurnal variation of both latent and sensible heat flux varied noticeably within a day. After the sunrise, the latent and sensible heat flux increased and reached the maximum at noon (11:00-13:00). Then they decreased gradually and reached the minimum value during the nighttime. The patterns of temporal variation in latent and sensible heat flux were significantly controlled by environmental factors. The latent heat flux was linearly dependent on net radiation and increased with increasing vapour pressure deficit until the vapour pressure deficit surpassed 11 hPa. Wind speed effect on latent heat flux was more complicated and, in general, showed a positive correlation between them in daytime. The sensible heat flux was controlled mainly by air temperature difference between the land surface and the overlying air. However, when the temperature difference was larger than 0.3 ℃, it had no effect on the sensible heat flux. The study showed up the temporal variation of latent and sensible heat flux and how the environmental factors affected them.展开更多
A series of non-woven fabrics were fabricated by blending 5080 wt% of thermoregulated fibres containing n-eicosane, n-nonadecane or n-octadecane with 040wt% PET fibres and 020wt% PP fibres. The phase change properties...A series of non-woven fabrics were fabricated by blending 5080 wt% of thermoregulated fibres containing n-eicosane, n-nonadecane or n-octadecane with 040wt% PET fibres and 020wt% PP fibres. The phase change properties, thermal conductivity, thermal resistance, heat flux and inner temperature difference between wool felt and the thermoregulated non-woven fabrics of the non-woven fabrics were measured respectively. The thermo-regulated non-woven fabrics absorb heat at 2534℃ and release heat at 1025℃. The measured highest enthalpy of the non-woven is approximately 18J/g. During a heating process, heat flux of the non-woven fabrics is composed of three parts: heat absorbed by the cold textile touching the hot plate, heat transmitted from the hot plate to the cold plate, and the heat absorbed by PCM from the hot plate during the phase change process. The measured maximum inner temperature difference in a temperature rising process between the wool felt and the thermo-regulated non-woven fabric is approximately 8℃. The inner temperature difference (Tr-Ts>0) lasts 1645 min. By contrary, the measured maximum inner temperature difference in the temperature decreasing process is approximately-6.5℃. The inner temperature difference (Tr-Ts<0) lasts 1650 min. The temperature regulation properties are obviously observed.展开更多
运用夹点技术对加氢裂化装置的换热网络进行优化,利用Aspen Energy Analyzer V 8.4软件模拟换热网络曲线对换热网络的特点进行分析,提出相应的优化方案,并利用Aspen Hysys模拟软件对优化方案进行模拟。结果表明:该换热网络的夹点温度为1...运用夹点技术对加氢裂化装置的换热网络进行优化,利用Aspen Energy Analyzer V 8.4软件模拟换热网络曲线对换热网络的特点进行分析,提出相应的优化方案,并利用Aspen Hysys模拟软件对优化方案进行模拟。结果表明:该换热网络的夹点温度为147.2℃,装置换热网络最小热公用工程用量为7.72 MW,最小冷公用工程用量为8.39 MW,节能潜力仍有6.67 MW;通过采用新增1台换热器E 1(利旧),利用152℃的柴油给45.5℃的冷低分油换热的优化方案,可分别节约热、冷公用工程2.11,0.36 MW,热、冷公用工程节能效率分别为27.34%,4.29%。展开更多
介绍了中国计量科学研究院新研制的两台高精度钠热管固定点炉(SHPF-1、SHPF-2),并测量了其垂直温场.当这两台钠热管固定点炉的炉温分别控制在比铝凝固点低约2℃、3℃时,铝点容器温度计阱底部150 mm范围内温场均匀性分别为15 mK和11 mK,...介绍了中国计量科学研究院新研制的两台高精度钠热管固定点炉(SHPF-1、SHPF-2),并测量了其垂直温场.当这两台钠热管固定点炉的炉温分别控制在比铝凝固点低约2℃、3℃时,铝点容器温度计阱底部150 mm范围内温场均匀性分别为15 mK和11 mK,并与国外同类的钠热管固定点炉的技术指标进行比较.此外,分析了影响固定点炉等温性能的因素.
Abstract:
Two sodium heat-pipe fixed point furnaces (SHPF-1, SHPF-2) developed at the National Institute of Metrology (NIM) are described, and their vertical temperature uniformities are measured. When the temperatures of the these two furnaces are controlled about 2 ℃ and 3 ℃ respectively, below the freezing point of the aluminum, the largest temperature differences did not exceed 15 mK and 11 mK in a distance about 150mm along the reentrant well of the aluminum point cell, respectively. These temperature uniformities are compared with those of foreign similar sodium heat pipe furnaces. Additionally, factors influencing isothermal characteristics of fixed point furnaces are analyzed.展开更多
基金supported by the National Natural Science Foundation of China (Grant No. 40730952)the National Basic Research Program of China (Grant No. 2009CB421405)the Program of Knowledge Innovation for the third period, the Chinese Academy of Sciences (Grant No. KZCX2-YW-220), and IAP07414
文摘The present study investigates the difference in interdecadal variability of the spring and summer sensible heat fluxes over Northwest China by using station observations from 1960 to 2000. It was found that the spring sensible heat flux over Northwest China was greater during the period from the late 1970s to the 1990s than during the period from the 1960s to the mid-1970s. The summer sensible heat flux was smaller in the late 1980s through the 1990s than it was in the 1970s through the early 1980s. Both the spring and summer land-air temperature differences over Northwest China displayed an obvious interdecadal increase in the late 1970s. Both the spring and summer surface wind speeds experienced an obvious interdecadal weakening in the late 1970s. The change in the surface wind speed played a more important role in the interdecadal variations in sensible heat flux during the summer, whereas the change in the land-air temperature difference was more important for the interdecadal variations in sensible heat flux in the spring. This difference was related to seasonal changes in the mean land-air temperature difference and the surface wind speed. Further analysis indicated that the increase in the spring land surface temperature in Northwest China was related to an increase in surface net radiation.
基金supported by the National Basic Research Program of China(Grant No.2009CB421405)the National Natural Science Foundationof China(Grant Nos.40730952 and 40905027)+1 种基金the Program of Knowledge Innovation for the 3rd period of Chinese Academy of Sciences(Grant No.KZCX2-YW-220)IAP07414
文摘The present study compares seasonal and interdecadal variations in surface sensible heat flux over Northwest China between station observations and ERA-40 and NCEP-NCAR reanalysis data for the period 1960-2000. While the seasonal variation in sensible heat flux is found to be consistent between station observations and the two reanalysis datasets, both land-air temperatures difference and surface wind speed show remarkable systematic differences. The sensible heat flux displays obvious interdecadal variability that is season-dependent. In the ERA-40 data, the sensible heat flux in spring, fall, and winter shows interdecadal variations that are similar to observations. In the NCEP-NCAR reanalysis data, sensible heat flux variations are inconsistent with and sometimes even opposite to observations. While surface wind speeds from the NCEP-NCAR reanalysis data show interdecadal changes consistent with station observations, variations in land-air temperature difference differ greatly from the observed dataset. In terms of land-air temperature difference and surface wind speed, almost no consistency with observations can be identified in the ERA-40 data, apart from the land-air temperature difference in fall and winter. These inconsistencies pose a major obstacle to the application in climate studies of surface sensible heat flux derived from reanalysis data.
基金supported by the National Basic Research Program of China (Grant No. 2009CB421405)the National Natural Science Foundation of China (Grant Nos.40905027 and 40730952)Program of Knowledge Innovationfor the 3rd period of Chinese Academy of Sciences (Grant No.KZCX2-YW-220)
文摘The present study documents the variability of surface sensible heat flux over Northwest China using station observations for the period 1961 2000.It is found that the afternoon and nighttime sensible heat flux variations are remarkably different.The variability of the instant flux in the afternoon is much larger than in the nighttime.The afternoon and nighttime flux anomalies tend to be opposite.The diurnal and seasonal dependence of sensible heat flux variations is closely related to the diurnal cycle of mean land-air temperature difference.The relationship of sensible heat flux with land-air temperature difference based on the instant value differs from that based on the daily mean.The present study indicates the importance for the models to properly simulate mean land-air temperature difference and its diurnal and seasonal variations in order to capture surface sensible heat flux variability over Northwest China and predicts its plausible impacts on climate.
文摘Considering the continuous functioning of a power transformer under charge of high capacity of 50 MVA, predicted studies are proposed to be performed of their thermal behavior under perma nent and variable regimens of flow of charge, using noninvasive methods based in integral trans forms that measure and determine parameters of geometrical, analytical and physical type of the transformer. In before works, we have studied a basic geometry of a winding composed of high and low voltage sections with a uniform heat generation and heat convection boundary conditions. The heat conduction equation representing the phenomena of heat generation in a cylindrical structure was solved by using an integral transform. In this sense, this new study considers the basic geometry composed of a three cylindrical windings (high and low voltage turns) and a rec tangular core. Thus it is proposed to solve magnetic flow equations using integral transforms (Han kel transforms and Bessel integrals) in order to obtain the heat source distribution in the core due to the magnetization currents which are developed in function of the magnetic field flow equations. Based on this, it is proposed as a second step to use this heat source distribution to obtain the corresponding temperature distribution in the core by solving the cylindrical heat conduction equation for the core (cylindrical). Bearing this in mind, it is proposed finally to solve the 3D cylindrical heat conduction equation for the one winding using the calculated heat convection coefficients, the conductivity of the winding, behavior of the mineral oil and the non uniform winding heat generation predicted in recent researches. This equation will be solved by using integral methods (Radon, Hankel and Fourier transforms). This methodology will be useful to establish a new design of a power transformer based on the values of their integrals and the results that throw the inverse methods for this case. Finally if possible we will use the programs of Fluent and/or Phoenics for the validation of functional proposed models of prediction and prevention of heat flow and charge based on the obtained results.
文摘S:Understanding how surface energy fluxes respond to environmental variables and how their components vary on daily and seasonal temporal scales are critical for understanding the ecological process of wetland ecosystem. In view of the fact that studies on surface energy flux over mire in China have been very limited, we have initiated a long-term latent and sensible heat flux (two main components of the surface energy balance) observation over mire in the Sanjiang Plain from June to October in 2004 with the eddy covariance technique. Results showed that the latent and sensible heat flux had large seasonal and diurnal variation during the period of measurement. Generally, latent heat flux between the mire wetland and the atmosphere reached the maximum value in June and then gradually decreased from June to October, whose daily mean fluxes were 9.83,8.00,7.33, 4.82 and 2.04 MJ/(m^2·d), respectively. By comparison, sensible heat flux changed unnoticeably with season change from June to October, which were 1.47,0.88,1.75, 1.61,1.33 MJ/(m^2·d) respectively. The diurnal variation of both latent and sensible heat flux varied noticeably within a day. After the sunrise, the latent and sensible heat flux increased and reached the maximum at noon (11:00-13:00). Then they decreased gradually and reached the minimum value during the nighttime. The patterns of temporal variation in latent and sensible heat flux were significantly controlled by environmental factors. The latent heat flux was linearly dependent on net radiation and increased with increasing vapour pressure deficit until the vapour pressure deficit surpassed 11 hPa. Wind speed effect on latent heat flux was more complicated and, in general, showed a positive correlation between them in daytime. The sensible heat flux was controlled mainly by air temperature difference between the land surface and the overlying air. However, when the temperature difference was larger than 0.3 ℃, it had no effect on the sensible heat flux. The study showed up the temporal variation of latent and sensible heat flux and how the environmental factors affected them.
基金the financial supports from The Hong Kong Polytechnic University(the Area of Strategic Development Project,No A180) the National Natural Science Foundation of China(No50073015).
文摘A series of non-woven fabrics were fabricated by blending 5080 wt% of thermoregulated fibres containing n-eicosane, n-nonadecane or n-octadecane with 040wt% PET fibres and 020wt% PP fibres. The phase change properties, thermal conductivity, thermal resistance, heat flux and inner temperature difference between wool felt and the thermoregulated non-woven fabrics of the non-woven fabrics were measured respectively. The thermo-regulated non-woven fabrics absorb heat at 2534℃ and release heat at 1025℃. The measured highest enthalpy of the non-woven is approximately 18J/g. During a heating process, heat flux of the non-woven fabrics is composed of three parts: heat absorbed by the cold textile touching the hot plate, heat transmitted from the hot plate to the cold plate, and the heat absorbed by PCM from the hot plate during the phase change process. The measured maximum inner temperature difference in a temperature rising process between the wool felt and the thermo-regulated non-woven fabric is approximately 8℃. The inner temperature difference (Tr-Ts>0) lasts 1645 min. By contrary, the measured maximum inner temperature difference in the temperature decreasing process is approximately-6.5℃. The inner temperature difference (Tr-Ts<0) lasts 1650 min. The temperature regulation properties are obviously observed.
文摘介绍了中国计量科学研究院新研制的两台高精度钠热管固定点炉(SHPF-1、SHPF-2),并测量了其垂直温场.当这两台钠热管固定点炉的炉温分别控制在比铝凝固点低约2℃、3℃时,铝点容器温度计阱底部150 mm范围内温场均匀性分别为15 mK和11 mK,并与国外同类的钠热管固定点炉的技术指标进行比较.此外,分析了影响固定点炉等温性能的因素.
Abstract:
Two sodium heat-pipe fixed point furnaces (SHPF-1, SHPF-2) developed at the National Institute of Metrology (NIM) are described, and their vertical temperature uniformities are measured. When the temperatures of the these two furnaces are controlled about 2 ℃ and 3 ℃ respectively, below the freezing point of the aluminum, the largest temperature differences did not exceed 15 mK and 11 mK in a distance about 150mm along the reentrant well of the aluminum point cell, respectively. These temperature uniformities are compared with those of foreign similar sodium heat pipe furnaces. Additionally, factors influencing isothermal characteristics of fixed point furnaces are analyzed.