期刊文献+
共找到378篇文章
< 1 2 19 >
每页显示 20 50 100
Comparison of the rheological properties of four root canal sealers 被引量:1
1
作者 Seok Woo Chang Young-Kyu Lee +7 位作者 Qiang Zhu Won Jun Shon Woo Cheol Lee Kee Yeon Kum Seung Ho Baek In Bog Lee Bum-Soon Lim Kwang Shik Bae 《International Journal of Oral Science》 SCIE CAS CSCD 2015年第1期56-61,共6页
The flowability of a root canal sealer is clinically important because it improves the penetration of the sealer into the complex root canal system. The purpose of this study was to compare the flowabilities of four r... The flowability of a root canal sealer is clinically important because it improves the penetration of the sealer into the complex root canal system. The purpose of this study was to compare the flowabilities of four root canal sealers, measured using the simple press method (ISO 6876), and their viscosities, measured using a strain-controlled rheometer. A newly developed, calcium phosphate-based root canal sealer (Capseal) and three commercial root canal sealers (AH Plus, Sealapex and Pulp Canal Sealer EWT) were used in this study. The flowabilities of the four root canal sealers were measured using the simple press method (n= 5) and their viscosities were measured using a strain-controlled rheometer (n=5). The correlation between these two values was statistically analysed using Spearman's correlation test. The flow diameters and the viscosities of the root canal sealers were strongly negatively correlated (p= -0.8618). The viscosity of Pulp Canal Sealer EWT was the lowest and increased in the following order: AH Plus〈Sealapex〈Capseal (P〈0.05). All of the tested root canal sealers showed characteristic time- and temperature-dependent changes in their rheological properties. The viscosities measured using the strain-controlled rheometer were more precise than the flowabilities measured using the simple press method, suggesting that the rheometer can accurately measure the rheological properties of root canal sealers. 展开更多
关键词 Capseal rheological property root canal sealer strain-controlled rheometer
下载PDF
Comparison of Apical Leakage in Root Canal Obturation Using Bioceramic and Polydimethylsiloxane Sealer (<i>In Vitro</i>) 被引量:1
2
作者 Bina Amanda Endang Suprastiwi Munyati Usman 《Open Journal of Stomatology》 2018年第1期24-34,共11页
Background: One of the ideal properties of a root canal sealer is to have a good sealing ability, especially at the apical third of the root. Objective: To evaluate the comparison of the apical leakage between obturat... Background: One of the ideal properties of a root canal sealer is to have a good sealing ability, especially at the apical third of the root. Objective: To evaluate the comparison of the apical leakage between obturation using bioceramic sealer (BS) and polydimethylsiloxane sealer (PS). Materials and Methods: Thirty-six mandibular premolars were equally divided into two groups and were obturated with single cone technique. The sealers used for Group I and Group II were BS and PS respectively. After obturation, the samples were incubated (37&deg;C, 24 h), sealed with two coats of nail polish except for 2 mm from the apex, submerged in the Indian ink for 7 days, decalcified, dehydrated, and made transparent according to Robertson technique. Dye penetration was evaluated under stereomicroscope. Samples without dye penetration were given score 0, dye penetration ≤ 0.5 mm were given score 1, 0.51 - 1 mm were given score 2, and >1 mm were given score 3. Result: The largest proportion distribution in BS group was at the score 1 (55.6%), whereas in PS group was at the score 2 (44.4%). Conclusion: Bioceramic sealer showed similar apical leakage to polydimethylsiloxane sealer. Clinical Relevance: Based on this study, bioceramic sealer can be recommended to be used as sealer with low level of apical leakage as well as polydimethylsiloxane sealer. 展开更多
关键词 BIOCERAMIC sealer POLYDIMETHYLSILOXANE sealer APICAL Leakage
下载PDF
Conservative endodontic management using a calcium silicate bioceramic sealer for delayed root fracture:A case report and review of the literature 被引量:2
3
作者 Pei Zheng Zhen-Yu Shen Bai-Ping Fu 《World Journal of Clinical Cases》 SCIE 2021年第8期1835-1843,共9页
BACKGROUND The success rate of conservative endodontic management for root fracture varies greatly based on different methods used.It has been rarely reported that calcium silicate-based materials are applied in root ... BACKGROUND The success rate of conservative endodontic management for root fracture varies greatly based on different methods used.It has been rarely reported that calcium silicate-based materials are applied in root fracture treatment.CASE SUMMARY A 38-year-old male patient presented with spontaneous pain from the upper left anterior teeth for 1 wk.The spontaneous pain was subsequently relieved,but pain on mastication persisted for 3 d.The patient had a dental trauma from a boxing match 15 years ago.Cone beam computed tomography showed that the maxillary left central incisor had oblique fracture lines and a radiolucent lesion around the fracture line.The tooth was diagnosed with an oblique root fracture with no healing and symptomatic apical periodontitis.In the following conservative endodontic management,the coronal and apical fragments of the canal both were chemo-mechanically prepared and obturated using a single cone gutta-percha with iRoot SP(Innovative BioCreamix Inc,Vancouver,Canada),a new calcium silicate-based bioceramic root canal sealer.At follow-ups at 1,6,12,and 24 mo,the patient was asymptomatic and the radiolucency around the fracture line was healing radiographically.CONCLUSION Conservative root canal treatment is an alternative treatment in some cases of oblique root fracture with no healing.The application of bioceramic sealers and single core obturation techniques may also be essential to obtain an excellent outcome. 展开更多
关键词 Oblique root fracture Endodontic treatments Single core obturation iRoot SP Calcium silicate-based sealer Case report
下载PDF
Enhanced Work Function of Al-Doped Zinc-Oxide Thin Films by Oxygen Inductively Coupled Plasma Treatment 被引量:1
4
作者 李泽斌 吴忠航 +6 位作者 居家奇 何孔多 陈枕流 杨曦露 颜航 区琼荣 梁荣庆 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第1期79-82,共4页
Al-doped zinc-oxide (AZO) thin films treated by oxygen and chlorine inductively coupled plasma (ICP) were compared. Kelvin probe (KP) and X-ray photoelectron spectroscopy (XPS) were employed to characterize th... Al-doped zinc-oxide (AZO) thin films treated by oxygen and chlorine inductively coupled plasma (ICP) were compared. Kelvin probe (KP) and X-ray photoelectron spectroscopy (XPS) were employed to characterize the effect of treatment. The results of KP measurement show that the surface work function of AZO thin films can increase up to 5.92 eV after oxygen ICP (O-ICP)'s treatment, which means that the work function was increased by at least 1.1 eV. However, after the treatment of chlorine ICP (CI-ICP), the work function increased to 5.44 eV, and the increment was 0.6 eV. And 10 days later, the work function increment was still 0.4 eV after O-ICP's treatment, while the work function after Cl-ICP's treatment came back to the original value only after 48 hours. The XPS results suggested that the O-ICP treatment was more effective than CI-ICP for enhancing the work function of AZO films, which is well consistent with KP results. 展开更多
关键词 oxygen inductively coupled plasma Al-doped zinc-oxide (AZO) work function
下载PDF
Push-out Bond Strength of Self-adhesive Methacrylate Resin-based Sealers to Root Dentin
5
作者 孙燕 李宇红 樊明文 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2014年第1期108-113,共6页
This study examined the adhesive strength of two self-adhesive methacrylate resin-based sealers(MetaSEAL and RealSeal SE) to root dentin and compared them with RealSeal and AH Plus in properties. A total of 48 extra... This study examined the adhesive strength of two self-adhesive methacrylate resin-based sealers(MetaSEAL and RealSeal SE) to root dentin and compared them with RealSeal and AH Plus in properties. A total of 48 extracted human single-rooted teeth were used to prepare the 0.9-mm thick longitudinal tooth slice(each per tooth). Standardized simulated canal spaces of uniform dimensions were prepared in the middle of radicular dentin. After treated with 5.25% sodium hypochlorite(NaOCl) and 17% EDTA, tooth slices were allocated randomly to four groups(n=12) in terms of different sealers used: MetaSEAL, RealSeal SE, RealSeal, and AH plus groups. The simulated canal spaces were obturated with different sealers in each group. There were 10 slabs with 20 simulated canal spaces(n=20) used in each group for push-out testing. The failure modes and the ultrastructures of fractured sealer-dentin interfaces were examined. The remaining 2 slabs in each group underwent partial demineralization for observation of the ultrastructure of resin tags. The results showed that the push-out bond strength was 12.01±4.66 MPa in MetaSEAL group, significantly higher than that in the other three groups(P0.05). Moreover, no statistically significant differences were noted in the push-out bond strength between RealSeal SE(5.43±3.68 MPa) and AH Plus(7.34±2.83 MPa) groups and between RealSeal SE and RealSeal(2.93±1.76 MPa) groups(P0.05). Mixed failures were predominant in the fractured sealer-dentin interfaces in MetaSEAL and AH Plus groups, while adhesive failures were frequently seen in RealSeal SE and RealSeal groups. In conclusion, after complete removal of the smear layer, MetaSEAL showed superior bond ability to root dentin. The RealSeal SE is applicable in clinical practice, with its adhesive strength similar to that of AH Plus. The self-adhesive methacrylate resin-based sealer holds promise for use in endodontic treatment. 展开更多
关键词 endodontic sealer push-out bond strength adhesive interface raidicular dentin
下载PDF
Zinc-oxide/PDMS-clad tapered fiber saturable absorber for passively mode-locked erbium-doped fiber laser
6
作者 F D Muhammad S A S Husin +3 位作者 E K Ng K Y Lau C A C Abdullah M A Mahdi 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第5期384-389,共6页
We propose and demonstrate a passively mode-locked erbium-doped fiber laser(EDFL)based on zinc-oxide/polydimethylsiloxane(ZnO/PDMS)saturable absorber(SA)that evanescently interacts with the light on a tapered fiber.Th... We propose and demonstrate a passively mode-locked erbium-doped fiber laser(EDFL)based on zinc-oxide/polydimethylsiloxane(ZnO/PDMS)saturable absorber(SA)that evanescently interacts with the light on a tapered fiber.The ZnO/PDMS composite is coated on the whole surface of the tapered fiber to guarantee the maximum efficiency of the SA device,with a measured insertion loss of 0.87 dB and a modulation depth of 6.4%.The proposed laser can generate soliton mode-locking operation at a threshold power of 33.07 mW.The generated output pulse yields a repetition rate and pulse width of 9.77 MHz and 1.03 ps,respectively.These results indicate that the proposed ZnO/PDMS-clad tapered fiber could be useful as an efficient,compatible,and low-cost SA device for ultrafast laser applications. 展开更多
关键词 zinc-oxidE saturable absorber tapered fiber MODE-LOCKED fiber laser
下载PDF
金属离子对固化封尘剂沉降特性的影响
7
作者 吉日格勒 孙鑫 《洁净煤技术》 CAS CSCD 北大核心 2024年第S01期481-485,共5页
金属离子是固化封尘剂配置和使用过程中影响除尘效果的主要影响因素,研究了固化封尘剂沉降过程中质量浓度、金属离子浓度、金属离子种类对其悬浮液颗粒表面电位和稳定性的影响。结果表明,随封尘剂质量浓度的增加,悬浮液中固体颗粒表面... 金属离子是固化封尘剂配置和使用过程中影响除尘效果的主要影响因素,研究了固化封尘剂沉降过程中质量浓度、金属离子浓度、金属离子种类对其悬浮液颗粒表面电位和稳定性的影响。结果表明,随封尘剂质量浓度的增加,悬浮液中固体颗粒表面负电位增加,体系的稳定性增强;金属阳离子通过影响悬浮液固体颗粒表面负电位而影响体系的稳定性,阳离子浓度越大,封尘剂悬浮液稳定性系数TSI值越大,不同种类的阳离子对封尘剂悬浮液影响程度不同,相同浓度下阳离子对封尘剂悬浮液失稳作用强度顺序为Fe^(3+)>Fe^(2+)>Ca^(2+)>Na^(+)。 展开更多
关键词 封尘剂沉降 金属离子 悬浮液稳定性
下载PDF
2种根管充填方式下即刻和延迟桩道预备对根尖微渗漏影响的体外研究
8
作者 斯灵 江龙 朱亚琴 《实用口腔医学杂志》 CAS CSCD 北大核心 2024年第6期793-798,共6页
目的:比较2种根管充填时即刻和延迟桩道预备对根尖微渗漏的影响。方法:收集60颗新鲜拔除的单根管前磨牙,截冠后拔髓并使用M3-Pro系统进行根管预备,随机进行AH-Plus热牙胶根管充填(A组,30颗)和iRoot SP单尖法充填(B组,30颗)。再将A或B组... 目的:比较2种根管充填时即刻和延迟桩道预备对根尖微渗漏的影响。方法:收集60颗新鲜拔除的单根管前磨牙,截冠后拔髓并使用M3-Pro系统进行根管预备,随机进行AH-Plus热牙胶根管充填(A组,30颗)和iRoot SP单尖法充填(B组,30颗)。再将A或B组中的样本进一步随机分为:A1和B1组(延迟桩道预备,各10颗);A2和B2组(即刻桩道预备,各10颗);A3和B3组(对照组,各10颗)。全部样本均保留根尖5 mm的充填材料。染色法比较各组样本根尖微渗漏情况。结果:各组根方染料深度(mm)均值分别为:A1组3.986±0.500,A2组3.382±0.806,A3组2.178±0.554(P<0.05);B1组3.844±0.877,B2组3.416±0.579,B3组1.897±0.217(P<0.05)。B1和B2组间比较,P>0.05;A1与B1组间比较P>0.05;A2和B2组间比较,P>0.05。结论:2种根管充填方式下桩道预备均能影响根尖微渗漏,即刻桩道预备较延迟桩道预备对根尖微渗漏的影响更小,尤其是热牙胶根管充填存在显著差异;在即刻桩道预备和延迟桩道预备中,两种根管充填方式对根尖微渗漏的影响无显著差异。 展开更多
关键词 即刻桩道预备 延迟桩道预备 根尖微渗漏 AH-Plus根管充填糊剂 iRoot SP根管封闭剂
下载PDF
GuttaFlow Bioseal封闭剂对椭圆形根管抗垂直折裂能力的影响
9
作者 迪丽娜尔·库热西 杨娅 何宏 《上海口腔医学》 CAS 2024年第3期250-254,共5页
目的:探讨GuttaFlow Bioseal根管封闭剂对椭圆形根管抗垂直折裂能力的影响。方法:CBCT扫描60颗正畸减数拔除的下颌单根前磨牙,当距离根尖5 mm处颊舌管径大于等于近远中管径2倍时,为符合筛选条件的椭圆形根管。使用Protaper系统将30颗椭... 目的:探讨GuttaFlow Bioseal根管封闭剂对椭圆形根管抗垂直折裂能力的影响。方法:CBCT扫描60颗正畸减数拔除的下颌单根前磨牙,当距离根尖5 mm处颊舌管径大于等于近远中管径2倍时,为符合筛选条件的椭圆形根管。使用Protaper系统将30颗椭圆形根管的离体牙预备至F2,随机分为GuttaFlow Bioseal充填组和iRoot SP充填组,每组分别用热垂直加压法、冷牙胶侧压法及单尖法充填根管。选取5颗离体牙作为阴性对照组。将充填完好的牙根在37℃、100%湿度的恒温箱中保存14天后,垂直放入自聚合丙烯酸树脂圆柱模型中,随后将样本固定于万能试验机的下板,用直径4 mm的球以1 mm/min的速度垂直向下加压,直至出现折裂,用N记载负载值。采用SPSS 29.0软件包对数据进行t检验与单因素方差分析,组间进行LSD分析,显微镜下分析断裂模式。结果:GuttaFlow Bioseal充填组及iRoot SP充填组相比无显著差异(P=0.321),不同组间抗垂直折裂能力存在显著差异(P<0.05)。使用热垂直加压充填法与单尖法时,GuttaFlow Bioseal充填后的样本牙抗垂直折裂能力显著高于iRoot SP,而使用冷侧压充填法时的抗垂直折裂能力显著低于iRoot SP。结论:使用热垂直加压充填法和单尖法充填根管时,GuttaFlow Bioseal有提高牙根抗垂直折裂能力的潜力,但仍需更多临床试验予以验证。 展开更多
关键词 GuttaFlow Bioseal 垂直折裂 根管封闭剂 椭圆形根管
下载PDF
静态破碎剂膨胀性能测试及施工工艺优化
10
作者 吴俊杰 袁瑞甫 +2 位作者 解帅帅 程高宇 李辉 《地下空间与工程学报》 CSCD 北大核心 2024年第6期2034-2044,共11页
静态破碎剂已经广泛应用于煤矿开采等领域,存在膨胀应力试验繁琐、上行孔封孔困难、施工难度大等问题。采用排水法测试膨胀率时变曲线,结合膨胀应力曲线,获取膨胀率-膨胀应力模型,快速获得膨胀性能参数;自主研发管式封孔器,简化施工工艺... 静态破碎剂已经广泛应用于煤矿开采等领域,存在膨胀应力试验繁琐、上行孔封孔困难、施工难度大等问题。采用排水法测试膨胀率时变曲线,结合膨胀应力曲线,获取膨胀率-膨胀应力模型,快速获得膨胀性能参数;自主研发管式封孔器,简化施工工艺,提高封孔效率;通过4种水灰比流动性试验和泵送试验,选取0.34作为工程用水灰比。研究结果表明:膨胀率和膨胀应力正相关,通过膨胀率试验及其对应的膨胀应力曲线,可以快速获取不同水灰比的膨胀性能参数,简化膨胀应力试验;管式封孔器施工工艺简单、适应性强、封孔效果好;所选水灰比流动性较好,泵送方便,注浆设备轻便、体积小,输送管路内浆体泵送距离达8 m,能够满足井下施工要求。优化后的工艺,施工效率显著提高,满足复杂的地质及施工条件要求。 展开更多
关键词 排水法 水灰比 流动度 管式封孔器 上行孔施工工艺
下载PDF
固化封尘剂智能加药在线监测系统的设计
11
作者 尚书宏 王皓鹏 +3 位作者 纪兴 王鹏飞 徐宏祥 孙鑫 《煤炭加工与综合利用》 CAS 2024年第2期7-11,18,共6页
传统的封尘剂管理和监测方法存在诸多局限性和问题,开发了一种固化封尘剂智能加药在线监测系统,介绍了该系统的设计、搭建、测试及结果。测试结果表明,该系统可以有效地监测固化封尘剂的加药量,并能根据生产需求自动调整药剂投放量,提... 传统的封尘剂管理和监测方法存在诸多局限性和问题,开发了一种固化封尘剂智能加药在线监测系统,介绍了该系统的设计、搭建、测试及结果。测试结果表明,该系统可以有效地监测固化封尘剂的加药量,并能根据生产需求自动调整药剂投放量,提高煤场物料密度和装载效率,减少煤炭流失,保护周边环境。 展开更多
关键词 选煤厂 固化封尘剂 在线监测系统 智能加药 设计
下载PDF
生物陶瓷封闭剂nRoot和生物陶瓷牙胶尖的根尖封闭性研究
12
作者 王培儒 牛一山 +1 位作者 武万超 韩宇环 《中国美容医学》 CAS 2024年第7期60-64,共5页
目的:体外评价国产新型生物陶瓷根管封闭剂nRoot的根尖封闭性以及应用生物陶瓷根管封闭剂时生物陶瓷牙胶尖的根尖封闭性,为临床材料选择提供理论依据。方法:选取单根管的离体前磨牙,自釉牙骨质界处截去牙冠,随机分为四个实验组和两个对... 目的:体外评价国产新型生物陶瓷根管封闭剂nRoot的根尖封闭性以及应用生物陶瓷根管封闭剂时生物陶瓷牙胶尖的根尖封闭性,为临床材料选择提供理论依据。方法:选取单根管的离体前磨牙,自釉牙骨质界处截去牙冠,随机分为四个实验组和两个对照组。通过逐步深入技术进行根管预备,然后采用Martin TroPe推介的生物陶瓷封闭剂改良热牙胶垂直加压充填技术进行根管充填。A组:nRoot根管封闭剂联合生物陶瓷牙胶尖;B组:nRoot根管封闭剂联合普通牙胶尖;C组:iRoot SP根管封闭剂联合生物陶瓷牙胶尖;D组:iRoot SP根管封闭剂联合普通牙胶尖;E组和F组分别为阳性对照组和阴性对照组。通过染料渗透法和扫描电镜法分别观测各组根尖封闭性情况,染料渗透长度越长,微缝隙越宽,表示根尖封闭性越差。结果:染料渗透实验结果显示,A组(2.455±0.137)mm,B组(2.830±0.148)mm,C组(2.426±0.130)mm,D组(2.774±0.163)mm。经方差分析得出,iRoot SP和nRoot差异无统计学意义(P>0.05);生物陶瓷牙胶尖和普通牙胶尖差异有统计学意义(P<0.05),且生物陶瓷牙胶尖染料渗透平均值低于普通牙胶尖;根管封闭剂与牙胶尖交互效应不显著(P>0.05)。扫描电镜结果显示,各组充填材料与牙体组织结合界面均可见大小不等的微缝隙,其中使用普通牙胶尖的B组和D组中,微缝隙较宽,而使用生物陶瓷牙胶尖的A组和C组中,微缝隙相对较小;B组与D组之间,A组与C组之间,微缝隙宽度均没有明显区别。结论:①国产新型生物陶瓷根管封闭剂nRoot具有与进口生物陶瓷根管封闭剂iRoot SP相似的根尖封闭性;②应用生物陶瓷根管封闭剂时,生物陶瓷牙胶尖的根尖封闭性优于普通牙胶尖;③充填材料中根管封闭剂和牙胶尖对根尖封闭性的影响相互独立,互不干扰。 展开更多
关键词 nRoot根管封闭剂 iRoot SP根管封闭剂 生物陶瓷牙胶尖 普通牙胶尖 根尖封闭性
下载PDF
根管再治疗过程中冲洗剂清除硅酸钙基根管封闭剂效果的研究进展
13
作者 张波 李霞 杨梦绮 《国际口腔医学杂志》 CAS CSCD 北大核心 2024年第4期475-482,共8页
近年来硅酸钙基根管封闭剂因其优异的粘接封闭性、生物相容性等特性,在根管治疗中得到广泛应用。其优越的粘接封闭性提高了根管治疗的效果,但当根管治疗失败需要再治疗时,目前的常规根管再治疗方法以及机械预备和化学冲洗的技术改进难... 近年来硅酸钙基根管封闭剂因其优异的粘接封闭性、生物相容性等特性,在根管治疗中得到广泛应用。其优越的粘接封闭性提高了根管治疗的效果,但当根管治疗失败需要再治疗时,目前的常规根管再治疗方法以及机械预备和化学冲洗的技术改进难以有效地清除硅酸钙基根管封闭剂,根管再治疗的成功率随之受到挑战。因此本文聚焦于冲洗剂对硅酸钙基根管封闭剂的溶解作用,从物理溶解和化学溶解两方面对冲洗剂成分清除硅酸钙基根管封闭剂的能力进行综述,以期为临床上选择有效去除硅酸钙基根管封闭剂的根管冲洗剂,以及探索适宜的根管冲洗策略提供新思路。 展开更多
关键词 硅酸钙基根管封闭剂 冲洗剂 物理溶解 化学溶解 溶解度
下载PDF
长纤维抗裂复合封层机行走与撒(洒)布系统协同控制
14
作者 李志勇 焦生杰 +1 位作者 徐信芯 张佳乐 《液压与气动》 北大核心 2024年第7期22-32,共11页
为解决长纤维抗裂复合封层机在作业过程中出现的撒(洒)布不均匀问题,提出了一种模糊分数PID协同控制方法,采用分数阶PID控制器,实现了长纤维抗裂复合封层机行走与撒布系统的协同控制。结合模糊控制规则,对分数阶PID参数进行了在线实时优... 为解决长纤维抗裂复合封层机在作业过程中出现的撒(洒)布不均匀问题,提出了一种模糊分数PID协同控制方法,采用分数阶PID控制器,实现了长纤维抗裂复合封层机行走与撒布系统的协同控制。结合模糊控制规则,对分数阶PID参数进行了在线实时优化,提升了系统的整体控制性能。通过Simulink仿真实验,对比了该方法与传统PID控制器的综合性能。结果表明:所提控制器在行走和撒布过程中的响应速度、超调量及稳态误差等方面均显著优于传统PID控制器;并通过实车试验平台,对所提控制方法进行了试验验证,成功实现了长纤维抗裂复合封层机行走过程中纤维、沥青、碎石的协同控制,为长纤维抗裂复合封层机的行走与撒(洒)布系统协同控制领域提供了新的研究思路。 展开更多
关键词 长纤维抗裂复合封层机 行走与撒(洒)布系统 模糊分数阶控制 SIMULINK仿真 实车试验平台
下载PDF
终末冲洗液对根管封闭剂牙本质小管渗透性影响的体外研究
15
作者 李诗雅 黄辉 +5 位作者 王利娟 汤晨 周燕萍 杨慧 潘晓婷 李慧 《牙体牙髓牙周病学杂志》 2024年第8期456-461,共6页
目的:比较终末冲洗液(Octenisept^(R)、2%Chlorhexidine、5.25%NaClO、2.5%NaClO、1%NaClO、Saline)对两种根管封闭剂(iRoot SP、AH-Plus)的牙本质小管渗透性的影响。探讨最佳的终末冲洗液和根管封闭剂配伍。方法:收集因正畸拔除的单根... 目的:比较终末冲洗液(Octenisept^(R)、2%Chlorhexidine、5.25%NaClO、2.5%NaClO、1%NaClO、Saline)对两种根管封闭剂(iRoot SP、AH-Plus)的牙本质小管渗透性的影响。探讨最佳的终末冲洗液和根管封闭剂配伍。方法:收集因正畸拔除的单根管前磨牙72个,截冠标准化牙根长度为(14±0.5)mm,用TF镍钛系统根管预备。根据不同终末冲洗液随机分为6组(n=12)进行终末冲洗,A组Octenisept?,B组2%Chlorhexidine,C组5.25%NaClO,D组2.5%NaClO,E组1%NaClO,F组Saline。充填时,根据不同的根管封闭剂再分为2个亚组(n=6),1组iRoot SP,2组AH-Plus,封闭剂染色,单尖法充填根管。距离根尖2 mm,5 mm,8 mm处各制备0.1 mm厚的切片,置于共聚焦激光显微镜下观察,分析并测量封闭剂的牙本质小管平均最大渗透深度和渗透面积比。结果:所有样本根冠、中、尖三个部位均能观察到根管封闭剂渗入牙本质小管。3个部位之间的渗透性分布(渗透距离、渗透面积)具有显著差异(P<0.001)。牙本质小管最深渗透距离方面,无论是何种根管封闭剂,在根冠部和根中部,5.25%NaClO组显著高于NS组(P<0.05);在根尖部,NaClO组均高于其余组(P<0.05)。牙本质小管平均渗透面积方面,在所有根管段,封闭剂为iRoot SP时,高浓度NaClO组(5.25%、2.5%)显著大于其余组(P<0.05);封闭剂为AH-Plus时,在所有根管段,高浓度NaClO组显著高于NS组(P<0.05)。结论:高浓度NaClO终末冲洗的牙本质小管渗透表现较佳;封闭剂iRoot SP的牙本质小管渗透面积稍优于AH-Plus;5.25%NaClO终末冲洗配合iRoot SP渗透性效果优于其它组合。 展开更多
关键词 根管治疗 终末冲洗液 根管封闭剂 牙本质小管渗透性
下载PDF
不同根管充填材料在慢性根尖周炎患者根管充填术中的应用效果
16
作者 王晓敏 郭芳 田莹 《国际医药卫生导报》 2024年第23期3910-3914,共5页
目的比较AH-Plus根管充填材料与iRoot SP根管充填材料在慢性根尖周炎患者根管治疗术中的应用效果。方法前瞻性研究,选取2021年5月至2022年10月在延安大学附属医院牙体牙髓病科治疗的慢性根尖周炎患者90例作为研究对象,利用随机数字表法... 目的比较AH-Plus根管充填材料与iRoot SP根管充填材料在慢性根尖周炎患者根管治疗术中的应用效果。方法前瞻性研究,选取2021年5月至2022年10月在延安大学附属医院牙体牙髓病科治疗的慢性根尖周炎患者90例作为研究对象,利用随机数字表法分为对照组(45例)和观察组(45例)。对照组男24例、女21例,年龄(28.14±6.02)岁,病程(3.26±0.92)个月,接受根管治疗术时应用AH-Plus根管充填材料联合热牙胶垂直加压填充;观察组男22例、女23例,年龄(26.55±5.78)岁,病程(3.45±0.79)个月,接受根管治疗术时应用iRoot SP根管充填材料联合热牙胶垂直加压填充。对比两组患者疗效、疼痛评分[视觉模拟疼痛评分(VAS)]、治疗前后咀嚼功能及治疗满意度。统计学方法采用t检验、χ^(2)检验。结果观察组治疗总有效率为97.78%(44/45),高于对照组的73.33%(33/45),差异有统计学意义(χ^(2)=10.879,P<0.001)。观察组术后12、24、72 h的VAS评分均低于对照组[(1.52±0.19)分比(2.35±0.26)分、(2.65±0.31)分比(3.80±0.29)分、(3.29±0.20)分比(4.15±0.23)分],差异均有统计学意义(t=15.142、18.173、18.928,均P<0.05)。治疗前,两组患者咀嚼效率比较,差异无统计学意义(P>0.05);治疗后,观察组咀嚼效率高于对照组[(85.21±11.22)%比(72.76±10.23)%],差异有统计学意义(t=5.500,P<0.05)。观察组治疗总满意度为95.56%(43/45),高于对照组的77.78%(35/45),差异有统计学意义(χ^(2)=6.154,P=0.013)。结论与AH-Plus根管充填材料相比,iRoot SP根管充填材料在慢性根尖周炎患者根管充填治疗中表现出更好的治疗效果,可降低术后疼痛感,改善咀嚼功能,同时患者治疗满意度也有显著提升。 展开更多
关键词 根管治疗术 慢性根尖周炎 iRoot SP根管充填材料 AH-Plus根管充填材料
下载PDF
不同终末冲洗方式对生物陶瓷根管封闭剂的影响
17
作者 伏炜皓 黄馨慧 +1 位作者 张宗豪 吕红兵 《牙体牙髓牙周病学杂志》 2024年第12期696-703,708,共9页
目的:比较不同终末冲洗方式(注射器冲洗、被动超声荡洗、新型声波活化荡洗EDDY以及光子诱导光声流技术)对iRoot SP根管封闭剂粘接强度和牙本质小管渗透性的影响,探讨最佳的根管辅助冲洗装置。方法:选取58个单根离体前磨牙随机分为4组。... 目的:比较不同终末冲洗方式(注射器冲洗、被动超声荡洗、新型声波活化荡洗EDDY以及光子诱导光声流技术)对iRoot SP根管封闭剂粘接强度和牙本质小管渗透性的影响,探讨最佳的根管辅助冲洗装置。方法:选取58个单根离体前磨牙随机分为4组。扫描电子显微镜(SEM)观察根管壁玷污层以及牙本质小管暴露情况;推出实验检测粘接强度;共聚焦激光扫描显微镜(CLSM)评估根管封闭剂渗透性。结果:扫描电镜显示SNI组牙本质小管开口大部分被碎屑覆盖,PUI组牙本质小管开口较少,而EDDY组和PIPS组牙本质小管开口表面光滑。与SNI和PUI相比,EDDY和PIPS提高了iRoot SP的粘接强度和渗透深度。结论:SNI、PUI、EDDY、PIPS可部分清除牙本质碎屑,开放牙本质小管。与SNI和PUI相比,EDDY和PIPS提高了粘接强度和小管渗透性,且EDDY更方便、更经济,具有临床应用价值。EDDY具有临床推广应用的潜力。 展开更多
关键词 活化荡洗 粘接强度 封闭剂渗透 根管封闭剂
下载PDF
白车身覆盖件折边胶泡问题分析与控制策略
18
作者 胡浩 姚建玲 +1 位作者 宋明 张剑 《汽车电器》 2024年第8期94-96,99,共4页
文章对北京现代汽车有限公司焊装车间折边胶泡问题进行分析讨论,按照制造工艺流程,结合折边工艺特点,从人、机、料、法、环方面对胶泡问题产生的主要因素进行分析,并结合实际生产过程验证的参数,提出解决措施,制定胶泡问题的预防方案,... 文章对北京现代汽车有限公司焊装车间折边胶泡问题进行分析讨论,按照制造工艺流程,结合折边工艺特点,从人、机、料、法、环方面对胶泡问题产生的主要因素进行分析,并结合实际生产过程验证的参数,提出解决措施,制定胶泡问题的预防方案,为有效预防和解决胶泡问题提供一定的指导作用。 展开更多
关键词 胶泡 折边胶 折边工艺 控制 白车身
下载PDF
三种根管封闭剂根尖封闭性能的体外研究
19
作者 杜丽娟 李莎 +1 位作者 许倩 冯明 《口腔材料器械杂志》 2024年第3期145-149,共5页
目的在体外环境下比较HiFlow、iRoot SP、AH Plus 3种根管封闭剂的根尖封闭性能,以评价新型生物陶瓷类根管封闭剂HiFlow的应用效果。方法选取46个单根前磨牙,随机分为3个实验组(n=12)和一个对照组(n=10),实验组分别用HiFlow封闭剂、iRoo... 目的在体外环境下比较HiFlow、iRoot SP、AH Plus 3种根管封闭剂的根尖封闭性能,以评价新型生物陶瓷类根管封闭剂HiFlow的应用效果。方法选取46个单根前磨牙,随机分为3个实验组(n=12)和一个对照组(n=10),实验组分别用HiFlow封闭剂、iRoot SP封闭剂、AH Plus封闭剂配合牙胶尖行单尖法充填;对照组只用牙胶尖行单尖法充填。每组随机选取10个样本,使用染料渗透法对样本处理后,在体视显微镜下测量染料渗透长度,比较各组染料渗透长度。测量并比较不同组根尖微渗漏水平。剩余的实验组样本横切后用扫描电子显微镜观察截面。结果HiFlow组、iRoot SP组、AH Plus组和对照组的根管内均有染料渗入,染料渗透长度依次为(1.027±0.04)、(1.079±0.05)、(1.132±0.12)和(2.46±0.75)mm。3个实验组之间的染料渗透长度差异均无统计学意义(P>0.05),实验组染料渗透长度均明显小于对照组(P<0.05)。通过扫描电镜观察到3组根管封闭剂与根管壁牙本质之间均有间隙,AH Plus组的缝隙最大,HiFlow组的缝隙最小。结论3种根管封闭剂均不能完全封闭根管,其中HiFlow根尖封闭性能相对最佳。 展开更多
关键词 根管封闭剂 HiFlow封闭剂 iRoot SP封闭剂 AH Plus封闭剂 根尖微渗漏
下载PDF
iRoot SP封闭剂单尖法根管充填治疗牙髓根尖周病的临床效果
20
作者 钟琳 张良付 +3 位作者 唐芝羲 钟苑 鲁铭炜 胡雯 《中国当代医药》 CAS 2024年第33期92-95,共4页
目的探讨iRoot SP封闭剂单尖法根管充填治疗牙髓根尖周病的临床效果。方法选取2023年1月至2024年1月湖南中医药大学口腔医学院80例牙髓根尖周病患者作为研究对象,按照随机数字表法分为研究组和对照组,每组各40例。研究组行iRoot SP封闭... 目的探讨iRoot SP封闭剂单尖法根管充填治疗牙髓根尖周病的临床效果。方法选取2023年1月至2024年1月湖南中医药大学口腔医学院80例牙髓根尖周病患者作为研究对象,按照随机数字表法分为研究组和对照组,每组各40例。研究组行iRoot SP封闭剂单尖法根管充填,对照组行AH Plus结合热塑牙胶垂直加压充填。比较两组患者根管填充效果、单根管填充时间、疼痛程度、牙周指标。结果两组患者根管填充效果比较,差异无统计学意义(P>0.05);研究组单根管填充时间短于对照组,差异有统计学意义(P<0.05);治疗后7 d,两组患者视觉模拟评分法(VAS)评分均低于本组治疗前,且研究组VAS评分低于对照组,差异有统计学意义(P<0.05);治疗后3个月,两组患者菌斑指数(PI)、探诊出血指数(PBI)指标均低于本组治疗前,牙周探诊深度(PD)、临床附着水平(CAL)指标均短于本组治疗前,且研究组PI、PBI指标均低于对照组,PD、CAL指标均短于对照组,差异有统计学意义(P<0.05)。结论iRoot SP封闭剂单尖法根管充填可缩短根管填充时间,缓解患者疼痛,改善牙周指标。 展开更多
关键词 根管充填 iRoot SP封闭剂 单尖法 AH Plus封闭剂 牙周指标
下载PDF
上一页 1 2 19 下一页 到第
使用帮助 返回顶部