Simultaneous determination of impurity metal ions in high concentration zinc solution is very important for zinc hydrometallurgy,and the purpose is to establish a method for determining the trace Cu^2+,Cd^2+,Ni^2+and ...Simultaneous determination of impurity metal ions in high concentration zinc solution is very important for zinc hydrometallurgy,and the purpose is to establish a method for determining the trace Cu^2+,Cd^2+,Ni^2+and Co^2+in zinc electrolytes at the same time using the second derivative waves of single sweep oscillopolarography.Factors affecting the derivative waves of the ions were researched in a medium of dimethylglyoxime(DMG)-sodium citrate-sodium tetraborate.The results indicated that the interferences of a high concentration of Zn^2+and most other coexisting ions on the determination can be eliminated;when the Cu^2+,Cd^2+,Ni^2+and Co^2+are in the ranges of1×10^-7-3×10^-4,6×10^-7-2×10^-4,2×10^-8-1×10^-5and1×10^-8-3×10^-5mol/L,respectively,the relationships between the peak currents of the second derivative waves and the concentrations are linear;the detection limits to determine the Cu^2+,Cd^2+,Ni^2+and Co^2+are8×10^-8,2×10^-7,6×10^-9and4×10^-9mol/L,respectively.Without any sample pretreatment,the method was used to directly determine the trace Cu^2+,Cd^2+,Ni^2+and Co^2+in actual zinc electrolytes with satisfactory results.The method is simple,sensitive and rapid.展开更多
基金Projects (61533021,61773403) supported by the National Natural Science Foundation of China
文摘Simultaneous determination of impurity metal ions in high concentration zinc solution is very important for zinc hydrometallurgy,and the purpose is to establish a method for determining the trace Cu^2+,Cd^2+,Ni^2+and Co^2+in zinc electrolytes at the same time using the second derivative waves of single sweep oscillopolarography.Factors affecting the derivative waves of the ions were researched in a medium of dimethylglyoxime(DMG)-sodium citrate-sodium tetraborate.The results indicated that the interferences of a high concentration of Zn^2+and most other coexisting ions on the determination can be eliminated;when the Cu^2+,Cd^2+,Ni^2+and Co^2+are in the ranges of1×10^-7-3×10^-4,6×10^-7-2×10^-4,2×10^-8-1×10^-5and1×10^-8-3×10^-5mol/L,respectively,the relationships between the peak currents of the second derivative waves and the concentrations are linear;the detection limits to determine the Cu^2+,Cd^2+,Ni^2+and Co^2+are8×10^-8,2×10^-7,6×10^-9and4×10^-9mol/L,respectively.Without any sample pretreatment,the method was used to directly determine the trace Cu^2+,Cd^2+,Ni^2+and Co^2+in actual zinc electrolytes with satisfactory results.The method is simple,sensitive and rapid.