期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
求解不可压缩粘性流的GLS单元之比较 被引量:2
1
作者 魏泳涛 于建华 Philippe H.Geubelle 《四川大学学报(工程科学版)》 EI CAS CSCD 北大核心 2009年第1期60-67,共8页
比较了用于求解不可压缩粘性流的四边形双线性、双二次单元及三角形二次单元的性能,这些单元采用GLS稳定化有限元格式,而压力和速度采用等阶数插值。对得出的非线性有限元方程,使用Newton-Raphson迭代来求解,推导了计算切线矩阵的所需... 比较了用于求解不可压缩粘性流的四边形双线性、双二次单元及三角形二次单元的性能,这些单元采用GLS稳定化有限元格式,而压力和速度采用等阶数插值。对得出的非线性有限元方程,使用Newton-Raphson迭代来求解,推导了计算切线矩阵的所需公式。完成了对雷诺数分别为1000、5000、10000和20000的方腔上板流的数值模拟,并对不同单元的结果的精度和收敛率进行了比较。数值算例显示,较之于另两种单元,三角形的二次单元在精度和收敛性上达到最好的匹配。 展开更多
关键词 不可压缩粘性流 GLS稳定化有限元 Newton-Raphson迭代
下载PDF
A New Approach for Manufacturing a High Porosity Ti-6Al-4V Scaffolds for Biomedical Applications 被引量:4
2
作者 Montasser DEWIDAR H.Fouad MOHAMED Jae-Kyoo LIM 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2008年第6期931-935,共5页
Titanium and its alloys are currently considered as one of the most important metallic materials used in the biomedical applications, due to their excellent mechanical properties and superior biocompatibility. In the ... Titanium and its alloys are currently considered as one of the most important metallic materials used in the biomedical applications, due to their excellent mechanical properties and superior biocompatibility. In the present study, a new effective method for fabricating high porosity titanium alloy scaffolds was developed. Porous Ti-6Al-4V scaffolds are successfully fabricated with porosities ranging from 30% to 70% using spaceholder and powder sintering technique. Based on its acceptable properties, spherical carbamide particles with different diameters (0.56, 0.8, and 1mm) were used as the space-holder material in the present investigation. The Ti-6Al-4V scaffolds porosity is characterized by using scanning electron microscopy. The results show that the scaffolds spherical-shaped pores are depending on the shape, size and distribution of the space-holder particles. This investigation shows that the present new manufacturing technique is promising to fabricate a controlled high porosity and high purity Ti-6Al-4V scaffolds for hard tissue replacement. 展开更多
关键词 TI-6AL-4V Porous material Powder metallurgy Space-holder
下载PDF
复合材料损伤容限分析软件CDTAC1.0版简介
3
作者 刘峰 唐啸东 +2 位作者 陈普会 柴亚南 沈真 《计算力学学报》 CAS CSCD 北大核心 2001年第2期225-230,共6页
本文简要地介绍了由飞机强度研究所研制的复合材料损伤容限分析软件 CDTAC1.0版本的各项基本功能 ,及其所用的基本理论和程序结构 ,并给出了典型算例。
关键词 复合材料 冲击损伤 失效判据 剩余强度 飞机 分析软件 CDTAC 1.0版 损伤容限
下载PDF
New US device versus imaging US to assess tumor-in-brain
4
作者 Jacob Halevy-Politch Menashe Zaaroor +1 位作者 Alon Sinai Marius Constantinescu 《Chinese Neurosurgical Journal》 CSCD 2020年第4期211-223,共13页
Background:Applying ultrasonic imaging system during surgery requires the poring of saline,performing the measurement,and acquiring data from its display—which requires time and is highly“performer dependent,”i.e.,... Background:Applying ultrasonic imaging system during surgery requires the poring of saline,performing the measurement,and acquiring data from its display—which requires time and is highly“performer dependent,”i.e.,the measure is of a subjective nature.A new ultrasonic device was recently developed that overcomes most of these drawbacks and was successfully applied during tumor-in-brain neurosurgeries.The purpose of this study was to compare the two types of US devices and demonstrate their properties.Methods:The study was performed in the following stages:(i)an ex vivo experiment,where slices of the muscle and brain of a young porcine were laid one on top the other.Thicknesses and border depths were measured and compared,using the two types of US instruments.(ii)During human clinical neurosurgeries,tumor depth was compared by measuring it with both devices.(iii)Following the success of stages(i)and(ii),using solely the new US device,the tumor thickness was monitored while its resection.Correlation,Pearson’s coefficient,average,mean,and standard deviation were applied for statistical tests.Results:A high correlation was obtained for the distances of tissue borders and for their respective thicknesses.Applying these ultrasonic devices during neurosurgeries,tumor depths were monitored with high similarity(87%),which was also obtained by Pearson’s correlation coefficient(0.44).The new US device,thanks to its small footprint,its remote measurement,and the capability of monitoring intraoperatively and in real-time,provides the approach to tumor’s border before its complete resection.Conclusions:The new US device provides better accuracy than an ultrasonic imaging system;its data is objective;it enables to control the residual tumor thickness during its resection,and it is especially useful in restricted areas.These features were found of great help during a tumor-in-brain surgery and especially in the final stages of tumor’s resection. 展开更多
关键词 NEUROSURGERY TUMOR ULTRASOUND Pulse-echo Residual thickness
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部