BACKGROUND Owing to the advancement in bacterial identification techniques,the detection rate of non-tuberculous mycobacterium(NTM)has been on the rise.Different from Mycobacterium tuberculosis,the clinical symptoms o...BACKGROUND Owing to the advancement in bacterial identification techniques,the detection rate of non-tuberculous mycobacterium(NTM)has been on the rise.Different from Mycobacterium tuberculosis,the clinical symptoms of NTM are not easily detected,and the clinical efficacy and prognosis are somewhat heterogeneous.To report a case of Mycobacterium gordoniasis of cervical lymph node diagnosed in Anhui Chest Hospital in July 2022.CASE SUMMARY Upon examination,the patient who weighed 67.5 kg,was human immunodeficiency virus negative,healthy,without hypertension,diabetes,heart disease and other basic diseases microscopic analysis revealed granulomatous inflammation with coagulation necrosis in the lymphocyte,and tuberculosis was not ruled out.Plain computed tomography scans of the neck and chest indicated the presence of a single grayish-yellow and grayish-brown tissue,the dimensions of which was top of form 10.5 cm×3.0 cm×1.5 cm.After pathological consultation in our hospital,the diagnosis was confirmed as NTM infection.CONCLUSION This case report and the clinical epidemiological research on improving NTM have important guiding significance for improving decision-making in clinical treatments.展开更多
Objective To validate the performance of Mycob. T Stainer and Scanner(MTSS) for detecting acid-fast bacilli(AFB). Methods A total of 3,816 sputum samples from 1,515 tuberculosis(TB) suspects were tested at the Anhui P...Objective To validate the performance of Mycob. T Stainer and Scanner(MTSS) for detecting acid-fast bacilli(AFB). Methods A total of 3,816 sputum samples from 1,515 tuberculosis(TB) suspects were tested at the Anhui Provincial Chest Hospital and the Linyi People’s Hospital from April-August, 2016. Each specimen was placed on two smear slides. One slide was stained by the ziehl-neelsen(ZN) method to be read by conventional microscopy(CM). The other slide was stained and scanned by MTSS. All specimens were decontaminated with 4% NaO H, and then inoculated into solid culture. The performance of MTSS was assessed. Results MTSS produced higher average positivity rate(27.96%) as compared with the CM(26.83%). The overall sensitivity and specificity of MTSS were 78.9% and 93.9%, respectively. The sensitivity and specificity of CM was 77.4% and 95.0%, respectively. Conclusion MTSS exhibited a favorable performance in the detection of AFB. It may be an alternative to CM for screening TB.展开更多
文摘BACKGROUND Owing to the advancement in bacterial identification techniques,the detection rate of non-tuberculous mycobacterium(NTM)has been on the rise.Different from Mycobacterium tuberculosis,the clinical symptoms of NTM are not easily detected,and the clinical efficacy and prognosis are somewhat heterogeneous.To report a case of Mycobacterium gordoniasis of cervical lymph node diagnosed in Anhui Chest Hospital in July 2022.CASE SUMMARY Upon examination,the patient who weighed 67.5 kg,was human immunodeficiency virus negative,healthy,without hypertension,diabetes,heart disease and other basic diseases microscopic analysis revealed granulomatous inflammation with coagulation necrosis in the lymphocyte,and tuberculosis was not ruled out.Plain computed tomography scans of the neck and chest indicated the presence of a single grayish-yellow and grayish-brown tissue,the dimensions of which was top of form 10.5 cm×3.0 cm×1.5 cm.After pathological consultation in our hospital,the diagnosis was confirmed as NTM infection.CONCLUSION This case report and the clinical epidemiological research on improving NTM have important guiding significance for improving decision-making in clinical treatments.
基金supported by Chinese Anti-Tuberculosis Association[042016]
文摘Objective To validate the performance of Mycob. T Stainer and Scanner(MTSS) for detecting acid-fast bacilli(AFB). Methods A total of 3,816 sputum samples from 1,515 tuberculosis(TB) suspects were tested at the Anhui Provincial Chest Hospital and the Linyi People’s Hospital from April-August, 2016. Each specimen was placed on two smear slides. One slide was stained by the ziehl-neelsen(ZN) method to be read by conventional microscopy(CM). The other slide was stained and scanned by MTSS. All specimens were decontaminated with 4% NaO H, and then inoculated into solid culture. The performance of MTSS was assessed. Results MTSS produced higher average positivity rate(27.96%) as compared with the CM(26.83%). The overall sensitivity and specificity of MTSS were 78.9% and 93.9%, respectively. The sensitivity and specificity of CM was 77.4% and 95.0%, respectively. Conclusion MTSS exhibited a favorable performance in the detection of AFB. It may be an alternative to CM for screening TB.