期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Measurements,characteristics,and origin of new electromagnetic interference on magnetocardiographic measurements 被引量:1
1
作者 谷红芳 蔡文艳 +5 位作者 魏玉科 刘政豪 王倩 王越 戴远东 马平 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第4期185-192,共8页
In order to eliminate the influence of the large-amplitude magnetic field noise that has complicated magnetocardio- graphic studies since October 2009, we have performed high-accuracy measurement of the environmental ... In order to eliminate the influence of the large-amplitude magnetic field noise that has complicated magnetocardio- graphic studies since October 2009, we have performed high-accuracy measurement of the environmental magnetic field noise in the vicinity of Beijing Subway Line 4 using a three-component height Tc radio frequency (rf) superconducting quantum interference device (SQUID). By analysing the spatial form and other characteristics of the time and the fre- quency domains and by calculating the circumferential magnetic field distribution based on a duel-end feeding system model, we reach the following conclusions: (i) the main source of magnetic field noise is the magnetic field generated by thel subway trains, and (ii) the magnetic field interference results mainly from the imbalance between traction current and return rail current that is caused by the leakage current. 展开更多
关键词 electromagnetic interference leakage current subways MAGNETOCARDIOGRAPHY
下载PDF
A new magneto-cardiogram study using a vector model with a virtual heart and the boundary element method 被引量:1
2
作者 张琛 寿国法 +5 位作者 陆宏 华宁 唐雪正 夏灵 马平 唐发宽 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第9期348-352,共5页
A cardiac vector model is presented and verified, and then the forward problem for cardiac magnetic fields and electric potential are discussed based on this model and the realistic human torso volume conductor model,... A cardiac vector model is presented and verified, and then the forward problem for cardiac magnetic fields and electric potential are discussed based on this model and the realistic human torso volume conductor model, including lungs. A torso-cardiac vector model is used for a 12-lead electrocardiographic (ECG) and magneto-cardiogram (MCG) simulation study by using the boundary element method (BEM). Also, we obtain the MCG wave picture using a compound four-channel HTc.SQUID system in a magnetically shielded room. By comparing the simulated results and experimental results, we verify the cardiac vector model and then do a preliminary study of the forward problem of MCG and ECG. Therefore, the results show that the vector model is reasonable in cardiac electrophysiology. 展开更多
关键词 magneto-cardiogram cardiac vector model boundary element method realistic human torso
下载PDF
上一页 1 下一页 到第