Objective To examine the relationship between sex hormone–binding globulin (SHBG) and the metabolic syndrome (MetS) in pre-elderly and elderly men in China. Methods A cross-sectional studywas done among 437men, aged ...Objective To examine the relationship between sex hormone–binding globulin (SHBG) and the metabolic syndrome (MetS) in pre-elderly and elderly men in China. Methods A cross-sectional studywas done among 437men, aged 45 to 94 years old. Early morning fasting sera were assayed for total testosterone (TT), SHBG and other biochemical markers. Free testosterone (FT) was calculated. Results The SHBG level of the MetS group was significantly lower than those without MetS 35.70 (25.18, 47.10) nmol/L vs. 41.90 (31.80, 55.20) nmol/L; P < 0.001). As the number of MetS components increases, SHBG and TT levels became lower. SHBG correlated with age, as did TT and most of metabolic components. Body mass index (BMI), high density lipoprotein-cholesterol (HDL-C), triglyceride (TG), and TT remained independently associated with SHBG by multivariate regression analysis. In a logistic regression taking MetS as the dependent variable, SHBG (95% confidence interval (95% CI): 0.975��0.994, P = 0.018) and homeostasis model assessment for insulin resistance (HOMA-IR) (95%CI: 1.535��2.647, P < 0.001) were included in the final model. Conclusions Lower SHBG is independently associated with MetS among pre-elderly and elderly men. SHBG may be an independent predictor of MetS, but the mechanism of how SHBG is involved in MetS requires further studied.展开更多
This article aims to discuss strategies to operate Moflo XDP high-speed sorting equipment for cell sorting and optimize the instrument to run in the best operating state.Using fluorescent microspheres to quickly calib...This article aims to discuss strategies to operate Moflo XDP high-speed sorting equipment for cell sorting and optimize the instrument to run in the best operating state.Using fluorescent microspheres to quickly calibrate the position of the main liquid flow and the laser beam,adjust the amplitude and frequency according to different size CytoNozzles to find the best breakoff point,and adjust the four-way side flow to achieve the stable maintaining of the equipment,so as to quickly sort sample at high-speed.The absence of air bubbles in the sheath liquid barrel and the liquid path is the key to achieving a stable sorting-maintaining in the sorting process.The accurate calculation of the breakoff point and drop delay is the key to improve sorting efficiency and cell activity.展开更多
文摘Objective To examine the relationship between sex hormone–binding globulin (SHBG) and the metabolic syndrome (MetS) in pre-elderly and elderly men in China. Methods A cross-sectional studywas done among 437men, aged 45 to 94 years old. Early morning fasting sera were assayed for total testosterone (TT), SHBG and other biochemical markers. Free testosterone (FT) was calculated. Results The SHBG level of the MetS group was significantly lower than those without MetS 35.70 (25.18, 47.10) nmol/L vs. 41.90 (31.80, 55.20) nmol/L; P < 0.001). As the number of MetS components increases, SHBG and TT levels became lower. SHBG correlated with age, as did TT and most of metabolic components. Body mass index (BMI), high density lipoprotein-cholesterol (HDL-C), triglyceride (TG), and TT remained independently associated with SHBG by multivariate regression analysis. In a logistic regression taking MetS as the dependent variable, SHBG (95% confidence interval (95% CI): 0.975��0.994, P = 0.018) and homeostasis model assessment for insulin resistance (HOMA-IR) (95%CI: 1.535��2.647, P < 0.001) were included in the final model. Conclusions Lower SHBG is independently associated with MetS among pre-elderly and elderly men. SHBG may be an independent predictor of MetS, but the mechanism of how SHBG is involved in MetS requires further studied.
文摘This article aims to discuss strategies to operate Moflo XDP high-speed sorting equipment for cell sorting and optimize the instrument to run in the best operating state.Using fluorescent microspheres to quickly calibrate the position of the main liquid flow and the laser beam,adjust the amplitude and frequency according to different size CytoNozzles to find the best breakoff point,and adjust the four-way side flow to achieve the stable maintaining of the equipment,so as to quickly sort sample at high-speed.The absence of air bubbles in the sheath liquid barrel and the liquid path is the key to achieving a stable sorting-maintaining in the sorting process.The accurate calculation of the breakoff point and drop delay is the key to improve sorting efficiency and cell activity.