Performance Evaluation of Solar Chimney Draft: Application to Ventilation
1
作者 Boukaré Ouedraogo Adama Ouedraogo +2 位作者 Arouna Kabore Kalifa Palm Dieudonné Joseph Bahiebo 《Smart Grid and Renewable Energy》 2024年第4期107-122,共16页
Ventilation is one of the factors contributing to energy consumption in buildings and food preservation. The solar chimney proves to be an alternative for reducing conventional energy consumption. Thus, in this study,... Ventilation is one of the factors contributing to energy consumption in buildings and food preservation. The solar chimney proves to be an alternative for reducing conventional energy consumption. Thus, in this study, the performance of a solar chimney with two active faces for thermally drawing air from a chamber for preserving agri-food products was evaluated. These performances were experimentally assessed through data measurements: temperatures and velocities within the chimney, and their analysis using Excel and MATLAB. The obtained results were compared with those from literature to verify their validity. From this study, it is found that the maximum temperature at the chimney outlet reaches 49.4˚C with an average value of 43.7˚C. Additionally, the heating evolution of the chimney air presents four (04) identical phases in pairs, reflecting the chimney’s operation throughout day. The temperature difference between the outlet and inlet of the chimney reaches a maximum of 17˚C with an average of 12.6˚C. Regarding airflow, the maximum air velocity at the chimney outlet is 0.8 m/s, and the average velocities have consistently been greater than or equal to 0.46 m/s. Thus, it can be concluded that the solar chimney is capable of providing ventilation for the preservation chamber through thermal draft. 展开更多
关键词 Solar Chimney Natural Ventilation Thermal Draft AIRFLOW Chimney Effect
下载PDF
Analysis and Comparison of Doping Level Effects on a Crystalline Silicon PV Cell under Both Moderate Light Concentration and Normal Illumination Modes
2
作者 Mahamadi Savadogo Adama Ouedraogo +3 位作者 Boubacar Soro Zi Daouda Koudougou Martial Zoungrana Issa Zerbo 《Energy and Power Engineering》 CAS 2022年第10期523-540,共18页
The main purpose of this work is to study doping level effects on a silicon PV cell under both moderate light concentration and normal illumination. This study also aims to compare the doping level effects under the b... The main purpose of this work is to study doping level effects on a silicon PV cell under both moderate light concentration and normal illumination. This study also aims to compare the doping level effects under the both illumination modes. The results show for both illumination modes that diffusion parameters decrease with increasing doping level. These results are in agreement with the studies of the current and the voltage which showed for the two illumination modes that doping level increase leads to a decrease in current density and an increase in voltage. It also emerges for the two illumination modes and for the doping range 10<sup>13</sup> cm<sup>-3</sup> - 10<sup>16</sup> cm<sup>-3</sup>, a decrease of maximum power and conversion efficiency. The results also show that decrease of diffusion parameters is faster under moderate concentration in comparison with normal illumination. These results predict a greater variation rate of the current, the voltage, the maximum power and the conversion efficiency under moderate concentration compared to normal illumination. Contrary to diffusion parameters study, the results show higher variation rates of parameters under normal illumination. This is explained by the fact that under moderate concentration, carriers density is close to doping level: the cell is then in high injection condition. Consequently, under moderate concentration, carriers density is less sensitive to doping level variations. The study confirms that carriers density variation with the doping level is weak under the moderate concentration compared to normal illumination. 展开更多
关键词 Moderate Light Concentration Doping Level High Injection Diffusion Parameters Conversion Efficiency
下载PDF
Impact of the Thicknesses of the p and p+ Regions on the Electrical Parameters of a Bifacial PV Cell
3
作者 Ramatou Konate Bernard Zouma +3 位作者 Adama Ouedraogo Bruno Korgo Martial Zoungrana Sié Kam 《Energy and Power Engineering》 2022年第2期133-145,共13页
The present paper is about a contribution to the bifacial PV cell performances improvement. The PV cell efficiency is weak compared to the strong energy demand. In this study, the base thickness impacts and the p+<... The present paper is about a contribution to the bifacial PV cell performances improvement. The PV cell efficiency is weak compared to the strong energy demand. In this study, the base thickness impacts and the p+</sup> zone size influence are evaluated on the rear face of the polycrystalline back surface field bifacial silicon PV cell. The photocurrent density and photovoltage behaviors versus thickness of these regions are studied. From a three-dimensional grain of the polycrystalline bifacial PV cell, the magneto-transport and continuity equations of excess minority carriers are solved to find the expression of the density of excess minority carriers and the related electrical parameters, such as the photocurrent density, the photovoltage and the electric power for simultaneous illumination on both sides. The photocurrent density, the photovoltage and electric power versus junction dynamic velocity decrease for different thicknesses of base and the p+</sup> region increases for simultaneous illumination on both sides. It is found that the thickness of the p+</sup> region at 0.1 μm and the base size at 100 μm allow reaching the best bifacial PV cell performances. Consequently, it is imperative to consider the reduction in the thickness of the bifacial PV cell for exhibition of better performance. This reduced the costs and increase production speed while increasing conversion efficiency. 展开更多
关键词 Doped p+ Region Bifacial PV Cell Photocurrent Density PHOTOVOLTAGE Polycrystalline Solar Cell
下载PDF
Effect of the Orientation on the Comfort of a Building Made with Compressed Earth Block
4
作者 Fati Amadou Oumarou Adama Ouedraogo +6 位作者 Sikoudouin Maurice Thierry Ky Ramchandra Bhandari Amadou Konfe Ramatou Konate Rabani Adamou Dieudonné Joseph Bathiebo Sié Kam 《Smart Grid and Renewable Energy》 2021年第7期99-112,共14页
<span style="font-family:Verdana;">Thermal comfort is one of the most important requirements that scientists and building designers must meet to ensure the indoor air quality knowing its importance on ... <span style="font-family:Verdana;">Thermal comfort is one of the most important requirements that scientists and building designers must meet to ensure the indoor air quality knowing its importance on productivity and the health of occupants. However, it has never been of great concern for architects and architectural historians and seldom explores it. Buildings are the large consumer of the most energy consumption (around 40% worldwide) and generate around 35% of GHGs like CO</span><sub><span style="font-family:Verdana;">2</span></sub><span style="font-family:Verdana;"> that leads to extreme climate change. Hence, general and specific eco-friendly solutions in the field of building construction are required. Analysis of this study shows that air conditioning consumption can be significantly reduced thanks to the compressed earth bricks and by taking into account the climate and the orientation of the facades. However, this paper establishes viable low-cost option of building energy consumption while maintaining the thermal comfort and good indoor air quality. This work explains the effect of a single residential room orientation, by reducing </span><span style="font-family:Verdana;">the thermal amplitude, and improving the thermal phase shift in Ouagadougou</span><span style="font-family:Verdana;"> climate conditions in April. Internal temperature was modelled with 8 cardinal orientations. The result corresponds to a decrease of thermal amplitude </span><span style="font-family:Verdana;">damping greater than 4<span style="white-space:nowrap;">°</span>C between East-West and North-South sides and, with a thermal phase shift of 4</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">hours</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">30</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">minutes between the Nord and West walls.</span> 展开更多
关键词 Thermal Comfort Building Optimal Orientation Thermal Amplitude Thermal Phase Shift Energy Consumption Optimal Orientation
下载PDF
上一页 1 下一页 到第