期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Nonlinear vibration and buckling of circular sandwich plate under complex load 被引量:2
1
作者 杜国君 马建青 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2007年第8期1081-1091,共11页
The nonlinear vibration fundamental equation of circular sandwich plate under uniformed load and circumjacent load and the loosely clamped boundary condi- tion were established by von Karman plate theory, and then acc... The nonlinear vibration fundamental equation of circular sandwich plate under uniformed load and circumjacent load and the loosely clamped boundary condi- tion were established by von Karman plate theory, and then accordingly exact solution of static load and its numerical results were given. Based on time mode hypothesis and the variational method, the control equation of the space mode was derived, and then the amplitude frequency-load character relation of circular sandwich plate was obtained by the modified iteration method. Consequently the rule of the effect of the two kinds of load on the vibration character of the circular sandwich plate was investigated. When circumjacent load makes the lowest natural frequency zero, critical load is obtained. 展开更多
关键词 circular sandwich plate nonlinear vibration BUCKLING complex load amplitude frequency-load characteristic relation
下载PDF
Coupled Seepage and Heat Transfer Intake Model
2
作者 吴君华 由世俊 +1 位作者 张欢 李海山 《Transactions of Tianjin University》 EI CAS 2009年第6期446-451,共6页
In the beach well intake system, heat is transferred from soil to fluid when seawater is filtered through the aquifer, providing higher temperature source water to the seawater source heat pump (SWHP) system in winter... In the beach well intake system, heat is transferred from soil to fluid when seawater is filtered through the aquifer, providing higher temperature source water to the seawater source heat pump (SWHP) system in winter. A 3-D coupled seepage and heat transfer model for studying beach well intake system is established by adopting the computer code FLUENT. Numerical results of this model are compared with the experimental results under the same conditions. Based on the experiment-verified coupled model, numerical simulation of the supply water tem-perature is studied over a heating season. Results show that the minimum temperature of supply water is 275.2 K when this intake system continuously provides seawater with flow rate of 35 m3/h to SWHP. Results also indicate that the supply water temperature is higher than seawater, and that the minimum temperature of supply water lags behind seawater, ensuring effective and reliable operation of SWHP. 展开更多
关键词 传热模型 耦合渗流 供水温度 进气系统 流动海水 热量转移 水源热泵 数值结果
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部