Two active principles in traditional Chinese medicine Magnolia officinalis, magnolol and honokiol, were successfully separated by means of nonaqueous capillary electrophoresis. The effect of the composition of a nonaq...Two active principles in traditional Chinese medicine Magnolia officinalis, magnolol and honokiol, were successfully separated by means of nonaqueous capillary electrophoresis. The effect of the composition of a nonaqueous buffer on column efficiency and resolution, and the effect of acid additives on peak shapes were researched. The separation was conducted with a running buffer in a mixture of methanol/aeetonitrile/formamide ( volume ratio : 1 : 2 : 2 ), in which the concentrations of Tris, acetic acid, and water were 60 retool/L, 0. 04 mmol/L and 5% ( volume fration), respectively, and the pH^* (apperent pH) of the running buffer was 8.96. Magnolol and honokiol were separated on baseline within 20 min. The relative standard deviation of the analytes' concentrations in the sample is 1.32% for magnolol and 1.60% for honokiol, and the recoveries of the spiked sample are 98.4% for magnolol and 98. 0% for honokiol, respectively.展开更多
Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seve...Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seven polycyclic aromatic hydrocarbons(PAHs) in water. The novel SPME fiber exhibited higher extraction efficiency to PAHs compared with poly(dimethylsiloxane) and other calixarene-containing fibers. Extraction/retention mechanism based on the interactions between calixarenes and PAHs was discussed. Owing to the good selectivity and high extraction capability of this calixarene fiber, low detection limits were obtained in a range of 0.34―6.50 ng/L and the relative standard deviation values were ≤12.3% for all of the analytes. The linear ranges of the proposed method were five orders of magnitude for the tested compounds, with linear correlation coefficients(r) greater than 0.998. The method was applied to the determination of polycyclic aromatic hydrocarbons in nine water sources in Wuhan City, China. Standard addition method was selected for the quantification and the recovery values were in a satisfactory range. Total PAHs concentrations in the nine surface water samples were found to vary between undetectable and 8.840 μg/L with two- and three-ring PAHs predominating.展开更多
文摘Two active principles in traditional Chinese medicine Magnolia officinalis, magnolol and honokiol, were successfully separated by means of nonaqueous capillary electrophoresis. The effect of the composition of a nonaqueous buffer on column efficiency and resolution, and the effect of acid additives on peak shapes were researched. The separation was conducted with a running buffer in a mixture of methanol/aeetonitrile/formamide ( volume ratio : 1 : 2 : 2 ), in which the concentrations of Tris, acetic acid, and water were 60 retool/L, 0. 04 mmol/L and 5% ( volume fration), respectively, and the pH^* (apperent pH) of the running buffer was 8.96. Magnolol and honokiol were separated on baseline within 20 min. The relative standard deviation of the analytes' concentrations in the sample is 1.32% for magnolol and 1.60% for honokiol, and the recoveries of the spiked sample are 98.4% for magnolol and 98. 0% for honokiol, respectively.
基金Supported by the National Natural Science Foundation of China(No.30901007)the Fund of the Ministry of Education of China(No.081025)
文摘Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seven polycyclic aromatic hydrocarbons(PAHs) in water. The novel SPME fiber exhibited higher extraction efficiency to PAHs compared with poly(dimethylsiloxane) and other calixarene-containing fibers. Extraction/retention mechanism based on the interactions between calixarenes and PAHs was discussed. Owing to the good selectivity and high extraction capability of this calixarene fiber, low detection limits were obtained in a range of 0.34―6.50 ng/L and the relative standard deviation values were ≤12.3% for all of the analytes. The linear ranges of the proposed method were five orders of magnitude for the tested compounds, with linear correlation coefficients(r) greater than 0.998. The method was applied to the determination of polycyclic aromatic hydrocarbons in nine water sources in Wuhan City, China. Standard addition method was selected for the quantification and the recovery values were in a satisfactory range. Total PAHs concentrations in the nine surface water samples were found to vary between undetectable and 8.840 μg/L with two- and three-ring PAHs predominating.