Structured illumination microscopy(SIM)is suitable for biological samples because of its relatively low-peak illumination intensity requirement and high imaging speed.The system resolution is affected by two typical d...Structured illumination microscopy(SIM)is suitable for biological samples because of its relatively low-peak illumination intensity requirement and high imaging speed.The system resolution is affected by two typical detection modes:Point detection and area detection.However,a systematic analysis of the imaging performance of the different detection modes of the system has rarely been conducted.In this study,we compared laser point scanning point detection(PS-PD)and point scanning area detection(PS-AD)imaging in nonconfocal microscopy through theoretical analysis and simulated imaging.The results revealed that the imaging resolutions of PSPD and PS-AD depend on excitation and emission point spread functions(PSFs),respectively.Especially,we combined the second harmonic generation(SHG)of point detection(P-SHG)and area detection(A-SHG)with SIM to realize a nonlinear SIM-imaging technique that improves the imaging resolution.Moreover,we analytically and experimentally compared the nonlinear SIM performance of P-SHG with that of A-SHG.展开更多
基金supported by the National Natural Science Foundation of China (62275168,62275164,61905145)Guangdong Natural Science Foundation and Province Project (2021A1515011916)+1 种基金Shenzhen Science and Technology R&D and Innovation Foundation (JCYJ20200109105608771)the Science and Technology Planning Project of Shenzhen Municipality (ZDSYS20210623092006020).
文摘Structured illumination microscopy(SIM)is suitable for biological samples because of its relatively low-peak illumination intensity requirement and high imaging speed.The system resolution is affected by two typical detection modes:Point detection and area detection.However,a systematic analysis of the imaging performance of the different detection modes of the system has rarely been conducted.In this study,we compared laser point scanning point detection(PS-PD)and point scanning area detection(PS-AD)imaging in nonconfocal microscopy through theoretical analysis and simulated imaging.The results revealed that the imaging resolutions of PSPD and PS-AD depend on excitation and emission point spread functions(PSFs),respectively.Especially,we combined the second harmonic generation(SHG)of point detection(P-SHG)and area detection(A-SHG)with SIM to realize a nonlinear SIM-imaging technique that improves the imaging resolution.Moreover,we analytically and experimentally compared the nonlinear SIM performance of P-SHG with that of A-SHG.