This work presents the use of extended Modified Lambert Beer(MLB)model for accurate andcontinuous monitoring of percent blood carboxyhemoglobin(COHb)(SCO)and oxyhemoglobin(OxyHb)saturation(SO,)via a fitting procedure....This work presents the use of extended Modified Lambert Beer(MLB)model for accurate andcontinuous monitoring of percent blood carboxyhemoglobin(COHb)(SCO)and oxyhemoglobin(OxyHb)saturation(SO,)via a fitting procedure.This quantification technique is based on theabsorption characteristics of hemoglobin derivatives in the wavelength range of 520-600 nm togive the best estimates of the required parameters.A comparison of the performance of the developed model and MILB law is made using attenuation data from Monte Carlo simulations for a two-layered skin model.The results revealed a lower mean absolute error of 0.4%in the valuesestimated by the developed model as compared to 10%that is given by the MILB law.This studyshowed that the discussed approach is able to provide consistent and accurate measurement ofblood SO,and SCO across diferent skin pigmen tations suggesting that it may potentially be usedas an alternative means for clinical diagnosis of carbon monoxide(CO)poisoning.展开更多
A new auditory system model based on a combination of physiological and psycho-logical acoustic data has been proposed. This model consists of a bank of nonuniform bandpassfilters, detectors and main-frequency choosin...A new auditory system model based on a combination of physiological and psycho-logical acoustic data has been proposed. This model consists of a bank of nonuniform bandpassfilters, detectors and main-frequency choosing mechanisms, they act as basilar membranes, innerhair cells and nerve fibers, respectively. Combining with the improved critical bandwidth pa-rameters, the input to this model is analogous to the pressure at the eardrum, and the outputof this model simulates various features of the firing pattern. The synthesizer obtains the resul-tant speech by use of the simple adding method. Computer simulations show that the resultantspeech is highly intelligible and natural. The proposed model is correct and the improvement ofthe critical bandwidth parameters is effective.展开更多
文摘This work presents the use of extended Modified Lambert Beer(MLB)model for accurate andcontinuous monitoring of percent blood carboxyhemoglobin(COHb)(SCO)and oxyhemoglobin(OxyHb)saturation(SO,)via a fitting procedure.This quantification technique is based on theabsorption characteristics of hemoglobin derivatives in the wavelength range of 520-600 nm togive the best estimates of the required parameters.A comparison of the performance of the developed model and MILB law is made using attenuation data from Monte Carlo simulations for a two-layered skin model.The results revealed a lower mean absolute error of 0.4%in the valuesestimated by the developed model as compared to 10%that is given by the MILB law.This studyshowed that the discussed approach is able to provide consistent and accurate measurement ofblood SO,and SCO across diferent skin pigmen tations suggesting that it may potentially be usedas an alternative means for clinical diagnosis of carbon monoxide(CO)poisoning.
基金Partially supported by China National Science Foundation.
文摘A new auditory system model based on a combination of physiological and psycho-logical acoustic data has been proposed. This model consists of a bank of nonuniform bandpassfilters, detectors and main-frequency choosing mechanisms, they act as basilar membranes, innerhair cells and nerve fibers, respectively. Combining with the improved critical bandwidth pa-rameters, the input to this model is analogous to the pressure at the eardrum, and the outputof this model simulates various features of the firing pattern. The synthesizer obtains the resul-tant speech by use of the simple adding method. Computer simulations show that the resultantspeech is highly intelligible and natural. The proposed model is correct and the improvement ofthe critical bandwidth parameters is effective.