Nineteen Schlumberger vertical electrical soundings (VES) were carried out within and around Yenagoa city, South South Nigeria, using a maximum current electrode separation ranging between 300 - 400 m. The objectives ...Nineteen Schlumberger vertical electrical soundings (VES) were carried out within and around Yenagoa city, South South Nigeria, using a maximum current electrode separation ranging between 300 - 400 m. The objectives of the study were 1) to evaluate the possibility of mapping Quaternary sediments to infer the geological structure from the electrical interpretation and identify formations that may hold fresh water with low concentration of conducting minerals such as iron 2) to evaluate the vulnerability of the aquifer in the study area. The interpretation of the data collected was by computer assisted iterative interpretation using 1-D inversion technique software (1X1D, Interpex, USA). The results of the interpretation revealed four distinct geoelectric layers. Sounding curve types obtained in the area are mostly of the form ρ1 > ρ2 ρ3 ρ4 (where ρ is the density) but fresh water lenses with low concentration of conducting minerals such as iron were obtained only in locations that exhibit ρ1 > ρ2 ρ3 ρ4 curve types. Depth to the aquifer ranges from 4.5 m in the vicinity of VES 05 to 27.0 m at the vicinity of VES 14. The resistivity of the aquiferous horizon varies between 60 - 2868 Ωm. High transverse resistance values obtained were associated with zones of high transmissivity which agrees with the geology of the Benin Formation (Coastal Plain sands) consisting of fine-medium-coarse sands. The aquifer vulnerability map illustrates the impermeability of the overburden clay layer. Values of >0.5 mhos indicate good protective capacity, while values <0.3 mhos indicate vulnerable zones with probable risk of contamination.展开更多
The application of geophysical methods in combination with pumping tests provides a cost-effective and efficient alternative to estimate aquifer parameters. In this study, nineteen Schlumberger vertical electrical sou...The application of geophysical methods in combination with pumping tests provides a cost-effective and efficient alternative to estimate aquifer parameters. In this study, nineteen Schlumberger vertical electrical soundings (VES) were occupied in parts of Bayelsa State using a maximum current electrode separation ranging beweeen 300 - 400 m with the aim of estimating the transmissivity of the alluvial aquifer in areas where no pumping test has been carried out. Four of the soundings were carried out near existing boreholes in which pumping test had been carried out. The VES data obtained was interpreted, and layer parameters such as true resistivities and thickness were determined. The geoelectric parameters were used to generate the Dar Zarrouk parameters. Correlating the Dar Zarrouk parameter (e.g longitudinal unit conductance) with transmissivity derived from pumping test data, a constant was found which translate longitudinal unit conductance to transmissivity in a hydrogeological setting where effective porosity is the primary control on resistivity and hydraulic conductivity. Transmissivity determined from the pumping test data range between 1634.0 - 5292.0 m2/day while transmissivity values estimated from the longitudinal unit conductance (Lc) range between 721 - 8991 m2/day. The transmissivity estimated from the pumping test (Tp) data and transmissivity estimated from the longitudinal conductance (Lc) on comparison show excellent correlation (R2 = 0.92). The high transmissivity values agree with the geology of the Benin Formation (Coastal Plain sands) consisting of fine-medium-coarse sands. The results give a useful first approximation of the transmissivity and could be used to site exploratory boreholes.展开更多
Structural failure of buried cast/ductile iron water mains and tanks due to corrosion attacks manifests in leaks and is common in most cities throughout Nigeria. The appropriate corrective action, which aims to restor...Structural failure of buried cast/ductile iron water mains and tanks due to corrosion attacks manifests in leaks and is common in most cities throughout Nigeria. The appropriate corrective action, which aims to restore pipe/tank integrity is usually based on proper understanding of the degree of corrosiveness of the soil. In an attempt to determine the potential corrosiveness of the soil to buried metallic structures in Bayelsa State, surface geoelectrical sounding was carried out. Twenty-five Schlumberger Vertical Electrical Soundings (VES) was carried out in the freshwater and meander belt geomorphic zone and the salt water mangrove swamp and estuary complex of the state using a maximum current electrode separation ranging from 200 - 400 m. The data obtained was interpreted by computer iterative modeling using a 1D inversion technique software (1X1D, Interpex, USA). The results show a high degree of heterogeneity, both laterally and vertically, which is typical of a complex depositional environment. Generally, the sub-soil condition within the expected depth of installation of water mains and storage tanks (0 - 10 m) is slightly or moderately aggressive (effective aggressivity) in the freshwater and meander belt geomorphic zone but is very strongly aggressive in the salt water mangrove swamp and estuary complex. Corrosion cells which may lead to significant corrosion failures may occur in the vicinities of strongly aggressive stations. This poses a significant corrosion risk to metallic water pipes and storage tanks. Current day design should therefore either mandate the use of a non-metallic piping product (water mains) or cathodic protection system. Prediction of potential corrosiveness of a soil and thus the application of proper corrosion control measures will not only protect the environment from spillages but will also avert cost of repair, clean-up and replacement.展开更多
The corrosivity of the top three metres of the soil along a pipeline route was determined using soil electrical resistivity for the emplacement of a conduit intended to serve as a gas pipeline. Fifty-six Schlumberger ...The corrosivity of the top three metres of the soil along a pipeline route was determined using soil electrical resistivity for the emplacement of a conduit intended to serve as a gas pipeline. Fifty-six Schlumberger vertical electrical soundings (VES) were carried using a maximum current electrode separation ranging between 24 - 100 m at 2.0 km interval. The data was interpreted using a 1D inversion technique software (1X1D, Interpex, USA). Model resistivity values were classified in terms of the degree of corrosivity. Generally, the sub-soil condition along the pipeline route is non-aggressive but being slightly or moderately aggressive in certain areas due to local conditions prevailing at the measuring stations. Based on the corrosivity along the pipeline route, appropriate cathodic protection methods are prescribed.展开更多
文摘Nineteen Schlumberger vertical electrical soundings (VES) were carried out within and around Yenagoa city, South South Nigeria, using a maximum current electrode separation ranging between 300 - 400 m. The objectives of the study were 1) to evaluate the possibility of mapping Quaternary sediments to infer the geological structure from the electrical interpretation and identify formations that may hold fresh water with low concentration of conducting minerals such as iron 2) to evaluate the vulnerability of the aquifer in the study area. The interpretation of the data collected was by computer assisted iterative interpretation using 1-D inversion technique software (1X1D, Interpex, USA). The results of the interpretation revealed four distinct geoelectric layers. Sounding curve types obtained in the area are mostly of the form ρ1 > ρ2 ρ3 ρ4 (where ρ is the density) but fresh water lenses with low concentration of conducting minerals such as iron were obtained only in locations that exhibit ρ1 > ρ2 ρ3 ρ4 curve types. Depth to the aquifer ranges from 4.5 m in the vicinity of VES 05 to 27.0 m at the vicinity of VES 14. The resistivity of the aquiferous horizon varies between 60 - 2868 Ωm. High transverse resistance values obtained were associated with zones of high transmissivity which agrees with the geology of the Benin Formation (Coastal Plain sands) consisting of fine-medium-coarse sands. The aquifer vulnerability map illustrates the impermeability of the overburden clay layer. Values of >0.5 mhos indicate good protective capacity, while values <0.3 mhos indicate vulnerable zones with probable risk of contamination.
文摘The application of geophysical methods in combination with pumping tests provides a cost-effective and efficient alternative to estimate aquifer parameters. In this study, nineteen Schlumberger vertical electrical soundings (VES) were occupied in parts of Bayelsa State using a maximum current electrode separation ranging beweeen 300 - 400 m with the aim of estimating the transmissivity of the alluvial aquifer in areas where no pumping test has been carried out. Four of the soundings were carried out near existing boreholes in which pumping test had been carried out. The VES data obtained was interpreted, and layer parameters such as true resistivities and thickness were determined. The geoelectric parameters were used to generate the Dar Zarrouk parameters. Correlating the Dar Zarrouk parameter (e.g longitudinal unit conductance) with transmissivity derived from pumping test data, a constant was found which translate longitudinal unit conductance to transmissivity in a hydrogeological setting where effective porosity is the primary control on resistivity and hydraulic conductivity. Transmissivity determined from the pumping test data range between 1634.0 - 5292.0 m2/day while transmissivity values estimated from the longitudinal unit conductance (Lc) range between 721 - 8991 m2/day. The transmissivity estimated from the pumping test (Tp) data and transmissivity estimated from the longitudinal conductance (Lc) on comparison show excellent correlation (R2 = 0.92). The high transmissivity values agree with the geology of the Benin Formation (Coastal Plain sands) consisting of fine-medium-coarse sands. The results give a useful first approximation of the transmissivity and could be used to site exploratory boreholes.
文摘Structural failure of buried cast/ductile iron water mains and tanks due to corrosion attacks manifests in leaks and is common in most cities throughout Nigeria. The appropriate corrective action, which aims to restore pipe/tank integrity is usually based on proper understanding of the degree of corrosiveness of the soil. In an attempt to determine the potential corrosiveness of the soil to buried metallic structures in Bayelsa State, surface geoelectrical sounding was carried out. Twenty-five Schlumberger Vertical Electrical Soundings (VES) was carried out in the freshwater and meander belt geomorphic zone and the salt water mangrove swamp and estuary complex of the state using a maximum current electrode separation ranging from 200 - 400 m. The data obtained was interpreted by computer iterative modeling using a 1D inversion technique software (1X1D, Interpex, USA). The results show a high degree of heterogeneity, both laterally and vertically, which is typical of a complex depositional environment. Generally, the sub-soil condition within the expected depth of installation of water mains and storage tanks (0 - 10 m) is slightly or moderately aggressive (effective aggressivity) in the freshwater and meander belt geomorphic zone but is very strongly aggressive in the salt water mangrove swamp and estuary complex. Corrosion cells which may lead to significant corrosion failures may occur in the vicinities of strongly aggressive stations. This poses a significant corrosion risk to metallic water pipes and storage tanks. Current day design should therefore either mandate the use of a non-metallic piping product (water mains) or cathodic protection system. Prediction of potential corrosiveness of a soil and thus the application of proper corrosion control measures will not only protect the environment from spillages but will also avert cost of repair, clean-up and replacement.
文摘The corrosivity of the top three metres of the soil along a pipeline route was determined using soil electrical resistivity for the emplacement of a conduit intended to serve as a gas pipeline. Fifty-six Schlumberger vertical electrical soundings (VES) were carried using a maximum current electrode separation ranging between 24 - 100 m at 2.0 km interval. The data was interpreted using a 1D inversion technique software (1X1D, Interpex, USA). Model resistivity values were classified in terms of the degree of corrosivity. Generally, the sub-soil condition along the pipeline route is non-aggressive but being slightly or moderately aggressive in certain areas due to local conditions prevailing at the measuring stations. Based on the corrosivity along the pipeline route, appropriate cathodic protection methods are prescribed.