A Study of the TPS Based Beam-Matching Concept for Medical Linear Accelerators at a Tertiary Hospital
1
作者 Ntombela N. Lethukuthula Rovetto J. Nicolas +1 位作者 Nethwadzi C. Lutendo Mpumelelo Nyathi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2024年第1期16-25,共10页
The flexibility in radiotherapy can be improved if patients can be moved between any one of the department’s medical linear accelerators (LINACs) without the need to change anything in the patient’s treatment plan. ... The flexibility in radiotherapy can be improved if patients can be moved between any one of the department’s medical linear accelerators (LINACs) without the need to change anything in the patient’s treatment plan. For this to be possible, the dosimetric characteristics of the various accelerators must be the same, or nearly the same. The purpose of this work is to describe further and compare measurements and parameters after the initial vendor-recommended beam matching of the five LINACs. Deviations related to dose calculations and to beam matched accelerators may compromise treatment accuracy. The safest and most practical way to ensure that all accelerators are within clinical acceptable accuracy is to include TPS calculations in the LINACs matching evaluation. Treatment planning system (TPS) was used to create three photons plans with different field sizes 3 × 3 cm, 10 × 10 cm and 25 × 25 cm at a depth of 4.5 cm in Perspex. Calculated TPS plans were sent to Mosaiq to be delivered by five LINACs. TPS plans were compared with five LINACs measurements data using Gamma analyses of 2% and 2 mm. The results suggest that for four out of the five LINACs, there was generally good agreement, less than a 2% deviation between the planned dose distribution and the measured dose distribution. However, one specific LINAC named “Asterix” exhibited a deviation of 2.121% from the planned dose. The results show that all of the LINACs’ performance were within the acceptable deviation and delivering radiation dose consistently and accurately. 展开更多
关键词 RADIOTHERAPY Beam-Matching Linear Accelerator DOSIMETRY
下载PDF
Long-term outcomes after endoscopic removal of malignant colorectal polyps:Results from a 10-year cohort 被引量:1
2
作者 Anna Fábián Renáta Bor +13 位作者 Béla Vasas Mónika Szűcs Tibor Tóth Zsófia Bősze Kata Judit Szántó Péter Bacsur Anita Bálint Bernadett Farkas Klaudia Farkas Ágnes Milassin Mariann Rutka Tamás Resál Tamás Molnár Zoltán Szepes 《World Journal of Gastrointestinal Endoscopy》 2024年第4期193-205,共13页
BACKGROUND Choosing an optimal post-polypectomy management strategy of malignant colorectal polyps is challenging,and evidence regarding a surveillance-only strategy is limited.AIM To evaluate long-term outcomes after... BACKGROUND Choosing an optimal post-polypectomy management strategy of malignant colorectal polyps is challenging,and evidence regarding a surveillance-only strategy is limited.AIM To evaluate long-term outcomes after endoscopic removal of malignant colorectal polyps.METHODS A single-center retrospective cohort study was conducted to evaluate outcomes after endoscopic removal of malignant colorectal polyps between 2010 and 2020.Residual disease rate and nodal metastases after secondary surgery and local and distant recurrence rate for those with at least 1 year of follow-up were invest-igated.Event rates for categorical variables and means for continuous variables with 95%confidence intervals were calculated,and Fisher’s exact test and Mann-Whitney test were performed.Potential risk factors of adverse outcomes were RESULTS In total,135 lesions(mean size:22.1 mm;location:42%rectal)from 129 patients(mean age:67.7 years;56%male)were enrolled.The proportion of pedunculated and non-pedunculated lesions was similar,with en bloc resection in 82%and 47%of lesions,respectively.Tumor differentiation,distance from resection margins,depth of submucosal invasion,lymphovascular invasion,and budding were reported at 89.6%,45.2%,58.5%,31.9%,and 25.2%,respectively.Residual tumor was found in 10 patients,and nodal metastasis was found in 4 of 41 patients who underwent secondary surgical resection.Univariate analysis identified piecemeal resection as a risk factor for residual malignancy(odds ratio:1.74;P=0.042).At least 1 year of follow-up was available for 117 lesions from 111 patients(mean follow-up period:5.59 years).Overall,54%,30%,30%,11%,and 16%of patients presented at the 1-year,3-year,5-year,7-year,and 9-10-year surveillance examinations.Adverse outcomes occurred in 9.0%(local recurrence and dissemination in 4 patients and 9 patients,respectively),with no difference between patients undergoing secondary surgery and surveillance only.CONCLUSION Reporting of histological features and adherence to surveillance colonoscopy needs improvement.Long-term adverse outcome rates might be higher than previously reported,irrespective of whether secondary surgery was performed. 展开更多
关键词 Malignant colorectal polyps T1 tumor Endoscopic removal OUTCOMES Long-term SURVEILLANCE
下载PDF
Inter-Fraction Analysis of One Week Hypo-Fractionation of Deep Inspiration Breath Hold (DIBH) Technique for Left Sided Breast Cancer Radiation Treatment
3
作者 Ntombela N. Lethukuthula Mathuthu Manny Nyathi Mpumelelo 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2024年第3期41-52,共12页
The aim of this study was to investigate the inter-fraction variations, patient comfort and knowledge at Charlotte Maxeke Johannesburg Academic Hospital (CMJAH). The differences in set-up that occurred between treatme... The aim of this study was to investigate the inter-fraction variations, patient comfort and knowledge at Charlotte Maxeke Johannesburg Academic Hospital (CMJAH). The differences in set-up that occurred between treatment sessions for the left sided breast patients were observed and recorded. Measurements of routine set-up variation for 24 patients were performed by matching the cone beam computed tomography (CBCT) and the planning computed tomography (CT). Scans of all five fractions per patient were used to quantify the setup variations with standard deviation (SD) in all the three directions (anterior posterior, left right, and superior inferior). The patients DIBH comfort and knowledge was also evaluated. The average translational errors for the anterior posterior (AP, z), left-right (LR, x), and Superior-inferior (SI, y) directions were 0.40 cm, 0.40 cm, and 0.40 cm, respectively. The translation variation of the three directions showed statistical significance (P < 0.05). On comfort and knowledge investigation, among all participants, 80% moderately agreed that the therapist’s instructions for operating the deep inspiration breath hold (DIBH) technique were easy to understand, and 63.33% indicated that their comfort with the DIBH technique was neutral or average. The inter-fraction variations in patients with left-sided breast cancer were qualitatively analyzed. Significant shifts between CBCT and planning CT images were observed. The daily treatment verification could assist accurate dose delivery. 展开更多
关键词 Breast Cancer Deep Inspiration Breath Hold Hypo-Fractionation Inter-Fraction
下载PDF
Evaluation of Particle Properties of MgO/TiO2 Material by Monte Carlo Simulation Method
4
作者 Koffi N’guessan Placide Gabin Allangba Yves Kily Hervé Fagnidi +2 位作者 Hermann N’guessan Zié Traoré Koffi Arnaud Kamenan 《Journal of Materials Science and Chemical Engineering》 2024年第2期49-60,共12页
The simulation by the Monte Carlo method executed by the software PyPENELOPE proved effective to specify the particle propagation characteristics by calculating the absorption fractions, backscattering and transmissio... The simulation by the Monte Carlo method executed by the software PyPENELOPE proved effective to specify the particle propagation characteristics by calculating the absorption fractions, backscattering and transmission of electrons and secondary photons under the incidence of 0.5 to 20 KeV range of primary electrons. More than 99.9% of the primary electrons were transmitted in the 125 nm thick MgO/TiO<sub>2</sub> material at 20 KeV. This occurred because several interactions took place in the transmitted primary irradiation such as characteristic, fluorescence, and bremsstrahlung produced when of the occupation of the KL3, KL2, KM3, and KM2 shell and sub-shell of titanium and magnesium which are the elements with a high atomic number in the material. The transmission particle characteristic of this material is therefore an indicator capable of improving the electrical performance and properties of the sensor. 展开更多
关键词 Monte Carlo PyPENELOPE Primary Electrons Transmission MgO/TiO2
下载PDF
Patient dose from radiographic rejects/repeats in radiology centers of Urmia University of Medical Sciences, Iran
5
作者 Nasrollah Jabbari Ahad Zeinali Leili Rahmatnezhad 《Health》 2012年第2期94-100,共7页
Medical diagnostic X-rays are the largest manmade source of ionizing radiation received by the members of the general public. The aim of this study was to evaluate the radiographic reject/repeat rate and also to deter... Medical diagnostic X-rays are the largest manmade source of ionizing radiation received by the members of the general public. The aim of this study was to evaluate the radiographic reject/repeat rate and also to determine dose to the patients from radiographic rejects/repeats in radiology centers of Urmia University of Medical Sciences. During a 4 month period the most frequently examinations were chosen in three radiology centers. A form was designed as a reject/repeat analysis form for radiographers to complete each time a film was rejected by radiologists or repeated. The collected data were compiled at the end of each week and entered into a computer for analysis at the end of study. The results of this study showed that highest and lowest repetition rates were for pelvis, 14.01% and upper limb, 4.17%, respectively. The main reasons of repetition of radiographs were due to exposure (54%) and positioning (18%) errors. The average repeat rate in all three hospitals was 7.20%. It was found that human error has important role to repetition of radiographs. It is demonstrated that those patients having repeated radiographs received an average of 3.23 Gy·cm2. Based on the findings of this study it must be remembered that the highest repetition rate was for pelvis. Considering the radiosensitive organs related to pelvis especially in pediatric patients some special considerations must be applied for pelvis examinations. 展开更多
关键词 Patient Dose RADIOGRAPHY Exposure REPEAT Rate
下载PDF
Simulating Medical Imaging X-Ray Tubes with Various Parameters Using BEAMnrc Monte Carlo Software
6
作者 Nikolaos Chatzisavvas Thanasis Koustas +3 位作者 Georgios Karpetas Ioannis Valais Georgios Priniotakis Dimitrios Nikolopoulos 《Open Journal of Radiology》 2022年第3期125-141,共17页
Context: Medical imaging has a wide range of applications in today’s society. Basic projectional radiography, CT scans, mammograms and a range of other advanced technologies all use x-rays to create a large number of... Context: Medical imaging has a wide range of applications in today’s society. Basic projectional radiography, CT scans, mammograms and a range of other advanced technologies all use x-rays to create a large number of examinations every day across the world. The most essential component of such medical equipment is the x-ray tube, which creates and produces x-rays. Objective: We describe and investigate an abstract model-geometry of a simple x-ray tube utilizing the open-source software package of BEAMnrc of the EGSnrcmp family, which is well validated by several studies over the years, for high and low energy photons generation. Methodology: Our research focuses on two different electron beam energies: 120 keV and 30 keV. The 120 keV is the typical energy for simple projectional radiographic exams and CT examinations, whereas the 30 keV is the typical energy of mammography. Results: Two different anode materials are used for each case, Gold (Au) and Tungsten (W) for 120 keV because these are the most common in projectional radiography and CT;Molybdenum (Mo) and Rhodium (Rh) for 30 keV because with these targets most mammography exams are carried out. The aim of this work is to show how the BEAMnrc software package can simulate effectively x-ray generation of low-energy photons which are utilized in modern medical imaging procedures. We describe useful information on anode-target characteristics, such as anode angle, anode material, and metal filter materials, based on previous quality studies even by using software other than BEAMnrc. Conclusion: We demonstrate that BEAMnrc can be efficiently used for Monte Carlo modeling of low-energy photons. 展开更多
关键词 BREMSSTRAHLUNG FILTER Monte Carlo Spectral Distribution X-Ray Tube
下载PDF
Impact of random and scattered coincidences from outside of field of view on positron emission tomography/computed tomography imaging with different reconstruction protocols
7
作者 Mahak Osouli Alamdari Pardis Ghafarian +2 位作者 Arman Rahmim Mehrdad Bakhshayesh‑Karam Mohammad Reza Ay 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期40-52,共13页
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi... Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm. 展开更多
关键词 Positron emission tomography/computed tomography(PET/CT) Random coincidences Scatter coincidences·Time of flight(TOF) Point spread function(PSF) Field of view(FOV) Noise equivalent count rate(NECR) Signal-toNoise ratio(SNR)
下载PDF
Effect of Different Etching Time on Fabrication of an Optoelectronic Device Based on GaN/Psi
8
作者 Haneen D.Jabbar Makram A.Fakhri +4 位作者 Mohammed Jalal Abdul Razzaq Omar S.Dahham Evan T.Salim Forat H.Alsultany U.Hashim 《Journal of Renewable Materials》 SCIE EI 2023年第3期1101-1122,共22页
Gallium nitride(GaN)/porous silicon(PSi)film was prepared using a pulsed laser deposition method and 1064 nm Nd:YAG laser for optoelectronic applications and a series of Psi substrates were fabricated using a photoele... Gallium nitride(GaN)/porous silicon(PSi)film was prepared using a pulsed laser deposition method and 1064 nm Nd:YAG laser for optoelectronic applications and a series of Psi substrates were fabricated using a photoelectrochemical etching method assisted by laser at different etching times for 2.5–15 min at 2.5 min intervals.X-ray diffraction,room-temperature photoluminescence,atomic force microscopy and field emission scanning electron microscopy images,and electrical characteristics in the prepared GaN on the Psi film were investigated.The optimum Psi substrate was obtained under the following conditions:10 min,10 mA/cm^(2),and 24%hydrofluoric acid.The substrate exhibited two highly cubic crystalline structures at(200)and(400)orientations and yellow visible band photoluminescence,and homogeneous pores formed over the entire surface.The pores had steep oval shapes and were accompanied by small dark pores that appeared topographically and morphologically.The GaN/Psi film fabricated through PLD exhibited a high and hexagonal crystallographic texture in the(002)plane.Spectroscopic properties results revealed that the photoluminescence emission of the deposited nano-GaN films was in the ultraviolet band(374 nm)related to GaN material and in the near-infrared band(730 nm)related to the Psi substrate.The topographical and morphological results of the GaN films confirmed that the deposited film contained spherical grains with an average diameter of 51.8 nm and surface roughness of 4.8 nm.The GaN/Psi surface showed a cauliflower-like morphology,and the built-in voltage decreased from 3.4 to 2.7 eV after deposition.The fabricated GaN/Psi film exhibited good electrical characteristics. 展开更多
关键词 Gallium nitride porous silicon photoelectrochemical etching pulsed laser deposition optical device
下载PDF
Assessment of Monitor Units and Gamma Pass Rate for 6 MV and Flattening Filter Free (FFF) Beams in Volumetric Modulated Arc Therapy (VMAT)
9
作者 Kwame Anokye Amoabeng Anne Beate Langeland Marthinsen +4 位作者 Francis Hasford Samuel Nii Adu Tagoe Evelyn Anaafi Mark Pokoo-Aikins Theresa Bebaaku Dery 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2023年第1期1-8,共8页
Background: In linear accelerators, the treatment field’s uniform intensity is achieved by including a flattening filter in the beam. However, to produce more conformal dose distributions, contemporary radiotherapy p... Background: In linear accelerators, the treatment field’s uniform intensity is achieved by including a flattening filter in the beam. However, to produce more conformal dose distributions, contemporary radiotherapy practice now frequently uses fluence and aperture modifying techniques, such as volumetric modulated arc therapy. In these circumstances, the flattening filter in the beam manufacturing process is no longer required. It is therefore necessary to compare the monitor units of 6 MV and flattening filter free plans and how it influences the gamma pass rates to determine which is best for treating cervical cancer with pelvic lymph node metastasis. Methods: VMAT plans for fifteen patients with cervical cancer with pathological pelvic lymph node metastasis were included in this study. Each patient had two VMAT plans using conventional 6 MV beam with flattening filter and one with flattening filter free beam (FFF). The VMAT plans were made using two arcs, and then recalculated to give the planned dose distribution to the detectors in a Delta4 phantom. The VMAT plans were irradiated on the Delta4 phantom using an Elekta linear accelerator (6 MV). Results: The mean monitor unit for the 6 MV plans was 506.3 MU and a standard deviation of 48.6 while that of the FFF plans had a mean MU of 701.5 with a standard deviation of 87.6. The total monitor units (MUs) for the FFF plans were significantly greater than the 6 MV plans (p = 6.1 × 10<sup>-5</sup>). Conclusion: Flattening filter free (FFF) plans require more numbers of monitor units in comparison to conventional 6 MV filtered beams for external radiation of cervical cancer with pelvic lymph nodes involvement. 展开更多
关键词 Monitor Units Gamma Pass Rate Flattening Filter Free Multileaf Collimator
下载PDF
Correlation of Pathological Findings with MRI Imaging in Traumatic Spinal Cord Injury in Hyperacute Time Period in Non Human Primate Model
10
作者 Heather A. Simmons Kevin Johnson +6 位作者 Dane Schalk Kevin Brunner Puja Basu Casey Fitz Omar Fayez Saverio Capuano III Shanker Nesathurai 《Open Journal of Veterinary Medicine》 2023年第10期186-192,共7页
Traumatic Spinal Cord Injury (TSCI) remains a significant cause of human suffering. The World Health Organization estimates that there are between 250,000 to 500,000 new cases every year. Magnetic Resonance Imaging (M... Traumatic Spinal Cord Injury (TSCI) remains a significant cause of human suffering. The World Health Organization estimates that there are between 250,000 to 500,000 new cases every year. Magnetic Resonance Imaging (MRI) has been an important advancement in the diagnosis and management of TSCI. Nevertheless, there is a lack of literature correlating the radiological abnormalities and histopathological findings in the first hour (i.e., hyperacute period) after injury. The aim of this preliminary study is to elucidate the relationship between the MRI abnormalities and histopathological abnormalities in the hyperacute time period. In this study, a non-human primate model (NHP) primate model is used to characterize the histopathological and radiological features. Specifically, an experimental TSCI is created with an epidural catheter. This is followed by MRI imaging. The subject is then humanely euthanized and a post-mortem examination is completed. These results suggest that the noted radiological abnormalities are consistent with a combination of hemorrhage, edema as well as eosinophilic cellular matter in the central canal. 展开更多
关键词 Spinal Cord Injury PATHOLOGY MRI CORRELATION RADIOLOGY
下载PDF
Planning Target Volume Margin in Linac-Based Stereotactic Radiosurgery for Brain Metastases
11
作者 Hany S. Attallah Radwa M. Hamed +5 位作者 Khaled M. EL-Shahat Aliaa Mahmoud Mahmoud Abdallah Ibraheem Haggag Emad Moustafa Adel Yassin 《Journal of Cancer Therapy》 2024年第7期265-272,共8页
Background: The treatment of brain metastases with radiotherapy has shifted to the use of Stereotactic Radio-surgery (SRS). The technical issue of expanding the treatment volume around the Gross Tumor Volume (GTV) is ... Background: The treatment of brain metastases with radiotherapy has shifted to the use of Stereotactic Radio-surgery (SRS). The technical issue of expanding the treatment volume around the Gross Tumor Volume (GTV) is a current debate. Radiotherapy centers use variable GTV-PTV margins, ranging from one to 2 mm. Material and Methods: We performed a dosimetric comparison in plans of twenty patients using three margins: PTV zero, PTV1, and PTV2. We also developed imaginary Peel volumes. These volumes are described as follows: Peel1 = PTV1 − GTV, Peel2 = PTV2 − GTV. Results: Our results showed that the mean PTV volume differed significantly across the different margins (p = 0.000). The V12 of the brain significantly varied as a function of PTV margin (p = 0.000). The target coverage and plan quality indices were not significantly different. The Peel volume dosimetric analysis showed that the mean dose was significantly higher in the nearby normal brain tissue: Peel1 (p = 0.022) and Peel 2 (p = 0.013). Conclusion: According to our dosimetric analysis, expanding the GTV into a PTV by 1 mm margin is more convenient than 2 mm. 展开更多
关键词 SRS Brain Metastases PTV
下载PDF
Apparent diffusion coefficient values of normal testis and variations with age 被引量:8
12
作者 Athina C Tsili Dimitrios Giannakis +4 位作者 Anastasios Sylakos Alexandra Ntorkou Loukas G Astrakas Nikolaos Sofikitis Maria I Argyropoulou 《Asian Journal of Andrology》 SCIE CAS CSCD 2014年第3期493-497,共5页
The usefulness of diffusion-weighted magnetic resonance imaging (DWI) in the evaluation of scrotal pathology has recently been reported. A standard reference of normal testicular apparent diffusion coefficient (ADC... The usefulness of diffusion-weighted magnetic resonance imaging (DWI) in the evaluation of scrotal pathology has recently been reported. A standard reference of normal testicular apparent diffusion coefficient (ADC) values and their variations with age is necessary when interpreting normal testicular anatomy and pathology. We evaluated 147 normal testes using DWI, including 71 testes from 53 men aged 20-39years (group 1), 67 testes from 42 men aged 40-69 years (group 2) and nine testes from six men older than 70years (group 3). DWI was performed along the axial plane, using a single shot, multislice spin-echo planar diffusion pulse sequence and b-values of 0 and 900 s mm-2. The mean and standard deviation of the ADC values of normal testicular parenchyma were calculated for each age group separately. Analysis of variance (ANOVA) followed by post hoc analysis (Dunnett T3) was used for statistical purposes. The ADC values (x 10-3 mm2s-1) of normal testicular tissue were different among age groups (group 1:1.08 ± 0.13; group 2:1.15 ±0.15 and group 3:1.31± 0.22). ANOVA revealed differences in mean ADC among age groups (F= 11.391, P〈 0.001). Post hoc analysis showed differences between groups 1 and 2 (P= 0.008) and between groups 1 and 3 (P= 0.043), but not between groups 2 and 3 (P= 0.197). Our findings suggest that ADC values of normal testicular tissue increase with advancing age. 展开更多
关键词 age apparent diffusion coefficient (ADC) DIFFUSION-WEIGHTED magnetic resonance imaging TESTIS
下载PDF
Dynamic contrast-enhanced magnetic resonance imaging of prostate cancer: A review of current methods and applications 被引量:8
13
作者 Yousef Mazaheri Oguz Akin Hedvig Hricak 《World Journal of Radiology》 CAS 2017年第12期416-425,共10页
In many areas of oncology, dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) has proven to be a clinically useful, non-invasive functional imaging technique to quantify tumor vasculature and tumor perfusio... In many areas of oncology, dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) has proven to be a clinically useful, non-invasive functional imaging technique to quantify tumor vasculature and tumor perfusion characteristics. Tumor angiogenesis is an essential process for tumor growth, proliferation, and metastasis. Malignant lesions demonstrate rapid extravasation of contrast from the intravascular space to the capillary bed due to leaky capillaries associated with tumor neovascularity. DCE-MRI has the potential to provide information regarding blood flow, areas of hypoperfusion, and variations in endothelial permeability and microvessel density to aid treatment selection, enable frequent monitoring during treatment and assess response to targeted therapy following treatment. This review will discuss the current status of DCE-MRI in cancer imaging, with a focus on its use in imaging prostate malignancies as well as weaknesses that limit its widespread clinical use. The latest techniques for quantification of DCE-MRI parameters will be reviewed and compared. 展开更多
关键词 Prostate cancer Prostate magnetic resonance imaging Tumor angiogenesis Dynamic contrast-enhanced magnetic resonance imaging Kep = rate constant between extracellular extravascular space and plasma space Ktrans = volume transfer constant
下载PDF
Combined value of apparent diffusion coefficient-standardized uptake value max in evaluation of post-treated locally advanced rectal cancer 被引量:5
14
作者 Davide Ippolito Davide Fior +5 位作者 Chiara Trattenero Elena De Ponti Silvia Drago Luca Guerra Cammillo Talei Franzesi Sandro Sironi 《World Journal of Radiology》 CAS 2015年第12期509-520,共12页
AIM:To assess the clinical diagnostic value of functional imaging,combining quantitative parameters of apparent diffusion coefficient(ADC) and standardized uptake value(SUV)max,before and after chemo-radiation therapy... AIM:To assess the clinical diagnostic value of functional imaging,combining quantitative parameters of apparent diffusion coefficient(ADC) and standardized uptake value(SUV)max,before and after chemo-radiation therapy,in prediction of tumor response of patients with rectal cancer,related to tumor regression grade at histology.METHODS:A total of 31 patients with biopsy proven diagnosis of rectal carcinoma were enrolled in our study.All patients underwent a whole body ^(18)FDG positron emission tomography(PET)/computed tomography(CT) scan and a pelvic magnetic resonance(MR)examination including diffusion weighted(DW) imaging for staging(PET1,RM1) and after completion(6.6 wk)of neoadjuvant treatment(PET2,RM2).Subsequently all patients underwent total mesorectal excision and the histological results were compared with imaging findings.The MR scanning,performed on 1.5 T magnet(Philips,Achieva),included T2-weighted multiplanar imaging and in addition DW images with b-value of 0 and 1000 mm^2/s.On PET/CT the SUVmax of the rectal lesion were calculated in PET1 and PET2.The percentage decrease of SUVmax(△SUV) and ADC(△ADC) values from baseline to presurgical scan were assessed and correlated with pathologic response classified as tumor regression grade(Mandard's criteria;TRG1 = complete regression,TRG5 = no regression).RESULTS:After completion of therapy,all the patients were submitted to surgery.According to the Mandard's criteria,22 tumors showed complete(TRG1) or subtotal regression(TRG2) and were classified as responders;9tumors were classified as non responders(TRG3,4 and5).Considering all patients the mean values of SUVmax in PET 1 was higher than the mean value of SUVmax in PET 2(P < 0.001),whereas the mean ADC values was lower in RM1 than RM2(P < 0.001),with a △SUV and △ADC respectively of 60.2%and 66.8%.The best predictors for TRG response were SUV2(threshold of4.4) and ADC2(1.29 × 10^(-3) mm^2/s) with high sensitivity and specificity.Combining in a single analysis both the obtained median value,the positive predictive value,in predicting the different group category response in related to TRG system,presented R^2 of 0.95.CONCLUSION:The functional imaging combining ADC and SUVmax in a single analysis permits to detect changes in cellular tissue structures useful for the assessment of tumour response after the neoadjuvant therapy in rectal cancer,increasing the sensitivity in correct depiction of treatment response than either method alone. 展开更多
关键词 Advanced RECTAL cancer Functional IMAGING FDG-PET/CT Magnetic resonance IMAGING APPARENT diffusion coefficient NEOADJUVANT treatment Tumor regression grade
下载PDF
Virtual endoscopy of the urinary tract 被引量:4
15
作者 George C.Kagadis Dimitrios Siablis +2 位作者 Evangelos N.Liatsikos Theodore Petsas George C. Nikiforidis 《Asian Journal of Andrology》 SCIE CAS CSCD 2006年第1期31-38,共8页
Technological breakthroughs have advanced the temporal and spatial resolutions of diagnostic imaging, and 3 dimensional (3-D) reconstruction techniques have been introduced into everyday clinical practice. Virtual e... Technological breakthroughs have advanced the temporal and spatial resolutions of diagnostic imaging, and 3 dimensional (3-D) reconstruction techniques have been introduced into everyday clinical practice. Virtual endoscopy (VE) is a non-invasive technique that amplifies the perception of cross-sectional images in the 3-D space, providing precise spatial relationships of pathological regions and their surrounding structures. A variety of computer algorithms can be used to generate 3-D images, taking advantage of the information inherent in either spiral computed tomography or magnetic resonance imaging (MRI). VE images enable endoluminal navigation through hollow organs, thus simulating conventional endoscopy. Several clinical studies have validated the diagnostic utility of virtual cystoscopy, which has high sensitivity and specificity rates in the detection of bladder tumor. Published experience in the virtual exploration of the renal pelvis, ureter and urethra is encouraging but still scarce. VE is a safe, non-invasive method that could be applied in the long-term follow-up of patients with ureteropelvic junction obstruction, urinary bladder tumors and ureteral and/or urethral strictures. Its principal limitations are the inability to provide biopsy tissue specimens for histopathologic examination and the associated ionizing radiation hazards (unless MR/is used). However, in the case of endoluminal stenosis or obstruction, VE permits virtual endoluminal navigation both cephalad and caudal to the stenotic segment. To conclude, VE provides a less invasive method of evaluating the urinary tract, especially for clinicians who are less familiar with cross-sectional imaging than radiologists. (Asian J Androl 2006 Jan; 8: 31-38) 展开更多
关键词 computed tomography three-dimensional imaging virtual endoscopy urethral stricture
下载PDF
Optical and magnetic properties of porous anodic alumina films embedded with Co nanowires 被引量:4
16
作者 张敬晶 李子岳 +2 位作者 张惠敏 侯雪 孙会元 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第8期671-674,共4页
A simple method to tune the optical properties of porous anodic alumina (PAA) films embedded with Co nanowires (PAA@Co nanocomposite films) is reported in this paper. The films exhibit vivid structural colors and ... A simple method to tune the optical properties of porous anodic alumina (PAA) films embedded with Co nanowires (PAA@Co nanocomposite films) is reported in this paper. The films exhibit vivid structural colors and magnetic properties. The optical properties of the films can be effectively tuned by adjusting the thickness of the PAA template. The deposition of Co nanowires greatly increases the color saturation of the PAA films. The theoretical results of the changes in structural color according to the Bragg-Snell formula are consistent with the experimental results. PAA@Co films can be used in many areas, including decoration, display, and multifunctional anti-counterfeiting applications. 展开更多
关键词 NANOCOMPOSITES thin films optical and magnetic properties porous materials
下载PDF
Transcranial direct current stimulation for auditory verbal hallucinations:a systematic review of clinical trials 被引量:5
17
作者 Samaneh Rashidi Myles Jones +3 位作者 Eric Murillo-Rodriguez Sergio Machado Youguo Hao Ali Yadollahpour 《Neural Regeneration Research》 SCIE CAS CSCD 2021年第4期666-671,共6页
Transcranial direct current stimulation(tDCS)has been reportedly beneficial for different neurodegenerative disorders.tDCS has been reported as a potential adjunctive or alternative treatment for auditory verbal hallu... Transcranial direct current stimulation(tDCS)has been reportedly beneficial for different neurodegenerative disorders.tDCS has been reported as a potential adjunctive or alternative treatment for auditory verbal hallucination(AVH).This study aims to review the effects of tDCS on AVH in patients with schizophrenia through combining the evidence from randomized clinical trials(RCTs).The databases of PsycINFO(2000–2019),PubMed(2000–2019),EMBASE(2000–2019),CINAHL(2000–2019),Web of Science(2000–2019),and Scopus(2000–2019)were systematically searched.The clinical trials with RCT design were selected for final analysis.A total of nine RCTs were eligible and included in the review.Nine RCTs were included in the final analysis.Among them,six RCTs reported a significant reduction of AVH after repeated sessions of tDCS,whereas three RCTs did not show any advantage of active tDCS over sham tDCS.The current studies showed an overall decrease of approximately 28%of AVH after active tDCS and 10%after sham tDCS.The tDCS protocols targeting the sensorimotor frontal-parietal network showed greater treatment effects compared with the protocols targeting other regions.In this regard,cathodal tDCS over the left temporoparietal area showed inhibitory effects on AVHs.The most effective tDCS protocol on AVHs was twice-daily sessions(2 mA,20-minute duration)over 5 consecutive days(10 sessions)with the anode over the left dorsolateral prefrontal cortex and the cathode over the left temporal area.Some patient-specific and diseasespecific factors such as young age,nonsmoking status,and higher frequencies of AVHs seemed to be the predictors of treatment response.Taken together,the results of tDCS as an alternative treatment option for AVH show controversy among current literatures,since not all studies were positive.However,the studies targeting the same site of the brain showed that the tDCS could be a promising treatment option to reduce AVH.Further RCTs,with larger sample sizes,should be conducted to reach a conclusion on the efficacy of tDCS for AVH and to develop an effective therapeutic protocol for clinical setting. 展开更多
关键词 auditory verbal hallucinations dorsolateral prefrontal cortex effective protocol randomized clinical trial schizophrenia temporoparietal area transcranial direct current stimulation treatment efficacy
下载PDF
Visual Analysis of the Daily QA Results of Photon and Electron Beams of a Trilogy Linac over a Five-Year Period 被引量:6
18
作者 Maria F. Chan Qiongge Li +5 位作者 Xiaoli Tang Xiang Li Jingdong Li Grace Tang Margie A. Hunt Joseph O. Deasy 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第4期290-299,共10页
Data visualization technique was applied to analyze the daily QA results of photon and electron beams. Special attention was paid to any trend the beams might display. A Varian Trilogy Linac equipped with dual photon ... Data visualization technique was applied to analyze the daily QA results of photon and electron beams. Special attention was paid to any trend the beams might display. A Varian Trilogy Linac equipped with dual photon energies and five electron energies was commissioned in early 2010. Daily Linac QA tests including the output constancy, beam flatness and symmetry (radial and transverse directions) were performed with an ionization chamber array device (QA Beam Checker Plus, Standard Imaging). The data of five years were collected and analyzed. For each energy, the measured data were exported and processed for visual trending using an in-house Matlab program. These daily data were cross-correlated with the monthly QA and annual QA results, as well as the preventive maintenance records. Majority of the output were within 1% of variation, with a consistent positive/upward drift for all seven energies (^+0.25% per month). The baseline of daily device is reset annually right after the TG-51 calibration. This results in a sudden drop of the output. On the other hand, the large amount of data using the same baseline exhibits a sinusoidal behavior (period = 12 months;amplitude = 0.8%, 0.5% for photons, electrons, respectively) on symmetry and flatness when normalization of baselines is accounted for. The well known phenomenon of new Linac output drift was clearly displayed. This output drift was a result of the air leakage of the over-pressurized sealed monitor chambers for the specific vendor. Data visualization is a new trend in the era of big data in radiation oncology research. It allows the data to be displayed visually and therefore more intuitive. Based on the visual display from the past, the physicist might predict the trend of the Linac and take actions proactively. It also makes comparisons, alerts failures, and potentially identifies causalities. 展开更多
关键词 LINAC QA Data Visualization DAILY Output RADIOTHERAPY
下载PDF
Verification and Dosimetric Impact of Acuros XB Algorithm for Stereotactic Body Radiation Therapy (SBRT) and RapidArc Planning for Non-Small-Cell Lung Cancer (NSCLC) Patients 被引量:3
19
作者 Suresh Rana Kevin Rogers +2 位作者 Terry Lee Daniel Reed Christopher Biggs 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2013年第1期6-14,共9页
Purpose: The experimental verification of the Acuros XB (AXB) algorithm was conducted in a heterogeneous rectangular slab phantom, and compared to the Anisotropic Analytical Algorithm (AAA). The dosimetric impact of t... Purpose: The experimental verification of the Acuros XB (AXB) algorithm was conducted in a heterogeneous rectangular slab phantom, and compared to the Anisotropic Analytical Algorithm (AAA). The dosimetric impact of the AXB for stereotactic body radiation therapy (SBRT) and RapidArc planning for 16 non-small-cell lung cancer (NSCLC) patients was assessed due to the dose recalculation from the AAA to the AXB. Methods: The calculated central axis percentage depth doses (PDD) in a heterogeneous slab phantom for an open field size of 3 ×3 cm2 were compared against the PDD measured by an ionization chamber. For 16 NSCLC patients, the dose-volume parameters from the treatment plans calculated by the AXB and the AAA were compared using identical jaw settings, leaf positions, and monitor units (MUs). Results: The results from the heterogeneous slab phantom study showed that the AXB was more accurate than the AAA;however, the dose underestimation by the AXB (up to ?3.9%) and AAA (up to ?13.5%) was observed. For a planning target volume (PTV) in the NSCLC patients, in comparison to the AAA, the AXB predicted lower mean and minimum doses by average 0.3% and 4.3% respectively, but a higher maximum dose by average 2.3%. The averaged maximum doses to the heart and spinal cord predicted by the AXB were lower by 1.3% and 2.6% respectively;whereas the doses to the lungs predicted by the AXB were higher by up to 0.5% compared to the AAA. The percentage of ipsilateral lung volume receiving at least 20 and 5 Gy (V20 and V5 respectively) were higher in the AXB plans than in the AAA plans by average 1.1% and 2.8% respectively. The AXB plans produced higher target heterogeneity by average 4.5% and lower plan conformity by average 5.8% compared to the AAA plans. Using the AXB, the PTV coverage (95% of the PTV covered by the 100% of the prescribed dose) was reduced by average 8.2% than using the AAA. The AXB plans required about 2.3% increment in the number of MUs in order to achieve the same PTV coverage as in the AAA plans. Conclusion: The AXB is more accurate to use for the dose calculations in SBRT lung plans created with a RapidArc technique;however, one should also note the reduced PTV coverage due to the dose recalculation from the AAA to the AXB. 展开更多
关键词 Acuros XB AAA HETEROGENEITY Correction SBRT RAPIDARC LUNG Cancer
下载PDF
Chemical Analysis of Hydroxyapatite Artificial Bone Powders by Energy Dispersive X-Ray Fluorescence Spectrometry(EDXRF) 被引量:2
20
作者 O.K.Koksal G.Apaydin +4 位作者 E.Cengiz L.Samek I.H.Karahan A.Tozar M.Lankosz 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2018年第8期2645-2649,共5页
Stoichiometric hydroxyapatite(HA)nanoparticles were synthesized by a wet chemical method.Calcium nitrate tetra hydrate used as calcium source and dibasic ammonium phosphate used as phosphorous source.Calcium nitrate t... Stoichiometric hydroxyapatite(HA)nanoparticles were synthesized by a wet chemical method.Calcium nitrate tetra hydrate used as calcium source and dibasic ammonium phosphate used as phosphorous source.Calcium nitrate tetra hydrate and dibasic ammonium phosphate solutions were prepared by dissolving the salts in distilled water.Stoichiometric hydroxyapatite nanoparticles used by artificial bone powders and synthesized by a wet chemical method were analyzed using EDXRF method.The concentrations of K,Ca,Ti,V,Cr,Fe,Ni,Cu,Sr and Pb for artificial bone powders have been determined.Besides,Calcium contents were evaluated according to the agitation time and temperature in the production process. 展开更多
关键词 EDXRF X-ray Tube Elemental analysis HYDROXYAPATITE
下载PDF