期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Comparison of isolated-check visual evoked potential and standard automated perimetry in early glaucoma and high-risk ocular hypertension 被引量:4
1
作者 Xiang-Wu Chen Ying-Xi Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第4期599-604,共6页
AIM:To compare the diagnostic performance of isolatedcheck visual evoked potential(ic VEP) and standard automated perimetry(SAP),for evaluating the application values of ic VEP in the detection of early glaucoma.... AIM:To compare the diagnostic performance of isolatedcheck visual evoked potential(ic VEP) and standard automated perimetry(SAP),for evaluating the application values of ic VEP in the detection of early glaucoma.METHODS:Totally 144 subjects(288 eyes) were enrolled in this study.ic VEP testing was performed with the Neucodia visual electrophysiological diagnostic system.A 15% positive-contrast(bright) condition pattern was used in this device to differentiate between glaucoma patients and healthy control subjects.Signal-to-noise ratios(SNR) were derived based on a multivariate statistic.The eyes were judged as abnormal if the test yielded an SNR≤1.SAP testing was performed with the Humphrey Field Analyzer II.The visual fields were deemed as abnormality if the glaucoma hemifield test results outside normal limits;or the pattern standard deviation with P〈0.05;or the cluster of three or more non-edge points on the pattern deviation plot in a single hemifield with P〈0.05,one of which must have a P〈0.01.Disc photographs were graded as either glaucomatous optic neuropathy or normal by two experts who were masked to all other patient information.Moorfields regression analysis(MRA) used as a separate diagnostic classification was performed by Heidelberg retina tomograph(HRT).RESULTS:When the disc photograph grader was used as diagnostic standard,the sensitivity for SAP and ic VEP was 32.3% and 38.5% respectively and specificity was 82.3% and 77.8% respectively.When the MRA Classifier was used as the diagnostic standard,the sensitivity for SAP and ic VEP was 48.6% and 51.4% respectively and specificity was 84.1% and 78.0% respectively.When the combined structural assessment was used as the diagnostic standard,the sensitivity for SAP and ic VEP was 59.2%and 53.1% respectively and specificity was 84.2% and 84.6% respectivlely.There was no statistical significance between the sensitivity or specificity of SAP and ic VEP,regardless of which diagnostic standard was based on.CONCLUSION:The diagnostic performance of ic VEP is not better than that of SAP in the detection of early glaucoma. 展开更多
关键词 isolated-check visual evoked potential standard automated perimetry signal-to-noise ratios early glaucoma
下载PDF
Diabetes and risk of glaucoma:systematic review and a Meta-analysis of prospective cohort studies 被引量:5
2
作者 Ying-Xi Zhao Xiang-Wu Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第9期1430-1435,共6页
AIM:To quantify the association between diabetes and glaucoma using Meta-analysis.METHODS:Pub Med and Embase were searched using medical subject headings and key words related to diabetes and glaucoma.The inclusion ... AIM:To quantify the association between diabetes and glaucoma using Meta-analysis.METHODS:Pub Med and Embase were searched using medical subject headings and key words related to diabetes and glaucoma.The inclusion criteria were:1)the study design was a prospective cohort study;2)the exposure of interest was diabetes;3)the outcome of interest was primary open angle glaucoma(POAG);4)risk ratios(RR)and the corresponding 95%confidence interval(CI).Data were pooled using fixed effects models to take into account heterogeneity between studies.Seven prospective studies were selected.Diabetes increased the incidence of glaucoma by 36%(OR=1.36,95%CI=1.25-1.50).There was no evidence of statistical heterogeneity(I2=0,P=0.53)or publication bias(the funnel plot did not identify obvious asymmetry).RESULTS:Seven prospective cohort studies were incorporated in this Meta-analysis.The pooled RR of the association between POAG and diabetes based on the risk estimates of the seven cohort studies was 1.36(95%CI=1.24-1.50),with no significant heterogeneity across studies(I2=0;P=0.526).The sensitivity analysis yielded a range of RRs from 1.34(95%CI=1.22-1.48)to1.40(95%CI=1.18-1.67).CONCLUSION:Diabetes is associated with a significantly increased risk of glaucoma. 展开更多
关键词 primary open angle glaucoma DIABETES prospective studies
下载PDF
COVID-19 and the digestive system:A comprehensive review
3
作者 Ming-Ke Wang Hai-Yan Yue +6 位作者 Jin Cai Yu-Jia Zhai Jian-Hui Peng Ju-Fen Hui Deng-Yong Hou Wei-Peng Li Ji-Shun Yang 《World Journal of Clinical Cases》 SCIE 2021年第16期3796-3813,共18页
The coronavirus disease 2019(COVID-19)pandemic caused by severe acute respiratory syndrome coronavirus-2(SARS-CoV-2)is spreading at an alarming rate,and it has created an unprecedented health emergency threatening ten... The coronavirus disease 2019(COVID-19)pandemic caused by severe acute respiratory syndrome coronavirus-2(SARS-CoV-2)is spreading at an alarming rate,and it has created an unprecedented health emergency threatening tens of millions of people worldwide.Previous studies have indicated that SARS-CoV-2 ribonucleic acid could be detected in the feces of patients even after smearnegative respiratory samples.However,demonstration of confirmed fecal-oral transmission has been difficult.Clinical studies have shown an incidence rate of gastrointestinal(GI)symptoms ranging from 2%to 79.1%in patients with COVID-19.They may precede or accompany respiratory symptoms.The most common GI symptoms included nausea,diarrhea,and abdominal pain.In addition,some patients also had liver injury,pancreatic damage,and even acute mesenteric ischemia/thrombosis.Although the incidence rates reported in different centers were quite different,the digestive system was the clinical component of the COVID-19 section.Studies have shown that angiotensinconverting enzyme 2,the receptor of SARS-CoV-2,was not only expressed in the lungs,but also in the upper esophagus,small intestine,liver,and colon.The possible mechanism of GI symptoms in COVID-19 patients may include direct viral invasion into target cells,dysregulation of angiotensin-converting enzyme 2,immune-mediated tissue injury,and gut dysbiosis caused by microbiota.Additionally,numerous experiences,guidelines,recommendations,and position statements were published or released by different organizations and societies worldwide to optimize the management practice of outpatients,inpatients,and endoscopy in the era of COVID-19.In this review,based on our previous work and relevant literature,we mainly discuss potential fecal-oral transmission,GI manifestations,abdominal imaging findings,relevant pathophysiological mechanisms,and infection control and prevention measures in the time of COVID-19. 展开更多
关键词 COVID-19 SARS-CoV-2 Gastrointestinal manifestations Abdominal imaging MECHANISMS PREVENTION
下载PDF
Clinical efficacies of treating refractory insomnia patients with estazolam plus alternating current magnetic field 被引量:2
4
作者 WANG Zhi-zhong WANG Ya-ping +1 位作者 WAN Jun-ping WANG Jing 《Chinese Medical Journal》 SCIE CAS CSCD 2012年第17期3175-3176,共2页
As one of common physical and mental ailments, insomnia may cause serious adverse effects on a patient's daily life. And serious accidents occur in long-term cases.1 Despite comprehensive treatments, 9.38%-17.0% of... As one of common physical and mental ailments, insomnia may cause serious adverse effects on a patient's daily life. And serious accidents occur in long-term cases.1 Despite comprehensive treatments, 9.38%-17.0% of the treated insomniacs fail to benefit at all. Thus the term of "refractory insomnia" has been coined.24 At present, there is no literature reporting the roles of estazolam plus alternating current magnetic field (ACMF) for treating insomnia. In the present study, estazolam plus ACMF was employed for the patients with refractory insomnia so as to explore the clinical efficacies of such a combined modality. 展开更多
关键词 ESTAZOLAM alternating current magnetic field refractory insomnia Pittsburg sleep quality index
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部