期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Ex-PRESS implantation for different types of glaucoma 被引量:3
1
作者 Meltem Guzin Altinel Ayse Yagmur Kanra +1 位作者 Remzi Karadag Huseyin Bayramlar 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第8期1290-1297,共8页
AIM: To evaluate the clinical results, efficacy and safety of Ex-PRESS P200 glaucoma shunt implant in different types of medically uncontrolled glaucoma. METHODS: The study included 31 eyes of 31 patients that were un... AIM: To evaluate the clinical results, efficacy and safety of Ex-PRESS P200 glaucoma shunt implant in different types of medically uncontrolled glaucoma. METHODS: The study included 31 eyes of 31 patients that were unresponsive to medical antiglaucomatous therapy in whom Ex-PRESS P200 glaucoma shunt implantation was performed. The demographic characteristics of the patients, type of glaucoma, complete ocular examination results, number of antiglaucomatous drugs before and after surgery, early and late complications of surgery, additional surgical and nonsurgical medical interventions, and success rates were investigated from the patients’ files, retrospectively. RESULTS: The mean postoperative follow-up time was 16.4±7.5 mo. The preoperative mean corrected intraocular pressure(IOP) was 28.7±10.3 mm Hg and postoperative mean corrected IOP was 15.3±5.2 mm Hg(P<0.05) at the last visit. The mean IOP reduction was 39.9% when the preoperative and postoperative values of the last visits were compared. The average number of antiglaucomatous drug use decreased from 3.9±0.3 to 1.7±1.7 postoperatively(P<0.05). The use of antiglaucomatous medications at the last visit was more than in other studies in the literature. The most common complication was conjunctival leakage, which was seen in 7 patients. Other early complications were iris touch, intravitreal hemorrhage, hyphema, choroidal effusion, early transient hypotonia and corneal edema. One of the late complications was endophthalmitiswhich was seen in one case 6 mo after the operation, and the other late complication was opacification of the cornea in one patient. Twelve additional surgical operations associated to Ex-PRESS surgery and 3 bleb needling have done. At the last visit, the complete success rate was 32.3% and the qualified success rate was 77.5% in all patients. CONCLUSION: Ex-PRESS P200 glaucoma shunt implantation may be an effective procedure for medically uncontrolled glaucoma with significantly lower use of antiglaucomatous medications. 展开更多
关键词 GLAUCOMA Ex-PRESS IMPLANT GLAUCOMA SURGERY
下载PDF
The effects of implantable collamer lens implantation on higher order aberrations 被引量:1
2
作者 Belma Kayhan Efekan Coskunseven +1 位作者 Onurcan Sahin Ioannis Pallikaris 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第12期1848-1852,共5页
AIM: To evaluate the changes in higher order aberrations(HOAs) after implantable collamer lens(ICL;Staar Surgical, Nidau, Switzerland) implantation. METHODS: Totally 30 eyes of 18 patients with myopia were included in... AIM: To evaluate the changes in higher order aberrations(HOAs) after implantable collamer lens(ICL;Staar Surgical, Nidau, Switzerland) implantation. METHODS: Totally 30 eyes of 18 patients with myopia were included in this study with an average age of 25.77y(min: 21, max: 40). Refraction, uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), HOAs(entire, corneal and internal) were evaluated preoperatively and three months postoperatively. Ocular aberrations were measured by using iT race(Tracey Technology, Houston, Texas, USA). SPSS(IBM Corp. Released 2013. IBM SPSS Statistics for Windows, Version 22.0. Armonk, NY: IBM Corp) was used for the statistical analysis and the interpretation of the data. P values of less than 0.05 were considered statistically significant. RESULTS: The preoperative mean spherical power was -9.01 D(min:-5.00, max:-13.00) and the mean cylindrical error was -2.40 D(min:-0.50, max:-4.75). The postoperative mean residual spherical power was -0.73 D(min:-0.20, max:-1.75) and the mean cylindrical error was -0.89 D(min:-0.18, max:-2.09). Analyses were made on root mean square(RMS) values of total HOAs(tH OAs), spherical aberration, coma and trefoil as entire, corneal and internal components. The differences in entire t HOAs and in internal t HOAs were significant. There was no significant change found in spherical aberrations. The differences in entire coma and in internal coma were significant. There was no significant change found in corneal coma. With respect to trefoil, the only significant difference was in internal trefoil. CONCLUSION: The ICL implantation corrects the refractive error successfully and changes entire and internal HOAs of the eye. 展开更多
关键词 implantable collamer lens MYOPIA ABERRATIONS
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部