期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
多次雷电冲击对氧化锌避雷器阀片性能的影响(英文) 被引量:15
1
作者 Haryono T Sirait K T +1 位作者 Tumiran Hamzah Berahim 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2763-2771,共9页
A lightning arrester is used for electrical equipment protection against damage due to lightning strikes.One example of protected electrical equipment is electrical power transformer.If there is no lightning arrester ... A lightning arrester is used for electrical equipment protection against damage due to lightning strikes.One example of protected electrical equipment is electrical power transformer.If there is no lightning arrester installed to the transformer,when a lightning strike happens,it may receive a very high lightning overvoltage,which is certainly resulted in the transformer damage at its insulation.Usually,a lightning arrester specification data attached to a lightning arrester contains the rating data of the lightning arrester current and voltage.In the use of lightning arrester,the possibility of receiving multiple lightning strikes is not taken into account sometimes.In fact,in some places,the number of multiple strikes in short duration is quiet high in number.This condition makes the lightning arrester being stroked by multiple lightning strikes.Therefore,it may change the lightning arrester's properties,and then the arrester may not be able to provide good electrical equipment protection against lightning strike anymore.This condition will result in great loss to electrical companies and electrical consumers.Therefore,this research studied the effect of applying multiple lightning strikes to ZnO lightning arrester block.Every time a group of lightning impulse current is applied to the ZnO lightning arrester block,it is followed by the measuring of its 50 Hz voltage and current characteristic. The changing in the ZnO lightning arrester block 50 Hz characteristic then can be analyzed.It was found that by applying more numbers of lightning strikes which made the arrester becoming worse,even though,actually,the lightning impulse peak current was still under the rating of the lightning arrester current.In this case for a 5 kA,24 kV lightning arrester,even though the lightning impulse peak current flowing through the ZnO lightning arrester block was still 2500 A,the lightning arrester ZnO block had already been damaged.Having been damaged,an alternating current flowing through the damaged ZnO block was about 10000 times as much current flowing to the good one.The maximum of impulse energy absorbed by a ZnO block recorded was 334.7 J/cm^3.The damaged ZnO block should be replaced by a good one. 展开更多
关键词 follow current impulse current lightning arrester lightning strike multiple impulse current ZnO block
下载PDF
Gas concentration pre-warning system based on fuzzy structured element
2
作者 任志玲 于群 《Journal of Coal Science & Engineering(China)》 2008年第4期581-584,共4页
In order to accurately test gas concentration and effectively pre-warning when the gas concentration over-limited on work face,used the high-performance and low prices SCM and the low-cost and high transfer efficiency... In order to accurately test gas concentration and effectively pre-warning when the gas concentration over-limited on work face,used the high-performance and low prices SCM and the low-cost and high transfer efficiency bluetooth technology to forecast the gas concentration in real time.The data tested by SCM,then got the corresponding mathematical model of the data.Put forward the idea of using fuzzy structured element theory to dynamic forecast the gas concentration,analyzed the features in abnor- mal-effusing on work face and judge whether there was the possibility of abnormal gas-effusion.Simulation results show that mathematical model of this system about gas concentration is correct.This system changes coal mine monitoring system's traditional way of after-alarming into early-warning,and thus enhances its feasibility. 展开更多
关键词 矿井 瓦斯浓度 监测系统 传感器
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部