In this study, we will cover the basic methods used to distinguish between inrush current and fault current in power transformers. First, the nature of inrush current is presented compared to the fault current. Then t...In this study, we will cover the basic methods used to distinguish between inrush current and fault current in power transformers. First, the nature of inrush current is presented compared to the fault current. Then the nature of the magnetizing current due to energizing a power transformer at no-load is explained. The first generation of methods used to disable the protective relay system during inrush current, namely the Desensitizing and Tripping Suppressor, is introduced. The second generation, the harmonic restraint method and the waveform-based restraint method with their different versions, is explained. Then we will explore thoroughly the fictitious equivalent resistance method as an example of the third generation of model type restraining or blocking methods. Finally, a comparison between these methods and conclusion is carried out.展开更多
Fault restoration techniques have always been crucial for distribution system operators(DSOs).In the last decade,it started to gain more and more importance due to the introduction of output-based regulations where DS...Fault restoration techniques have always been crucial for distribution system operators(DSOs).In the last decade,it started to gain more and more importance due to the introduction of output-based regulations where DSO performances are evaluated according to frequency and duration of energy supply interruptions.The paper presents a tabu-searchbased algorithm able to assist distribution network operational engineers in identifying solutions to restore the energy supply after permanent faults.According to the network property,two objective functions are considered to optimize either reliability or resiliency.The mathematical formulation includes the traditional feeders,number of switching operation limit,and radiality constraints.Thanks to the DSO of Milan,Unareti,the proposed algorithm has been tested on a real distribution network to investigate its effectiveness.展开更多
文摘In this study, we will cover the basic methods used to distinguish between inrush current and fault current in power transformers. First, the nature of inrush current is presented compared to the fault current. Then the nature of the magnetizing current due to energizing a power transformer at no-load is explained. The first generation of methods used to disable the protective relay system during inrush current, namely the Desensitizing and Tripping Suppressor, is introduced. The second generation, the harmonic restraint method and the waveform-based restraint method with their different versions, is explained. Then we will explore thoroughly the fictitious equivalent resistance method as an example of the third generation of model type restraining or blocking methods. Finally, a comparison between these methods and conclusion is carried out.
文摘Fault restoration techniques have always been crucial for distribution system operators(DSOs).In the last decade,it started to gain more and more importance due to the introduction of output-based regulations where DSO performances are evaluated according to frequency and duration of energy supply interruptions.The paper presents a tabu-searchbased algorithm able to assist distribution network operational engineers in identifying solutions to restore the energy supply after permanent faults.According to the network property,two objective functions are considered to optimize either reliability or resiliency.The mathematical formulation includes the traditional feeders,number of switching operation limit,and radiality constraints.Thanks to the DSO of Milan,Unareti,the proposed algorithm has been tested on a real distribution network to investigate its effectiveness.