In the class of emerging high power electromagnetic sources, a complete pulsed power source, named MOUNA (French acronym of “Module Oscillant Utilisant une Nouvelle Architecture”) has been developed. This device mus...In the class of emerging high power electromagnetic sources, a complete pulsed power source, named MOUNA (French acronym of “Module Oscillant Utilisant une Nouvelle Architecture”) has been developed. This device must transmit waveforms with a wide frequency band and a high figure-of-merit. To improve the overall performance of the MOUNA system while maintaining its compact size, two approaches are being explored in the paper: the replacement of the dipole antenna by a helical antenna and its feeding signal influence. Helical antenna is cylindrical shape and relatively compact. It offers relatively good gain factor and directivity. The waveform delivered to the antenna is directly related to the amplitude of the radiated electric field. Therefore, different waveforms (step pulse, Gaussian pulse, bipolar pulse and damped sinusoid) are compared to point out the feed signal influence on the radiated electric field. Switch oscillators appear to be considered as interesting resonant sources for driving an antenna. The novel radiating source consists of a primary power source, a resonant transformer, a coaxial transmission line damped oscillator (also termed as coaxial resonator), and a helical antenna. This high voltage pulsed source is very compact (volume of only 2500 cc without the antenna). Our study aims at designing the antenna (number of turns, size…) and a coaxial damped oscillator directly implemented at the output of the transformer. A CST-based simulation is proposed to predict the performances of this wideband source.展开更多
Background: In the context of a nuclear reactor accident, thyroid is the main target organ of radioactive iodines. To avoid as much as possible thyroid disorders or even cancer development, it is recommended to admini...Background: In the context of a nuclear reactor accident, thyroid is the main target organ of radioactive iodines. To avoid as much as possible thyroid disorders or even cancer development, it is recommended to administer a single dose of potassium iodide to people at risk of exposure. Nevertheless, the Fukushima Dai-ichi disaster has pointed out many questions about the conditions of stable iodine prophylaxis implementation highlighting the need for reflection further revision of the actual “iodine doctrine”. Therefore, providing useful data is required notably through the implementation of animal experiments to strengthen current knowledge and to edit new recommendations. Methods: Urinary iodine constitutes a very good indicator to investigate the function of thyroid, its interpretation demands reliable analyses. Prior to perform animal experiments, two calibration methods were designed by our lab and compared together (standard addition and external calibration) to assess the urinary concentration of stable iodine in urine by ICP-MS. They were validated based on several key parameters especially linearity, accuracy and limits of detection (LOD) and quantification (LOQ). Results: The results were nicely satisfying. Indeed, both calibration methods have indicated very good coefficients of correlations, accuracies with low expanded relative uncertainties were obtained. The estimated LOD in the sample for standard addition method and external calibration were fully acceptable, 0.39 μg·L-1 and 0.35 μg·L-1, respectively. All performance criteria have been thus fulfilled successfully. The established methods were proven to be accurate, robust and sensitive. Once validated, both calibration methods were applied to rat urine samples and the results of z-score and Wilcoxon W test concluded that there were no statistically significant differences between both methods.展开更多
This study deals with a new evaluation method of nuclear electromagnetic pulse (NEMP) vulnerability on cots electronic equipments. The method consists in comparing electromagnetic compatibility (EMC) test severiti...This study deals with a new evaluation method of nuclear electromagnetic pulse (NEMP) vulnerability on cots electronic equipments. The method consists in comparing electromagnetic compatibility (EMC) test severities to NEMP conducted stresses. The comparison uses five characteristic criteria of the induced stresses, calculated with an analytic method. The process is based on a software named "SUSIE" (in French: SUSceptibilite a I'IEMN "Impulsion ElectroMagnttique d'origine Nucl6aire Haute Altitude"). Today, only conducted stresses are analyzed. An evolution is planned in 2013 to determine the equivalent vulnerability of radiated stresses and to validate the software.展开更多
文摘In the class of emerging high power electromagnetic sources, a complete pulsed power source, named MOUNA (French acronym of “Module Oscillant Utilisant une Nouvelle Architecture”) has been developed. This device must transmit waveforms with a wide frequency band and a high figure-of-merit. To improve the overall performance of the MOUNA system while maintaining its compact size, two approaches are being explored in the paper: the replacement of the dipole antenna by a helical antenna and its feeding signal influence. Helical antenna is cylindrical shape and relatively compact. It offers relatively good gain factor and directivity. The waveform delivered to the antenna is directly related to the amplitude of the radiated electric field. Therefore, different waveforms (step pulse, Gaussian pulse, bipolar pulse and damped sinusoid) are compared to point out the feed signal influence on the radiated electric field. Switch oscillators appear to be considered as interesting resonant sources for driving an antenna. The novel radiating source consists of a primary power source, a resonant transformer, a coaxial transmission line damped oscillator (also termed as coaxial resonator), and a helical antenna. This high voltage pulsed source is very compact (volume of only 2500 cc without the antenna). Our study aims at designing the antenna (number of turns, size…) and a coaxial damped oscillator directly implemented at the output of the transformer. A CST-based simulation is proposed to predict the performances of this wideband source.
基金partly supported by the French National“Investment for the future”funding programme.
文摘Background: In the context of a nuclear reactor accident, thyroid is the main target organ of radioactive iodines. To avoid as much as possible thyroid disorders or even cancer development, it is recommended to administer a single dose of potassium iodide to people at risk of exposure. Nevertheless, the Fukushima Dai-ichi disaster has pointed out many questions about the conditions of stable iodine prophylaxis implementation highlighting the need for reflection further revision of the actual “iodine doctrine”. Therefore, providing useful data is required notably through the implementation of animal experiments to strengthen current knowledge and to edit new recommendations. Methods: Urinary iodine constitutes a very good indicator to investigate the function of thyroid, its interpretation demands reliable analyses. Prior to perform animal experiments, two calibration methods were designed by our lab and compared together (standard addition and external calibration) to assess the urinary concentration of stable iodine in urine by ICP-MS. They were validated based on several key parameters especially linearity, accuracy and limits of detection (LOD) and quantification (LOQ). Results: The results were nicely satisfying. Indeed, both calibration methods have indicated very good coefficients of correlations, accuracies with low expanded relative uncertainties were obtained. The estimated LOD in the sample for standard addition method and external calibration were fully acceptable, 0.39 μg·L-1 and 0.35 μg·L-1, respectively. All performance criteria have been thus fulfilled successfully. The established methods were proven to be accurate, robust and sensitive. Once validated, both calibration methods were applied to rat urine samples and the results of z-score and Wilcoxon W test concluded that there were no statistically significant differences between both methods.
文摘This study deals with a new evaluation method of nuclear electromagnetic pulse (NEMP) vulnerability on cots electronic equipments. The method consists in comparing electromagnetic compatibility (EMC) test severities to NEMP conducted stresses. The comparison uses five characteristic criteria of the induced stresses, calculated with an analytic method. The process is based on a software named "SUSIE" (in French: SUSceptibilite a I'IEMN "Impulsion ElectroMagnttique d'origine Nucl6aire Haute Altitude"). Today, only conducted stresses are analyzed. An evolution is planned in 2013 to determine the equivalent vulnerability of radiated stresses and to validate the software.