An analytical solution for long waves propagating over a submerged atoll is established. The atolls involved in this study are annular coral reefs with large lagoons in the middle, and the expression of the cross sect...An analytical solution for long waves propagating over a submerged atoll is established. The atolls involved in this study are annular coral reefs with large lagoons in the middle, and the expression of the cross section is a trinomial function of the radial distance, i.e., h=ar(2s)-br~s+h_0, where s is the positive rational number. This analytical solution extends the theory by Wang et al.(2018) as s is no longer limited to s=2/m, where m is the positive integer. In addition, by adjusting the terrain parameters properly, the analytic solution can be degenerated to describe the wave propagation over topography with a hump or pit. According to the relationship between wave rays and wave energy, the distribution characteristics and formation mechanism of energy over the topography are expounded. When the lagoon is non-existent, all wave rays converge at the x-axis, which results in an abrupt amplification of the wave amplitude around the convergence point. When a lagoon is mounted on the top of the atoll, the rays are scattered due to the refraction of the lagoon, and only some rays converge at the symmetrical axis and the ridges on both sides,which results in the amplification of wave amplitudes in these areas.展开更多
A modified flux-coupling type superconducting fault current limiter(SFCL)is proposed here for suppressing fault currents.The modified SFCL consists of a coupling transformer,an yttrium barium copper oxide(YBCO)pancake...A modified flux-coupling type superconducting fault current limiter(SFCL)is proposed here for suppressing fault currents.The modified SFCL consists of a coupling transformer,an yttrium barium copper oxide(YBCO)pancake coil,and a controlled switch.By flexibly adjusting the controlled switch’s contact states based on the system operational conditions,the coupling transformer’s primary inductance as well as the YBCO coil’s normal-state resistance are incorporated into the main system for current limitation.Because the modified SFCL has the advantages of resistive and inductive SFCLs,it may improve the power system’s transient behavior.Hence,the SFCL’s effect on the transient stability of a multi-machine power system was also theoretically investigated.Further,simulations were conducted for accessing the SFCL’s performance characteristics under different fault conditions.The results show that using the proposed SFCL can effectively restrain the increased fault current and improve the bus voltage sag;meanwhile,the imitated multi-machine system’s power-angle oscillation can be obviously reduced.展开更多
基金financially supported by Hainan Provincial Natural Science Foundation of China (Grant No. 422MS090)Fujian Provincial Natural Scienceof China (Grant No. 2022J05282)2020 Xiamen Youth Innovation Fund Project of China (Grant No.3502Z20206069)。
文摘An analytical solution for long waves propagating over a submerged atoll is established. The atolls involved in this study are annular coral reefs with large lagoons in the middle, and the expression of the cross section is a trinomial function of the radial distance, i.e., h=ar(2s)-br~s+h_0, where s is the positive rational number. This analytical solution extends the theory by Wang et al.(2018) as s is no longer limited to s=2/m, where m is the positive integer. In addition, by adjusting the terrain parameters properly, the analytic solution can be degenerated to describe the wave propagation over topography with a hump or pit. According to the relationship between wave rays and wave energy, the distribution characteristics and formation mechanism of energy over the topography are expounded. When the lagoon is non-existent, all wave rays converge at the x-axis, which results in an abrupt amplification of the wave amplitude around the convergence point. When a lagoon is mounted on the top of the atoll, the rays are scattered due to the refraction of the lagoon, and only some rays converge at the symmetrical axis and the ridges on both sides,which results in the amplification of wave amplitudes in these areas.
基金Supported by the Fujian Young and Middle-Aged Teachers’Science and Technology Research Project(JAT201101).
文摘A modified flux-coupling type superconducting fault current limiter(SFCL)is proposed here for suppressing fault currents.The modified SFCL consists of a coupling transformer,an yttrium barium copper oxide(YBCO)pancake coil,and a controlled switch.By flexibly adjusting the controlled switch’s contact states based on the system operational conditions,the coupling transformer’s primary inductance as well as the YBCO coil’s normal-state resistance are incorporated into the main system for current limitation.Because the modified SFCL has the advantages of resistive and inductive SFCLs,it may improve the power system’s transient behavior.Hence,the SFCL’s effect on the transient stability of a multi-machine power system was also theoretically investigated.Further,simulations were conducted for accessing the SFCL’s performance characteristics under different fault conditions.The results show that using the proposed SFCL can effectively restrain the increased fault current and improve the bus voltage sag;meanwhile,the imitated multi-machine system’s power-angle oscillation can be obviously reduced.