Capacity Optimization Configuration of Hydrogen Production System for Offshore Surplus Wind Power
1
作者 Yanshan Lu Binbin He +6 位作者 Jun Jiang Ruixiao Lin Xinzhen Zhang Zaimin Yang Zhi Rao Wenchuan Meng Siyang Sun 《Energy Engineering》 EI 2023年第12期2803-2818,共16页
To solve the problem of residual wind power in offshore wind farms,a hydrogen production system with a reasonable capacity was configured to enhance the local load of wind farms and promote the local consumption of re... To solve the problem of residual wind power in offshore wind farms,a hydrogen production system with a reasonable capacity was configured to enhance the local load of wind farms and promote the local consumption of residual wind power.By studying the mathematical model of wind power output and calculating surplus wind power,as well as considering the hydrogen production/storage characteristics of the electrolyzer and hydrogen storage tank,an innovative capacity optimization allocation model was established.The objective of the model was to achieve the lowest total net present value over the entire life cycle.The model took into account the cost-benefit breakdown of equipment end-of-life cost,replacement cost,residual value gain,wind abandonment penalty,hydrogen transportation,and environmental value.The MATLAB-based platform invoked the CPLEX commercial solver to solve the model.Combined with the analysis of the annual average wind speed data from an offshore wind farm in Guangdong Province,the optimal capacity configuration results and the actual operation of the hydrogen production system were obtained.Under the calculation scenario,this hydrogen production system could consume 3,800 MWh of residual electricity from offshore wind power each year.It could achieve complete consumption of residual electricity from wind power without incurring the penalty cost of wind power.Additionally,it could produce 66,500 kg of green hydrogen from wind power,resulting in hydrogen sales revenue of 3.63 million RMB.It would also reduce pollutant emissions from coal-based hydrogen production by 1.5 tons and realize an environmental value of 4.83 million RMB.The annual net operating income exceeded 6 million RMB and the whole life cycle NPV income exceeded 50 million RMB.These results verified the feasibility and rationality of the established capacity optimization allocation model.The model could help advance power system planning and operation research and assist offshore wind farm operators in improving economic and environmental benefits. 展开更多
关键词 Surplus wind power offshore wind power hydrogen generation capacity optimization configuration total net present cost
下载PDF
A Compact UHF Antenna Based on Hilbert Fractal Elements and a Serpentine Arrangement for Detecting Partial Discharg
2
作者 Xiang Lin Jian Fang +4 位作者 Ming Zhang Kuang Yin Yan Tian Yingfei Guo Qianggang Wang 《Energy Engineering》 EI 2024年第5期1127-1141,共15页
Efforts to protect electric power systems from faults have commonly relied on the use of ultra-high frequency(UHF)antennas for detecting partial discharge(PD)as a common precursor to faults.However,the effectiveness o... Efforts to protect electric power systems from faults have commonly relied on the use of ultra-high frequency(UHF)antennas for detecting partial discharge(PD)as a common precursor to faults.However,the effectiveness of existing UHF antennas suffers from a number of challenges such as limited bandwidth,relatively large physical size,and low detection sensitivity.The present study addresses these issues by proposing a compact microstrip patch antenna with fixed dimensions of 100 mm×100 mm×1.6 mm.The results of computations yield an optimized antenna design consisting of 2nd-order Hilbert fractal units positioned within a four-layer serpentine arrangement with a fractal unit connection distance of 3.0 mm.Specifically,the optimized antenna design achieves a detection bandwidth for which the voltage standing wave ratio is less than 2 that is approximately 97.3%of the UHF frequency range(0.3–3 GHz).Finally,a prototype antenna is fabricated using standard printed circuit board technology,and the results of experiments demonstrate that the proposed antenna is capable of detecting PD signals at a distance of 8 m from the discharge source. 展开更多
关键词 Power system fault partial discharge UHF antenna fractal antenna micro-strip antenna
下载PDF
Carbon efficiency evaluation method for urban energy system with multiple energy complementary
3
作者 Xianan Jiao Jiekang Wu +1 位作者 Yunshou Mao Mengxuan Yan 《Global Energy Interconnection》 EI CSCD 2024年第2期142-154,共13页
Urban energy systems(UESs)play a pivotal role in the consumption of clean energy and the promotion of energy cascade utilization.In the context of the construction and operation strategy of UESs with multiple compleme... Urban energy systems(UESs)play a pivotal role in the consumption of clean energy and the promotion of energy cascade utilization.In the context of the construction and operation strategy of UESs with multiple complementary energy resources,a comprehensive assessment of the energy efficiency is of paramount importance.First,a multi-dimensional evaluation system with four primary indexes of energy utilization,environmental protection,system operation,and economic efficiency and 21 secondary indexes is constructed to comprehensively portray the UES.Considering that the evaluation system may contain a large number of indexes and that there is overlapping information among them,an energy efficiency evaluation method based on data processing,dimensionality reduction,integration of combined weights,and gray correlation analysis is proposed.This method can effectively reduce the number of calculations and improve the accuracy of energy efficiency assessments.Third,a demonstration project for a UES in China is presented.The energy efficiency of each scenario is assessed using six operational scenarios.The results show that Scenario 5,in which parks operate independently and investors build shared energy-storage equipment,has the best results and is best suited for green and low-carbon development.The results of the comparative assessment methods show that the proposed method provides a good energy efficiency assessment.This study provides a reference for the optimal planning,construction,and operation of UESs with multiple energy sources. 展开更多
关键词 Urban energy systems(UESs) Multiple energy complementary system Carbon efficiency evaluation Data downscaling Subjective and objective weight Gray correlation analysis
下载PDF
Correlation knowledge extraction based on data mining for distribution network planning
4
作者 Zhifang Zhu Zihan Lin +4 位作者 Liping Chen Hong Dong Yanna Gao Xinyi Liang Jiahao Deng 《Global Energy Interconnection》 EI CSCD 2023年第4期485-492,共8页
Traditional distribution network planning relies on the professional knowledge of planners,especially when analyzing the correlations between the problems existing in the network and the crucial influencing factors.Th... Traditional distribution network planning relies on the professional knowledge of planners,especially when analyzing the correlations between the problems existing in the network and the crucial influencing factors.The inherent laws reflected by the historical data of the distribution network are ignored,which affects the objectivity of the planning scheme.In this study,to improve the efficiency and accuracy of distribution network planning,the characteristics of distribution network data were extracted using a data-mining technique,and correlation knowledge of existing problems in the network was obtained.A data-mining model based on correlation rules was established.The inputs of the model were the electrical characteristic indices screened using the gray correlation method.The Apriori algorithm was used to extract correlation knowledge from the operational data of the distribution network and obtain strong correlation rules.Degree of promotion and chi-square tests were used to verify the rationality of the strong correlation rules of the model output.In this study,the correlation relationship between heavy load or overload problems of distribution network feeders in different regions and related characteristic indices was determined,and the confidence of the correlation rules was obtained.These results can provide an effective basis for the formulation of a distribution network planning scheme. 展开更多
关键词 Distribution network planning Data mining Apriori algorithm Gray correlation analysis Chi-square test
下载PDF
交直流混合输电线路空间电场分析(英文) 被引量:6
5
作者 李倩 刘俊翔 +1 位作者 李华 林福昌 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2866-2872,共7页
As the transmission line corridors become more and more rare in China,it is now inevitable for people to construct HVAC-HVDC hybrid transmission lines.The research on the electric field around the transmission lines p... As the transmission line corridors become more and more rare in China,it is now inevitable for people to construct HVAC-HVDC hybrid transmission lines.The research on the electric field around the transmission lines plays an important role in evaluating the electromagnetic environment nearby.However,few existing research now considered the mutual effect of HVAC-HVDC hybrid transmission lines.Thus,this research designed a program based on windows,which calculated the surface voltage gradient on the transmission lines and the electric field at ground level respectively.This research calculated the surface voltage gradient on the transmission lines by applying the improved method of successive images.For the electric field at ground level under AC transmission line,simulation charge method is used,while for the electric field at the ground level under DC transmission lines,deutsch assumption method is used.Comparing the results generated by the calculation with those in published literature,the program is reliable.Taking 500 kV transmission lines as an example,when considering the mutual effect of the HVAC-HVDC lines,the amplitude of the surface voltage gradient will increase by about 10%and the amplitude of the electric field at ground level will increase by about 8%,making the mutual effect of the AC and DC lines unneglectable. Larger part of the electric field at ground level under hybrid lines is produced by the DC line.Thus,in order to control the electric field at ground level under hybrid lines,it should pay more attention on that produced by the DC line. 展开更多
关键词 hybrid transmission lines method of successive images simulation charge method deutsch assumption method conductor surface gradient the ionized field
下载PDF
Fault diagnosis of electric transformers based on infrared image processing and semi-supervised learning 被引量:4
6
作者 Jian Fang Fan Yang +2 位作者 Rui Tong Qin Yu Xiaofeng Dai 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期596-607,共12页
It is crucial to maintain the safe and stable operation of distribution transformers,which constitute a key part of power systems.In the event of transformer failure,the fault type must be diagnosed in a timely and ac... It is crucial to maintain the safe and stable operation of distribution transformers,which constitute a key part of power systems.In the event of transformer failure,the fault type must be diagnosed in a timely and accurate manner.To this end,a transformer fault diagnosis method based on infrared image processing and semi-supervised learning is proposed herein.First,we perform feature extraction on the collected infrared-image data to extract temperature,texture,and shape features as the model reference vectors.Then,a generative adversarial network(GAN)is constructed to generate synthetic samples for the minority subset of labelled samples.The proposed method can learn information from unlabeled sample data,unlike conventional supervised learning methods.Subsequently,a semi-supervised graph model is trained on the entire dataset,i.e.,both labeled and unlabeled data.Finally,we test the proposed model on an actual dataset collected from a Chinese electricity provider.The experimental results show that the use of feature extraction,sample generation,and semi-supervised learning model can improve the accuracy of transformer fault classification.This verifies the effectiveness of the proposed method. 展开更多
关键词 TRANSFORMER Fault diagnosis Infrared image Generative adversarial network Semi-supervised learning
下载PDF
Building a Cloud-Based Energy Storage System through Digital Transformation of Distributed Backup Battery in Mobile Base Stations 被引量:10
7
作者 Song Ci Yanglin Zhou +2 位作者 Yuan Xu Xingjian Diao Junwei Wang 《China Communications》 SCIE CSCD 2020年第4期42-50,共9页
Battery energy storage systems(ESS) have been widely used in mobile base stations(BS) as the main backup power source. Due to the large number of base stations, massive distributed ESSs have largely stayed in idle and... Battery energy storage systems(ESS) have been widely used in mobile base stations(BS) as the main backup power source. Due to the large number of base stations, massive distributed ESSs have largely stayed in idle and very difficult to achieve high asset utilization. In recent years, the fast-paced development of digital energy storage(DES) technology has revolutionized the traditional operation and maintenance of ESSs by transforming them into digital assets, further enabling battery energy storage services, raising up a new way to achieve a much higher utilization of such kind of largely idle ESS resources. In this paper, the disruptive DES technology will be introduced and its application under the context of mobile BSs will be studied, and then a cloud-based energy storage(CES) platform is proposed based on a large scale distributed DESs to provide a new cyber-enabled energy storage service to the local utility company. A real-world case study shows the effectiveness and efficiency of the CES platform. 展开更多
关键词 digital ENERGY STORAGE dynamic RECONFIGURABLE BATTERY network ENERGY DIGITIZATION software-defined BATTERY system cloud ENERGY STORAGE
下载PDF
Space Charge Characteristics of Oil-paper Insulation with New Paper and Aged Oil 被引量:1
8
作者 MU Haibao WANG Da +4 位作者 WANG Shiqiang TIAN Jie LI Yuan WEI Yanhui ZHANG Guanjun 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1865-1872,共8页
Oil-paper compound insulation has been widely used in power transformers for quite a long time because of its good performances. The insulation gradually degrades under combined thermal, electrical and chemical stress... Oil-paper compound insulation has been widely used in power transformers for quite a long time because of its good performances. The insulation gradually degrades under combined thermal, electrical and chemical stresses during routine operations, mainly because of space charges inside. This work investigated the space charge characteristics in oil-paper insulation under oil aging circumstance. New trans- former oil samples are thermally aged to obtain different aging states, and their physical and chemical properties are analyzed. New Kraft papers are dried in vacuum and fully immersed in these different aged oil samples, and three kinds of oil-paper samples are obtained. We use the pulsed electro-acoustic (PEA) method to measure space charge under both DC voltage-on and voltage-off conditions at room temperature. The effect of oil aging state on characteristics of space charge injection, accumulation, and decay is analyzed and discussed. The results show that comparing with the DC voltage-off condition, more charges are injected into samples at the interface of electrode and dielectric when DC voltage is on. When the oil-aged state gets worse, more charges are induced at both cathode and anode, more space charges are accumulated in the bulk, the area of negative charges is larger, and local electric field is distorted more seriously. Moreover, for the voltage-off condition, aged oil is good for space charge decay, and trapped positive space charges decay faster than trapped negative charges. 展开更多
关键词 空间电荷 油纸绝缘 电荷特性 老年 老化状态 直流电压 衰减特性 电荷积累
下载PDF
Investigation of Atmospheric Pressure Dielectric Barrier Glow Discharge in Argon/Ammonia Mixture
9
作者 ZHANG Zenghui ZHANG Guanjun +2 位作者 SHAO Xianjun CHANG Zhengshi GU Chtmhui 《高电压技术》 EI CAS CSCD 北大核心 2013年第9期2254-2259,共6页
In this paper,the influence of ammonia admixture on argon discharge properties is investigated.Electrical measurements,as well as ten-nanoseconds-exposure photographs taken by an intensified charge-coupled device(ICCD... In this paper,the influence of ammonia admixture on argon discharge properties is investigated.Electrical measurements,as well as ten-nanoseconds-exposure photographs taken by an intensified charge-coupled device(ICCD)camera,are employed to confirm the existence of atmospheric pressure glow discharge(APGD)in Ar/NH3mixture.The breakdown voltage and transition voltage between APGD and filamentary discharge are studied at various ammonia concentrations.The results show that a small amount of NH3can lead to APGD due to the Penning ionization of NH3molecules by metastable argon,and the breakdown voltage increases with the growth in NH3concentrations owing to the electronegative feature of NH3.The optical emission spectrum of Ar/NH3APGD is analyzed.Besides,gas temperature is estimated at 327 K by the diagnoses of the OH(A-X)(0,0)band of the spectrum. 展开更多
关键词 大气压辉光放电 混合物 氩气 介质阻挡 APGD 常压 电荷耦合器件
下载PDF
Statistical Characteristics of Partial Discharge Caused by Typical Defects in Cable Joint under Oscillating Voltage
10
作者 Guangmao Li Zuwei Luo +2 位作者 Jun Xiong Zucheng Huang Yajun Wang 《Journal of Energy and Power Engineering》 2015年第3期310-316,共7页
关键词 局部放电信号 振荡电压 人工缺陷 电缆头 统计特征 无损检测方法 交联聚乙烯 交联电缆
下载PDF
Stochastic Accelerated Alternating Direction Method of Multipliers for Hedging Communication Noise in Combined Heat and Power Dispatch
11
作者 Zhigang Li Xinyu Liang +4 位作者 Fan Hu Wen Xiong Renbo Wu J.H.Zheng Q.H.Wu 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第2期696-706,共11页
Combined heat and power dispatch(CHPD)opens a new window for increasing operational flexibility and reducing wind power curtailment.Electric power and district heating systems are independently controlled by different... Combined heat and power dispatch(CHPD)opens a new window for increasing operational flexibility and reducing wind power curtailment.Electric power and district heating systems are independently controlled by different system operators;therefore,a decentralized solution paradigm is necessary for CHPD,in which only minor boundary information is required to be exchanged via a communication network.However,a nonideal communication environment with noise could lead to divergence or incorrect solutions of decentralized algorithms.To bridge this gap,this paper proposes a stochastic accelerated alternating direction method of multipliers(SA-ADMM)for hedging communication noise in CHPD.This algorithm provides a general framework to address more types of constraint sets and separable objective functions than the existing stochastic ADMM.Different from the single noise sources considered in the existing stochastic approximation methods,communication noise from multiple sources is addressed in both the local calculation and the variable update stages.Case studies of two test systems validate the effectiveness and robustness of the proposed SAADMM. 展开更多
关键词 Alternating direction method of multipliers combined heat and power dispatch communication noise decentralized optimization
原文传递
Analysis of conductance and interfacial polarisation behaviours of silicone rubber based on frequency domain spectroscopy
12
作者 Hao Hu Zhidong Jia +3 位作者 Xilin Wang Ruiyang Guan Weinan Fan Simin Luo 《High Voltage》 SCIE EI CSCD 2024年第1期56-65,共10页
Silicone rubber(SR)is widely used for cable insulation and operates in multi-stress coupling conditions.Its dielectric properties and ageing performance are the essential factors affecting cable operation.In this stud... Silicone rubber(SR)is widely used for cable insulation and operates in multi-stress coupling conditions.Its dielectric properties and ageing performance are the essential factors affecting cable operation.In this study,the frequency domain spectroscopy of unaged SR and SR aged under various conditions is measured.The dielectric responses before and after ageing are analysed in depth by the conjoint analysis via multiple complex planes(permittivity,conductivity,and modulus).Typical conductivity and interfacial polarisation properties,as well as property changes resulting from thermal and tensile ageing,are examined.Experimental results show that tensile ageing promotes conductance and interfacial polarisation,while thermal ageing shows the opposite effects.Based on the multi-core model and charge carrier hopping transport model,thermal and tensile ageing mechanisms on the conductance and interfacial polarisation behaviours of SR are demonstrated.Both behaviours exhibit positively correlated changing characteristics,suggesting that the two behaviours may originate from a common process.The carrier transport process,promoted by the tensile effect and slightly suppressed by the thermal effect,is the primary factor and considered an important indicator to evaluate the dielectric properties of SR insulation. 展开更多
关键词 INTERFACIAL RUBBER INSULATION
原文传递
Carbon emission impact on the operation of virtual power plant with combined heat and power system 被引量:5
13
作者 Yu-hang XIA Jun-yong LIU +1 位作者 Zheng-wen HUANG Xu ZHANG 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2016年第5期479-488,共10页
A virtual power plant(VPP) can realize the aggregation of distributed generation in a certain region, and represent distributed generation to participate in the power market of the main grid. With the expansion of VPP... A virtual power plant(VPP) can realize the aggregation of distributed generation in a certain region, and represent distributed generation to participate in the power market of the main grid. With the expansion of VPPs and ever-growing heat demand of consumers, managing the effect of fluctuations in the amount of available renewable resources on the operation of VPPs and maintaining an economical supply of electric power and heat energy to users have been important issues. This paper proposes the allocation of an electric boiler to realize wind power directly converted for supplying heat, which can not only overcome the limitation of heat output from a combined heat and power(CHP) unit, but also reduce carbon emissions from a VPP. After the electric boiler is considered in the VPP operation model of the combined heat and power system, a multi-objective model is built, which includes the costs of carbon emissions, total operation of the VPP and the electricity traded between the VPP and the main grid. The model is solved by the CPLEX package using the fuzzy membership function in Matlab, and a case study is presented. The power output of each unit in the case study is analyzed under four scenarios. The results show that after carbon emission is taken into account, the output of low carbon units is significantly increased, and the allocation of an electric boiler can facilitate the maximum absorption of renewable energy, which also reduces carbon emissions from the VPP. 展开更多
关键词 热电联产系统 碳排放 排放影响 运行 电厂 虚拟 模糊隶属度函数 分布式发电
原文传递
A Day-ahead Economic Dispatch Method Considering Extreme Scenarios Based on Wind Power Uncertainty 被引量:5
14
作者 Jian Xu Bao Wang +6 位作者 Yuanzhang Sun Qi Xu Ji Liu Huiqiu Cao Haiyan Jiang Ruobing Lei Mengjun Shen 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2019年第2期224-233,共10页
As the intermittency of wind power is a growing concern in the day-ahead economic dispatch,this paper proposes a day-ahead economic dispatch method considering extreme scenarios of wind power by using an uncertainty s... As the intermittency of wind power is a growing concern in the day-ahead economic dispatch,this paper proposes a day-ahead economic dispatch method considering extreme scenarios of wind power by using an uncertainty set.The uncertainty set inspired by robust optimization is used to describe wind power intermittency in this paper.Four extreme scenarios based on the uncertainty set are formulated to represent the worst cases of wind power fluctuation.An economic dispatch method considering the costs of both load shedding and wind curtailment is proposed.The economic dispatch model can be easily solved by a quadratic programming method owing to the introduction of four extreme scenarios and the uncertainty set of wind power.Simulation is done using the IEEE 30-bus system and the results verify the effectiveness of the proposed method. 展开更多
关键词 Economic dispatch extreme scenarios uncertainty set wind power
原文传递
The Averaged-value Model of a Flexible Power Electronics Based Substation in Hybrid AC/DC Distribution Systems 被引量:2
15
作者 Hong Liu Zhanfeng Deng +5 位作者 Xialin Li Li Guo Di Huang Shouqiang Fu Xiangyu Chen Chengshan Wang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2022年第2期452-464,共13页
The concept of a flexible power electronics substation(FPES)was first applied in the Zhangbei DC distribution network demonstration project.As a multi-port power electronics transformer(PET)with different AC and DC vo... The concept of a flexible power electronics substation(FPES)was first applied in the Zhangbei DC distribution network demonstration project.As a multi-port power electronics transformer(PET)with different AC and DC voltage levels,the FPES has adopted a novel topology integrating modular multilevel converter(MMC)and four-winding medium frequency transformer(FWMFT)based multiport DC-DC converter,which can significantly reduce capacitance in each sub-module(SM)of a MMC and also save space and cost.In this paper,in order to accelerate speed of electromagnetic transient(EMT)simulations of FPES based hybrid AC/DC distribution systems,an averaged-value model(AVM)is proposed for efficient and accurate representation of FPES.Assume that all SM capacitor voltages are perfectly balanced in the MMC,then the MMC behavior can be modeled using controlled voltage sources based on modulation voltages from control systems.In terms of the averaged current transfer characteristics among the windings of the FWMFT,we consider that all multiport DC-DC converters are controlled with the same dynamics,a lumped averaged model using controlled current and voltage sources has been developed for these four-port DC-DC converters connected to the upper or lower arms of the MMC.The presented FPES AVM model has been tested and validated by comparison with a detailed IGBT-based EMT model.Results show that the AVM is significantly more efficient while maintaining its accuracy in an EMT simulation. 展开更多
关键词 Averaged-value model(AVM) flexible power electronics substation(FPES) four-winding medium frequency transformer(FWMFT) hybrid AC/DC distribution systems modular multilevel converter(MMC) multiport DC-DC converter
原文传递
Decentralized State Estimation of Combined Heat and Power System Considering Communication Packet Loss 被引量:1
16
作者 Wenjian Zheng Zhigang Li +3 位作者 Xinyu Liang Jiehui Zheng Q.H.Wu Fan Hu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第4期646-656,共11页
In order to obtain an accurate state estimation of the operation in the combined heat and power system,it is necessary to carry out state estimation.Due to the limited information sharing among various energy systems,... In order to obtain an accurate state estimation of the operation in the combined heat and power system,it is necessary to carry out state estimation.Due to the limited information sharing among various energy systems,it is practical to perform state estimation in a decentralized manner.However,the possible communication packet loss is seldomly considered among various energy systems.This paper bridges this gap by proposing a relaxed alternating direction method of multiplier algorithm.It can also improve the computation efficiency compared with the conventional alternating direction of the multiplier algorithm.Case studies of two test systems are carried out to show the validity and superiority of the proposed algorithm. 展开更多
关键词 Alternating direction of multiplier algorithm combined heat and power system communication packet loss decentralized optimization state estimation
原文传递
Analysis of influence of a novel inductive fault current limiter on the circuit breaker in 500 kV power system
17
作者 Qiang Tang Shenli Jia +4 位作者 Yanzhe Zhang Shixin Xiu Wenxiong Mo Yong Wang Haibo Su 《High Voltage》 SCIE EI 2021年第6期997-1008,共12页
A contribution to the engineering application of a proposed 500 kV fault current limiter(FCL)is presented.A new type of FCL composed of a highly coupled split reactor(HCSR)and fast switches is proposed.When the circui... A contribution to the engineering application of a proposed 500 kV fault current limiter(FCL)is presented.A new type of FCL composed of a highly coupled split reactor(HCSR)and fast switches is proposed.When the circuit breaker(CB)in series with the FCL in the 500 kV power system interrupts the limited fault current,the rate of rise of the recovery voltage(RRRV)reaches a value much higher than the rated value.Based on a simplified equivalent single‐phase circuit,the influence of the new FCL on the interruption procedure of the CB is simulated and discussed.The simulation results show that the high RRRV is caused by high‐frequency resonant oscillations between the HCSR and its parasite capacitance.Analysis indicates that when the reactance of the FCL is close to the short circuit reactance of the system,the RRRV will reach the highest value.To solve this issue,we proposed installing a shunt capacitor with the FCL.Simulation results showed that the RRRVunder all fault modes could be restrained to below the rated value by introducing a certain shunt capacitor. 展开更多
关键词 FAULT INDUCTIVE POWER
原文传递
Identification Method for Single-line-to-ground Faults with Line Break Based on Phasor Measurement in Distribution Networks 被引量:1
18
作者 Yadong Liu Zichang Li +4 位作者 Yingjie Yan Guanghui He Jian Fang Kejun Li Xiuchen Jiang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第3期907-916,共10页
The single-line-to-ground faults with line breaks(SLGFs-LBs)occur more and more frequently in distribution networks and can cause major safety accidents.It is difficult to distinguish the single-line-to-ground faults(... The single-line-to-ground faults with line breaks(SLGFs-LBs)occur more and more frequently in distribution networks and can cause major safety accidents.It is difficult to distinguish the single-line-to-ground faults(SLGFs)in resonant grounding systems and ungrounding systems due to the same electrical characteristics on the source side and uncertain operation conditions of distribution networks.This paper proposes a method for distinguishing SLGFs-LBs and SLGFs.First,the source-side and load-side voltage characteristics of SLGFs and SLGFs-LBs are analyzed,and the phase difference between the voltages of the fault phase and non-fault phase on the load side is selected as the identification criterion.Phasor measurement units(PMUs)are selected as measuring devices.Then,the effects of operation conditions and external devices in distribution networks on the proposed method are discussed,and the phase errors caused by them are calculated to correct the identification method.Finally,the field testing and simulation experiments are conducted to verify the effectiveness and robustness of the proposed method. 展开更多
关键词 Distribution network phase measurement unit single-line-to-ground fault(SLGF) identification method influencing factor
原文传递
Risk Management of Weather-related Failures in Distribution Systems Based on Interpretable Extra-trees
19
作者 Ying Du Yadong Liu +2 位作者 Yingjie Yan Jian Fang Xiuchen Jiang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第6期1868-1877,共10页
Weather-related failures significantly challenge the reliability of distribution systems. To enhance the risk management of weather-related failures, an interpretable extra-trees based weather-related risk prediction ... Weather-related failures significantly challenge the reliability of distribution systems. To enhance the risk management of weather-related failures, an interpretable extra-trees based weather-related risk prediction model is proposed in this study. In the proposed model, the interpretability is successfully introduced to extra-trees by analyzing and processing the paths of decision trees in extra-trees. As a result, the interpretability of the proposed model is reflected in the following three respects: it can output the importance, contribution, and threshold of weather variables at high risk. The importance of weather variables can help in developing a long-term risk prevention plan. The contribution of weather variables provides targeted operation and maintenance advice for the next prediction period. The threshold of weather variables at high risk is critical in further preventing high risks. Compared with the black-box machine learning risk prediction models, the proposed model overcomes the application limitations. In addition to generating predicted risk levels, it can also provide more guidance information for the risk management of weather-related failures. 展开更多
关键词 Extra-tree machine learning INTERPRETABILITY weather-related failure distribution system
原文传递
Interruption Characteristics of High-speed Switches in 500 kV Fault Current Limiter with High Coupled Split Reactance
20
作者 Yanzhe Zhang Shixin Xiu +5 位作者 Qiang Tang Shenli Jia Bo Chu Wenxiong Mo Yong Wang Haibo Su 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第4期1577-1584,共8页
A 500 kV high-voltage AC fault current limiter(FCL)based on a high coupled split reactor(HCSR)is pro-posed by the National key R&D project team.Low impedance under normal conditions and high impedance under short-... A 500 kV high-voltage AC fault current limiter(FCL)based on a high coupled split reactor(HCSR)is pro-posed by the National key R&D project team.Low impedance under normal conditions and high impedance under short-circuit conditions are accomplished by the cooperation of HCSR and high-speed switches.High-speed switches play an important role in current limiting processes,thus interruption characteristics of the high-speed switch in the 500 kV FCL are studied in this paper.The simulation model of the FCL and the external equivalent power grid are established.The short-circuit current and recovery voltage characteristics of the high-speed switch in FCL are simulated.The results show that maximum DC component of the short-circuit current of the high-speed switch reaches 91%,the maximum peak value is 118 kA,and the longest arcing time is 14.8 ms.There is a discontinuity in the curve of the short-circuit current peak and arcing time as a function of the short-circuit occurrence time;the peak recovery voltage of a single break of the high-speed switch has a maximum value of 87.5 kV under a three-phase ungrounded short-circuit condition,and the rate of rise of recovery voltage is o.22 kV/s.The recovery voltage peak shows a period change with the short-circuit occurrence time,and the period is 10 ms.The effects of the shunt capacitor value and short-circuit ground resistance on the recovery voltage of high-speed switching are also studied.The research can be used for reference by R&D personnel and testersof500kVFCLs.Index Terms-Fault current limiter(FCL),high coupled split reactor(HCSR),high-speed switch,interruption characteristics,short circuit current. 展开更多
关键词 Fault current limiter(FCL) high coupled split reactor(HCSR) high-speed switch interruption characteristics short circuit current.
原文传递