[Objective] The study aimed to discuss the application of boron-doped diamond (BDD) film electrode in fast detection of samonella in water. [ Method] Boron-doped diamond film electrode was prepared and used as the w...[Objective] The study aimed to discuss the application of boron-doped diamond (BDD) film electrode in fast detection of samonella in water. [ Method] Boron-doped diamond film electrode was prepared and used as the working electrode in fast detection of salmonella in water using chronoamberometry, and the oxidation mechanism of the electrode acting on salmonella was discussed. [ Result] Compared with traditional biologi- cal methods, chronoamperometry could detect the number of salmonellae in water more simply, rapidly and sensitively. [ Conclusion] The method of using BDD electrode to detect salmonella quantity will be widely applied in future.展开更多
[ Objective] Based on salicylic acid culture solution, high performance liquid chromatography (HPLC) was used to rapidly count E. coli in water. [Method] Because E. coli metabolism could produce polyatomic phenol (...[ Objective] Based on salicylic acid culture solution, high performance liquid chromatography (HPLC) was used to rapidly count E. coli in water. [Method] Because E. coli metabolism could produce polyatomic phenol (mainly 2, 5-dihydroxybenzoic acid) in salicylic acid culture solu- tion, and generated amount of polyatomic phenol was proportionate to the number of E. coli, we detected 2, 5-dihydroxybenzoic acid by HPLC. Through linear relationship, the number of E. co/i was calculated, realizing fast counting of E. coli, and detection time only needed 3 h. [ Result] Linearity range of the method detecting E. coli was 5 × 10^4 -5 × 10^10cells/ml, and the detection limit was 1 × 10^4 cells/ml. [ Conclusion] HPLC method realized rapid counting of E. coil Key words E. coli; Fast counting; HPLC; Salicylic acid; China展开更多
基金the Project of General Administration of Quality Supervision,Inspection and Quarantine of the People's Republic of China(2011QK345)Natural Science Foundation of Guangxi,China(0728048)
文摘[Objective] The study aimed to discuss the application of boron-doped diamond (BDD) film electrode in fast detection of samonella in water. [ Method] Boron-doped diamond film electrode was prepared and used as the working electrode in fast detection of salmonella in water using chronoamberometry, and the oxidation mechanism of the electrode acting on salmonella was discussed. [ Result] Compared with traditional biologi- cal methods, chronoamperometry could detect the number of salmonellae in water more simply, rapidly and sensitively. [ Conclusion] The method of using BDD electrode to detect salmonella quantity will be widely applied in future.
基金Supported by Plan Item of National Bureau of Quality Inspection,China(2011QK345)Natural Science Foundation Item of Guangxi,China(Guikezi0728048)
文摘[ Objective] Based on salicylic acid culture solution, high performance liquid chromatography (HPLC) was used to rapidly count E. coli in water. [Method] Because E. coli metabolism could produce polyatomic phenol (mainly 2, 5-dihydroxybenzoic acid) in salicylic acid culture solu- tion, and generated amount of polyatomic phenol was proportionate to the number of E. coli, we detected 2, 5-dihydroxybenzoic acid by HPLC. Through linear relationship, the number of E. co/i was calculated, realizing fast counting of E. coli, and detection time only needed 3 h. [ Result] Linearity range of the method detecting E. coli was 5 × 10^4 -5 × 10^10cells/ml, and the detection limit was 1 × 10^4 cells/ml. [ Conclusion] HPLC method realized rapid counting of E. coil Key words E. coli; Fast counting; HPLC; Salicylic acid; China