A live line measurement method for the zero sequence parameters of transmission lines with mutual inductance is introduced. The mathematical models of the measurement method are given. Global Positioning System (GPS) ...A live line measurement method for the zero sequence parameters of transmission lines with mutual inductance is introduced. The mathematical models of the measurement method are given. Global Positioning System (GPS) is used as the synchronous signal for the measurement carried out at different substations simultaneously. The measurement system and digital simulation results are given. Finally, the live line measurement results of two 220 kV transmission lines with mutual inductance in Hainangrid are given. Results from both simulation and on-site measurement show that the live line measurement method is feasible, and its measurement accuracy can satisfactorily meet the requirements of engineering measurement.展开更多
Effective model reduction methods are required to deal with new challenges in active distribution network simulations that are on a large scale and have complicated structures.In the development of advanced electromag...Effective model reduction methods are required to deal with new challenges in active distribution network simulations that are on a large scale and have complicated structures.In the development of advanced electromagnetic transient simulation programs,automated model reduction plays an important role.This paper proposes an automated realization algorithm for the Krylov subspace based model reduction methods of an active distribution network with which the reduced model can be automatically established according to a given threshold of reduction error.The combined state-space nodal analysis framework is employed to apply the automated model reduction algorithm in popular EMTP-type simulation programs.Simulations are performed using PSCAD and a self-developed program to show the feasibility and validity of the proposed methods.展开更多
文摘A live line measurement method for the zero sequence parameters of transmission lines with mutual inductance is introduced. The mathematical models of the measurement method are given. Global Positioning System (GPS) is used as the synchronous signal for the measurement carried out at different substations simultaneously. The measurement system and digital simulation results are given. Finally, the live line measurement results of two 220 kV transmission lines with mutual inductance in Hainangrid are given. Results from both simulation and on-site measurement show that the live line measurement method is feasible, and its measurement accuracy can satisfactorily meet the requirements of engineering measurement.
基金supported in part by the National Key Technology Research and Development Program of China(2013BAAOlB03)in part by the National Natural Science Foundation of China(51261130473).
文摘Effective model reduction methods are required to deal with new challenges in active distribution network simulations that are on a large scale and have complicated structures.In the development of advanced electromagnetic transient simulation programs,automated model reduction plays an important role.This paper proposes an automated realization algorithm for the Krylov subspace based model reduction methods of an active distribution network with which the reduced model can be automatically established according to a given threshold of reduction error.The combined state-space nodal analysis framework is employed to apply the automated model reduction algorithm in popular EMTP-type simulation programs.Simulations are performed using PSCAD and a self-developed program to show the feasibility and validity of the proposed methods.