Background:The benefits associated with sports compression garments are thought to be closely related to enhanced blood flow.However,findings are equivocal,possibly due to heterogeneity in the techniques used for meas...Background:The benefits associated with sports compression garments are thought to be closely related to enhanced blood flow.However,findings are equivocal,possibly due to heterogeneity in the techniques used for measuring blood flow,the garment types used,and the pressures applied.This study combined Doppler ultrasound and near-infrared spectroscopy technologies to provide the first comprehensive assessment of the effects of 3 sports compression garment types on markers of venous return and muscle blood flow at rest.Methods:Resting lower-limb blood flow measures(markers of venous return,muscle blood flow,and muscle oxygenation)of 22 elite,junior,male basketball players(age=17.2±0.9 years,mean±SD)were assessed in 4 separate conditions:no compression(CON),compression tights(TIGHTS),compression shorts(SHORTS),and compression socks(SOCKS).Markers of venous return(cross-sectional area,time-averaged mean and peak blood flow velocity,and venous blood flow)were measured via Doppler ultrasound at the popliteal and common femoral veins.Muscle blood flow and muscle oxygenation were measured in the gastrocnemius medialis and vastus lateralis using near-infrared spectroscopy.Results:Popliteal markers of venous return were higher in TIGHTS compared to CON(p<0.01)and SHORTS(p<0.01),with SOCKS values higher compared with CON(p<0.05).Common femoral vein markers of venous return were higher for all conditions compared to CON(p<0.05),with TIGHTS values also higher compared to SOCKS(p<0.05).Gastrocnemius medialis blood flow was higher for TIGHTS compared to CON(p=0.000),SOCKS(p=0.012),and SHORTS(p=0.000),with SOCKS higher compared to SHORTS(p=0.046).Vastus lateralis blood flow was higher for TIGHTS compared to CON(p=0.028)and SOCKS(p=0.019),with SHORTS also higher compared to CON(p=0.012)and SOCKS(p=0.005).Gastrocnemius medialis oxygenation was higher for TIGHTS compared to CON(p=0.003),SOCKS(p=0.033),and SHORTS(p=0.003),with SOCKS higher compared to CON(p=0.044)and SHORTS(p=0.032).Vastus lateralis oxygenation was higher for TIGHTS compared to CON(p=0.020)and SOCKS(p=0.006).Conclusion:Markers of venous return,muscle blood flow,and muscle oxygenation are increased with sports compression garments.TIGHTS are most effective,potentially because of the larger body area compressed.展开更多
The underlying literature hypothesises and provides randomised evidence for the positive impact of promoting the broad-based inclusion,empowerment,and representation of women on regional ecosystems.This study seeks to...The underlying literature hypothesises and provides randomised evidence for the positive impact of promoting the broad-based inclusion,empowerment,and representation of women on regional ecosystems.This study seeks to isolate a female agencydriven development factor in external sovereign emerging market debt and finds evidence for superior risk-adjusted returns from tilting towards female agency leaders.We propose the female agency factor as an additional scope in the modern investor’s toolbox of holistic credit assessment,allowing investors to isolate the issuers which are the most effective sovereign transmission mechanisms of sustainable development capital.This contribution to the corpus supports the notion of integrating sustainability factors into portfolio construction and reinforces the argument for supporting femaleled development from a financial markets’perspective.展开更多
The programmable metasurface(PM)is an antenna array architecture that realizes flexible beam steering.This functionality is achieved by controlling the unit cells designed with micro components such as positive-intrin...The programmable metasurface(PM)is an antenna array architecture that realizes flexible beam steering.This functionality is achieved by controlling the unit cells designed with micro components such as positive-intrinsic-negative(PIN)diodes,which offers potential cost reductions in the next generation wireless communication systems.Although PM has been a popular topic in antenna design,its implementations in real-time systems accompanied by signal processing algorithms are challenging.In this paper,novel predictive tracking algorithms for mobile communication scenarios using a PM are created and implemented in a real-time system operating at 28 GHz.An angular speed prediction(ASP)algorithm is proposed to compute the position of user equipment(UE)based on the previously recorded beam directions.As another solution,an angle correction(AC)algorithm is proposed to further improve the prediction and tracking accuracy.As a benchmark,the comparisons to a previous PM tracking algorithm without prediction are presented.Both simulation and measurement results show that the prediction algorithms successfully improve the tracking performance,which also prove the feasibilities of PM-based systems to solve complex real-time signal processing problems.展开更多
Acute Kidney Injury (AKI) is a condition that causes nephrotoxicity in kidney tissues due to cisplatin-induced cancer treatments. Hence, it is proposed in this review that AVE0991 (a MAS-receptor Angiotensin II (1-7) ...Acute Kidney Injury (AKI) is a condition that causes nephrotoxicity in kidney tissues due to cisplatin-induced cancer treatments. Hence, it is proposed in this review that AVE0991 (a MAS-receptor Angiotensin II (1-7) agonist) may reduce cisplatin-induced acute kidney injury by promoting nitric oxide production.展开更多
文摘Background:The benefits associated with sports compression garments are thought to be closely related to enhanced blood flow.However,findings are equivocal,possibly due to heterogeneity in the techniques used for measuring blood flow,the garment types used,and the pressures applied.This study combined Doppler ultrasound and near-infrared spectroscopy technologies to provide the first comprehensive assessment of the effects of 3 sports compression garment types on markers of venous return and muscle blood flow at rest.Methods:Resting lower-limb blood flow measures(markers of venous return,muscle blood flow,and muscle oxygenation)of 22 elite,junior,male basketball players(age=17.2±0.9 years,mean±SD)were assessed in 4 separate conditions:no compression(CON),compression tights(TIGHTS),compression shorts(SHORTS),and compression socks(SOCKS).Markers of venous return(cross-sectional area,time-averaged mean and peak blood flow velocity,and venous blood flow)were measured via Doppler ultrasound at the popliteal and common femoral veins.Muscle blood flow and muscle oxygenation were measured in the gastrocnemius medialis and vastus lateralis using near-infrared spectroscopy.Results:Popliteal markers of venous return were higher in TIGHTS compared to CON(p<0.01)and SHORTS(p<0.01),with SOCKS values higher compared with CON(p<0.05).Common femoral vein markers of venous return were higher for all conditions compared to CON(p<0.05),with TIGHTS values also higher compared to SOCKS(p<0.05).Gastrocnemius medialis blood flow was higher for TIGHTS compared to CON(p=0.000),SOCKS(p=0.012),and SHORTS(p=0.000),with SOCKS higher compared to SHORTS(p=0.046).Vastus lateralis blood flow was higher for TIGHTS compared to CON(p=0.028)and SOCKS(p=0.019),with SHORTS also higher compared to CON(p=0.012)and SOCKS(p=0.005).Gastrocnemius medialis oxygenation was higher for TIGHTS compared to CON(p=0.003),SOCKS(p=0.033),and SHORTS(p=0.003),with SOCKS higher compared to CON(p=0.044)and SHORTS(p=0.032).Vastus lateralis oxygenation was higher for TIGHTS compared to CON(p=0.020)and SOCKS(p=0.006).Conclusion:Markers of venous return,muscle blood flow,and muscle oxygenation are increased with sports compression garments.TIGHTS are most effective,potentially because of the larger body area compressed.
文摘The underlying literature hypothesises and provides randomised evidence for the positive impact of promoting the broad-based inclusion,empowerment,and representation of women on regional ecosystems.This study seeks to isolate a female agencydriven development factor in external sovereign emerging market debt and finds evidence for superior risk-adjusted returns from tilting towards female agency leaders.We propose the female agency factor as an additional scope in the modern investor’s toolbox of holistic credit assessment,allowing investors to isolate the issuers which are the most effective sovereign transmission mechanisms of sustainable development capital.This contribution to the corpus supports the notion of integrating sustainability factors into portfolio construction and reinforces the argument for supporting femaleled development from a financial markets’perspective.
文摘The programmable metasurface(PM)is an antenna array architecture that realizes flexible beam steering.This functionality is achieved by controlling the unit cells designed with micro components such as positive-intrinsic-negative(PIN)diodes,which offers potential cost reductions in the next generation wireless communication systems.Although PM has been a popular topic in antenna design,its implementations in real-time systems accompanied by signal processing algorithms are challenging.In this paper,novel predictive tracking algorithms for mobile communication scenarios using a PM are created and implemented in a real-time system operating at 28 GHz.An angular speed prediction(ASP)algorithm is proposed to compute the position of user equipment(UE)based on the previously recorded beam directions.As another solution,an angle correction(AC)algorithm is proposed to further improve the prediction and tracking accuracy.As a benchmark,the comparisons to a previous PM tracking algorithm without prediction are presented.Both simulation and measurement results show that the prediction algorithms successfully improve the tracking performance,which also prove the feasibilities of PM-based systems to solve complex real-time signal processing problems.
文摘Acute Kidney Injury (AKI) is a condition that causes nephrotoxicity in kidney tissues due to cisplatin-induced cancer treatments. Hence, it is proposed in this review that AVE0991 (a MAS-receptor Angiotensin II (1-7) agonist) may reduce cisplatin-induced acute kidney injury by promoting nitric oxide production.