A pair of stainless steel (ss) plates separates the source and target regions of a double plasma device. Two sets of tungsten filaments, placed at different distances from the ss plates, are then used to produce plasm...A pair of stainless steel (ss) plates separates the source and target regions of a double plasma device. Two sets of tungsten filaments, placed at different distances from the ss plates, are then used to produce plasma alternately and the plasma parameters in the source and target regions for different discharge voltage, discharge current and plate separation are measured using Langmuir probes. It is found that plasma density and electron temperature are considerably affected and respond differently to changes in the plate separations and the position of the filaments.展开更多
文摘A pair of stainless steel (ss) plates separates the source and target regions of a double plasma device. Two sets of tungsten filaments, placed at different distances from the ss plates, are then used to produce plasma alternately and the plasma parameters in the source and target regions for different discharge voltage, discharge current and plate separation are measured using Langmuir probes. It is found that plasma density and electron temperature are considerably affected and respond differently to changes in the plate separations and the position of the filaments.