To estimate nutrient budgets,water samples were collected at 16 sites in Tapong lagoon from January 2004 through April 2005 and the parameters of water quality were analyzed immediately after collection.These data wer...To estimate nutrient budgets,water samples were collected at 16 sites in Tapong lagoon from January 2004 through April 2005 and the parameters of water quality were analyzed immediately after collection.These data were used to build a box model for calculating nutrient budgets of the lagoon.We estimated the net amount of nutrient fluxes into (coming from creeks) and out (from tidal inlet) of the lagoon and calculated the total amount of nutrient that deposits into the sediment in a full tidal cycle.During January and April,nutrients (including nitrate,nitrite and ammonia) accumulated in the lagoon,but phosphate,total phosphate and suspended solids were flushed out of the lagoon from the tidal inlet.In addition,a huge amount of suspended solids (13-15 tons per tidal cycle) flew from the lagoon to the adjacent ocean through the inlet-outlet channel.展开更多
Conducting anodic stripping voltammetry (ASV) to determine non-labile-form metal in a water sample usually requires UV digestion. The time for thoroughly disintegrating metal complexes is lengthy and completion of dig...Conducting anodic stripping voltammetry (ASV) to determine non-labile-form metal in a water sample usually requires UV digestion. The time for thoroughly disintegrating metal complexes is lengthy and completion of digestion is not easy to determine. In this study, the degree of dissociation of copper complex, indicated by the ratio of slope changes at ASV titration, was found to be linearly correlated with UV irradiation time (r 2 = 0.976). Using slope changes, an equation for estimating the length of UV irradiation time was developed. If the estimated UV digestion time was too long, the same data set could be used to estimate the total concentration of the element using another equation developed from the linear correlation (r 2 = 0.990) between the concentration of labile form metal ion and UV irradiation time. The reliability and feasibility of this method were confirmed with standard addition (error < 20%; recovery: 97.5 ± 10.9%).展开更多
基金supported by "Dapeng Bay National Science Area Administration"
文摘To estimate nutrient budgets,water samples were collected at 16 sites in Tapong lagoon from January 2004 through April 2005 and the parameters of water quality were analyzed immediately after collection.These data were used to build a box model for calculating nutrient budgets of the lagoon.We estimated the net amount of nutrient fluxes into (coming from creeks) and out (from tidal inlet) of the lagoon and calculated the total amount of nutrient that deposits into the sediment in a full tidal cycle.During January and April,nutrients (including nitrate,nitrite and ammonia) accumulated in the lagoon,but phosphate,total phosphate and suspended solids were flushed out of the lagoon from the tidal inlet.In addition,a huge amount of suspended solids (13-15 tons per tidal cycle) flew from the lagoon to the adjacent ocean through the inlet-outlet channel.
基金supported by "National Science Council" (Grant No.NSC90-2313-B-291-001)
文摘Conducting anodic stripping voltammetry (ASV) to determine non-labile-form metal in a water sample usually requires UV digestion. The time for thoroughly disintegrating metal complexes is lengthy and completion of digestion is not easy to determine. In this study, the degree of dissociation of copper complex, indicated by the ratio of slope changes at ASV titration, was found to be linearly correlated with UV irradiation time (r 2 = 0.976). Using slope changes, an equation for estimating the length of UV irradiation time was developed. If the estimated UV digestion time was too long, the same data set could be used to estimate the total concentration of the element using another equation developed from the linear correlation (r 2 = 0.990) between the concentration of labile form metal ion and UV irradiation time. The reliability and feasibility of this method were confirmed with standard addition (error < 20%; recovery: 97.5 ± 10.9%).