It is very important to predict the coupling between the cavity and the high power input source in the coupler design. In this paper, a time domain method is used to calculate the external quality factor Qext for the ...It is very important to predict the coupling between the cavity and the high power input source in the coupler design. In this paper, a time domain method is used to calculate the external quality factor Qext for the BEPC Ⅱ superconducting cavity. A comparison between simulation results and experimental results is presented. The results of simulation and measurement of Qext have a good agreement within an error of 10%. The geometry parameters related with Qext are also studied.展开更多
基金Supported by National Natural Science Foundation of China(k711360503)
文摘It is very important to predict the coupling between the cavity and the high power input source in the coupler design. In this paper, a time domain method is used to calculate the external quality factor Qext for the BEPC Ⅱ superconducting cavity. A comparison between simulation results and experimental results is presented. The results of simulation and measurement of Qext have a good agreement within an error of 10%. The geometry parameters related with Qext are also studied.