Increased grid integration of photovoltaic(PV)has aggravated the uncertainty of distribution network operations.For a distribution network with PV,the impact of the PV location on the network power losses and voltage ...Increased grid integration of photovoltaic(PV)has aggravated the uncertainty of distribution network operations.For a distribution network with PV,the impact of the PV location on the network power losses and voltage fluctuations is investigated with analytical derivations reflected by the line impedance.Optimization approaches of the PV location with consideration of two aspects,i.e.,minimum network power losses and minimum voltage fluctuations,are analyzed.A particle swarm optimization(PSO)algorithm is used to synthesize an optimal compromised solution so as to determine the PV location.A 10 kV distribution network with one PV is established on the time-domain simulation environment PSCAD/EMTDC.The simulation results justify the theoretical analysis and indicate that when the active power of the PV is more/less than twice that of the overall loads/end loads,the network power losses and node voltage fluctuations are both minimum when the PV is integrated into the head/tail end of the network.When the active power of the PV is between the above two conditions,nodes t/f can be identified for the integration of the PV between the head/end nodes of the network to achieve the minimum network power losses/voltage fluctuations,respectively.The effectiveness of the proposed optimization approach is verified and can provide a reference for selecting the PV location in the distribution network.展开更多
There are various types of distributed generators (DGs) with different grid integration strategies. The transient characteristics of the fault currents provided by the DGs are different to those of conventional synchr...There are various types of distributed generators (DGs) with different grid integration strategies. The transient characteristics of the fault currents provided by the DGs are different to those of conventional synchronous generators. In this paper, a distribution network with multi-type DGs is investigated, including consideration of DG low-voltage ride through (LVRT). The fault current characteristics of two typical DGs, i.e. an inverter-interfaced distributed generator (IIDG) and a doubly-fed induction generator (DFIG), are analyzed, considering the specific operation modes. Based on analysis of the fault characteristics, an equivalent model of the multi-type DGs under symmetrical/asymmetrical fault conditions is established. A fast-iterative fault calculation method for enhancing the calculation efficiency while avoiding local convergence is then proposed using an improved particle swarm optimization (PSO) algorithm. A simulation system of the distribution network with multi-type DGs is established in PSCAD/EMTDC. The simulation results validate the high accuracy and calculation efficiency of the proposed calculation method of the fault components. This can assist in the settings of the protection threshold.展开更多
基金This work was supported by National Natural Science Foundation of China under Grant 51807091Natural Science Foundation of Jiangsu Province BK20180478+1 种基金the China Postdoctoral Science Foundation under Grant 2019M661846,EPSRC under Grant EP/N032888/1the International Science and Technology Collaborative Project of Policy Guidance Plan of Jiangsu Province under Grant BZ2018026。
文摘Increased grid integration of photovoltaic(PV)has aggravated the uncertainty of distribution network operations.For a distribution network with PV,the impact of the PV location on the network power losses and voltage fluctuations is investigated with analytical derivations reflected by the line impedance.Optimization approaches of the PV location with consideration of two aspects,i.e.,minimum network power losses and minimum voltage fluctuations,are analyzed.A particle swarm optimization(PSO)algorithm is used to synthesize an optimal compromised solution so as to determine the PV location.A 10 kV distribution network with one PV is established on the time-domain simulation environment PSCAD/EMTDC.The simulation results justify the theoretical analysis and indicate that when the active power of the PV is more/less than twice that of the overall loads/end loads,the network power losses and node voltage fluctuations are both minimum when the PV is integrated into the head/tail end of the network.When the active power of the PV is between the above two conditions,nodes t/f can be identified for the integration of the PV between the head/end nodes of the network to achieve the minimum network power losses/voltage fluctuations,respectively.The effectiveness of the proposed optimization approach is verified and can provide a reference for selecting the PV location in the distribution network.
基金supported by National Natural Science Foundation of China under Grant 51807091the China Postdoctoral Science Foundation under Grant 2019M661846Open Research Fund of Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education,EPSRC under Grant EP/N032888/1,and the International Science and Technology Collaborative Project of Policy Guidance Plan of Jiangsu Province under Grant BZ2018026.
文摘There are various types of distributed generators (DGs) with different grid integration strategies. The transient characteristics of the fault currents provided by the DGs are different to those of conventional synchronous generators. In this paper, a distribution network with multi-type DGs is investigated, including consideration of DG low-voltage ride through (LVRT). The fault current characteristics of two typical DGs, i.e. an inverter-interfaced distributed generator (IIDG) and a doubly-fed induction generator (DFIG), are analyzed, considering the specific operation modes. Based on analysis of the fault characteristics, an equivalent model of the multi-type DGs under symmetrical/asymmetrical fault conditions is established. A fast-iterative fault calculation method for enhancing the calculation efficiency while avoiding local convergence is then proposed using an improved particle swarm optimization (PSO) algorithm. A simulation system of the distribution network with multi-type DGs is established in PSCAD/EMTDC. The simulation results validate the high accuracy and calculation efficiency of the proposed calculation method of the fault components. This can assist in the settings of the protection threshold.