A rapid quantitative analytical method for three components of Lonicerae Japornicae Flos solution(Lonicera Japonica Thumb.)extracted by water was developed using near-infrared(NIR)spectroscopy and the partial least-sq...A rapid quantitative analytical method for three components of Lonicerae Japornicae Flos solution(Lonicera Japonica Thumb.)extracted by water was developed using near-infrared(NIR)spectroscopy and the partial least-squares(PLS)method.The NIR spectra of 81 samples collected from a production line were obtained.The concentrations of secologanic acid,chlorogenicacid and galuteolin were detemmined by using high-performance liquid chromatography-diodearray detection as the reference method.Several pretreatment methods for the NIR spectra wereusedi during PLS calibration.The most appropriate latent variable number of the PLS factor wasselected based on the standard error of cross-validation(SECV).The performance of the finalPLS models was evaluated according to SECV,standard error of predliction(SEP)and deter-mination coeficient(R^(2)).The compounds secologanic acid,chlorogenic acid and galuteolin hadSEP values of 0.030,0.061 and 1.668μg/mL,respectively and R^(2) values over 0.85.This workshows that NIR spectroscopy is a rapid and convenient method for the analysis of LoniceraeJaponicae Flos solution extracted by water.The proposed method can help in the application ofprocs analytical technology in the pha maceutical industry,particularly in tra ditional Chinesemedicine injections.展开更多
基金Financial support was received from the National High-tech Industry Development Project of National Development and Reform Commission(Nos.2007-2490).
文摘A rapid quantitative analytical method for three components of Lonicerae Japornicae Flos solution(Lonicera Japonica Thumb.)extracted by water was developed using near-infrared(NIR)spectroscopy and the partial least-squares(PLS)method.The NIR spectra of 81 samples collected from a production line were obtained.The concentrations of secologanic acid,chlorogenicacid and galuteolin were detemmined by using high-performance liquid chromatography-diodearray detection as the reference method.Several pretreatment methods for the NIR spectra wereusedi during PLS calibration.The most appropriate latent variable number of the PLS factor wasselected based on the standard error of cross-validation(SECV).The performance of the finalPLS models was evaluated according to SECV,standard error of predliction(SEP)and deter-mination coeficient(R^(2)).The compounds secologanic acid,chlorogenic acid and galuteolin hadSEP values of 0.030,0.061 and 1.668μg/mL,respectively and R^(2) values over 0.85.This workshows that NIR spectroscopy is a rapid and convenient method for the analysis of LoniceraeJaponicae Flos solution extracted by water.The proposed method can help in the application ofprocs analytical technology in the pha maceutical industry,particularly in tra ditional Chinesemedicine injections.