Simultaneous in-situ determination of U-Pb ages and 20 trace elements of three international zircon standards(91500,GJ1 and TEMORA 1) and one laboratory zircon standard(SK10-2) separated from Cenozoic fine-grained gab...Simultaneous in-situ determination of U-Pb ages and 20 trace elements of three international zircon standards(91500,GJ1 and TEMORA 1) and one laboratory zircon standard(SK10-2) separated from Cenozoic fine-grained gabbro was carried out on quadrupole ICP-MS equipped with 193 nm excimer laser in 20 μm spot size. The weighted mean 206Pb/238U ages of 91500,GJ1 and TEMORA 1 are 1064.4±4.8 Ma(2σ ),603.2±2.4 Ma(2σ ) and 418.2±2.4 Ma(2σ ),respectively. The relative standard de-viations(RSDs) of 206Pb/238U ages(2σ ) are less than 2.2% for single measurements and 0.6% for weighted means. The obtained weighted mean 206Pb/238U ages of three standard zircons agree with the recommended values within 2σ error. The weighted mean 206Pb/238U age of SK10-2 is 31.42±0.25 Ma(2σ ) and the RSDs of 206Pb/238U ages(2σ ) are between 2.4% and 5.7% for single measurements and less than 0.8% for weighted mean. The obtained weighted mean 206Pb/238U age is in good agreement with the age obtained by Yuan(2004). Trace element concentrations of NIST612 and NIST614 obtained under the same LA-ICP-MS operating conditions agree with the recommended values within analytical error. The results indicate that it is possible to measure U-Pb age and trace elements simultaneously by LA-ICP-MS in a small spot size of 20 μm.展开更多
基金Supported by the National Natural Science Foundation of China (Grant Nos.40472099, 40521001 and 40673019)Chinese Ministry of Education (Grant Nos.IRT0441 and 306021)
文摘Simultaneous in-situ determination of U-Pb ages and 20 trace elements of three international zircon standards(91500,GJ1 and TEMORA 1) and one laboratory zircon standard(SK10-2) separated from Cenozoic fine-grained gabbro was carried out on quadrupole ICP-MS equipped with 193 nm excimer laser in 20 μm spot size. The weighted mean 206Pb/238U ages of 91500,GJ1 and TEMORA 1 are 1064.4±4.8 Ma(2σ ),603.2±2.4 Ma(2σ ) and 418.2±2.4 Ma(2σ ),respectively. The relative standard de-viations(RSDs) of 206Pb/238U ages(2σ ) are less than 2.2% for single measurements and 0.6% for weighted means. The obtained weighted mean 206Pb/238U ages of three standard zircons agree with the recommended values within 2σ error. The weighted mean 206Pb/238U age of SK10-2 is 31.42±0.25 Ma(2σ ) and the RSDs of 206Pb/238U ages(2σ ) are between 2.4% and 5.7% for single measurements and less than 0.8% for weighted mean. The obtained weighted mean 206Pb/238U age is in good agreement with the age obtained by Yuan(2004). Trace element concentrations of NIST612 and NIST614 obtained under the same LA-ICP-MS operating conditions agree with the recommended values within analytical error. The results indicate that it is possible to measure U-Pb age and trace elements simultaneously by LA-ICP-MS in a small spot size of 20 μm.