Background:Accurate quantification of voluntary activation is important for understanding the extent of quadriceps dysfunction in individuals with anterior cruciate ligament reconstruction(ACLR).Voluntary activation h...Background:Accurate quantification of voluntary activation is important for understanding the extent of quadriceps dysfunction in individuals with anterior cruciate ligament reconstruction(ACLR).Voluntary activation has been quantified using both percent activation derived from the interpolated twitch technique and central activation ratio(CAR)derived from the burst superimposition technique,as well as by using different types of electrical stimulators and pulse train conditions.However,it is unclear how these parameters affect voluntary activation estimates in individuals with ACLR.This study was performed to fill this important knowledge gap in the anterior cruciate ligament literature.Methods:Quadriceps strength and voluntary activation were examined in 18 ACLR participants(12 quadriceps/patellartendon graft,6 hamstring tendon graft;time since ACLR:1.06±0.82 years,mean±SD)at 90°of knee flexion using 2 stimulators(Digitimer and Grass)and pulse train conditions(3-pulse and 10-pulse).Voluntary activation was quantified by calculating both CAR and percent activation.Results:Results indicated that voluntary activation was significantly overestimated by CAR when compared with percent activation(p<0.001).Voluntary activation estimates were not affected by pulse train conditions when using percent activation;however,3-pulse stimuli resulted in greater overestimation than 10-pulse stimuli when using CAR(p=0.003).Voluntary activation did not differ between stimulators(p>0.05);however,the Digitimer evoked greater torque at rest than the Grass(p<0.001).Conclusion:These results indicate that percent activation derived from the interpolated twitch technique provides superior estimates of voluntary activation than CAR derived from burst superimposition and is less affected by pulse train conditions or stimulators in individuals with ACLR.展开更多
基金partly supported by the National Institute of Child Health and Human Development of the National Institutes of Health(Grant No.R21 HD092614)。
文摘Background:Accurate quantification of voluntary activation is important for understanding the extent of quadriceps dysfunction in individuals with anterior cruciate ligament reconstruction(ACLR).Voluntary activation has been quantified using both percent activation derived from the interpolated twitch technique and central activation ratio(CAR)derived from the burst superimposition technique,as well as by using different types of electrical stimulators and pulse train conditions.However,it is unclear how these parameters affect voluntary activation estimates in individuals with ACLR.This study was performed to fill this important knowledge gap in the anterior cruciate ligament literature.Methods:Quadriceps strength and voluntary activation were examined in 18 ACLR participants(12 quadriceps/patellartendon graft,6 hamstring tendon graft;time since ACLR:1.06±0.82 years,mean±SD)at 90°of knee flexion using 2 stimulators(Digitimer and Grass)and pulse train conditions(3-pulse and 10-pulse).Voluntary activation was quantified by calculating both CAR and percent activation.Results:Results indicated that voluntary activation was significantly overestimated by CAR when compared with percent activation(p<0.001).Voluntary activation estimates were not affected by pulse train conditions when using percent activation;however,3-pulse stimuli resulted in greater overestimation than 10-pulse stimuli when using CAR(p=0.003).Voluntary activation did not differ between stimulators(p>0.05);however,the Digitimer evoked greater torque at rest than the Grass(p<0.001).Conclusion:These results indicate that percent activation derived from the interpolated twitch technique provides superior estimates of voluntary activation than CAR derived from burst superimposition and is less affected by pulse train conditions or stimulators in individuals with ACLR.