Reponses of structures subjected to severe earthquakes sometimes significantly surpass what was considered in the design.It is important to investigate the failure mechanism and collapse margin of structures beyond de...Reponses of structures subjected to severe earthquakes sometimes significantly surpass what was considered in the design.It is important to investigate the failure mechanism and collapse margin of structures beyond design,especially for high-rise buildings.In this study,steel high-rise buildings using either square concrete-filled-tube(CFT) columns or steel tube columns are designed.A detailed three-dimensional(3 D) structural model is developed to analyze the seismic behavior of a steel high-rise towards a complete collapse.The effectiveness is verified by both component tests and a full-scale shaking table test.The collapse margin,which is defined as the ratio of PGA between the collapse level to the design major earthquake level(Level 2),is quantified by a series of numerical simulations using incremental dynamic analyses(IDA).The baseline building using CFT columns collapsed with a weak first story mechanism and presented a collapse margin ranging from 10 to 20.The significant variation in the collapse margin was caused by the different characteristics of the input ground motions.The building using equivalent steel columns collapsed earlier due to the significant shortening of the locally buckled columns,exhibiting only 57% of the collapse margin of the baseline building.The influence of reducing the height of the first story was quite significant.The shortened first story not only enlarged the collapse margin by 20%,but also changed the collapse mode.展开更多
Traditional agriculture is in the direction of increasing integration of the primary industry, secondary industry, and tertiary industry in Zhejiang province. A survey was undertaken on energy consumption of tradition...Traditional agriculture is in the direction of increasing integration of the primary industry, secondary industry, and tertiary industry in Zhejiang province. A survey was undertaken on energy consumption of traditional natural villages by taking Anji Ligeng village for an example. This paper firstly studied rural buildings, rural family structure, occupants’ activity and the usage of household appliances in the form of a questionnaire. Then, the household energy resource structure and energy consumption structure were analyzed and compared with other surveys. The results show that, the electric energy consumption was 6 kWh/(m<sup>2</sup>•a), which was far less than urban residential household. In rural household energy resource structure, the proportion of non-commercial energy resource was higher than commercial energy resource. Firewood accounted for 83%, electricity for 12%, LPG for 3% and solar energy for 2%. In building energy consumption structure, cooking and hot water took up 33%, appliances 31%, lighting 20%, heating 12%, cooling 4%. In all influential factors, frequently used area, number of air conditioner per household and building function were obviously correlated with energy consumption;income, building shape factor and window to wall area ratio had no correlation with energy consumption in the low energy consumption area.展开更多
基金Heilongjiang Province Application Technology Research and Development under Grant No.GX16C007National Key Research and Development Program of China under Grant No.2017YFC1500605
文摘Reponses of structures subjected to severe earthquakes sometimes significantly surpass what was considered in the design.It is important to investigate the failure mechanism and collapse margin of structures beyond design,especially for high-rise buildings.In this study,steel high-rise buildings using either square concrete-filled-tube(CFT) columns or steel tube columns are designed.A detailed three-dimensional(3 D) structural model is developed to analyze the seismic behavior of a steel high-rise towards a complete collapse.The effectiveness is verified by both component tests and a full-scale shaking table test.The collapse margin,which is defined as the ratio of PGA between the collapse level to the design major earthquake level(Level 2),is quantified by a series of numerical simulations using incremental dynamic analyses(IDA).The baseline building using CFT columns collapsed with a weak first story mechanism and presented a collapse margin ranging from 10 to 20.The significant variation in the collapse margin was caused by the different characteristics of the input ground motions.The building using equivalent steel columns collapsed earlier due to the significant shortening of the locally buckled columns,exhibiting only 57% of the collapse margin of the baseline building.The influence of reducing the height of the first story was quite significant.The shortened first story not only enlarged the collapse margin by 20%,but also changed the collapse mode.
文摘Traditional agriculture is in the direction of increasing integration of the primary industry, secondary industry, and tertiary industry in Zhejiang province. A survey was undertaken on energy consumption of traditional natural villages by taking Anji Ligeng village for an example. This paper firstly studied rural buildings, rural family structure, occupants’ activity and the usage of household appliances in the form of a questionnaire. Then, the household energy resource structure and energy consumption structure were analyzed and compared with other surveys. The results show that, the electric energy consumption was 6 kWh/(m<sup>2</sup>•a), which was far less than urban residential household. In rural household energy resource structure, the proportion of non-commercial energy resource was higher than commercial energy resource. Firewood accounted for 83%, electricity for 12%, LPG for 3% and solar energy for 2%. In building energy consumption structure, cooking and hot water took up 33%, appliances 31%, lighting 20%, heating 12%, cooling 4%. In all influential factors, frequently used area, number of air conditioner per household and building function were obviously correlated with energy consumption;income, building shape factor and window to wall area ratio had no correlation with energy consumption in the low energy consumption area.