DISTRIBUTING ENERGY AS NEEDED A system anchored with clean energy could be an effective way to achieve green low-carbon energy transformation
1
作者 Song Xiaohua Zhang Lu +1 位作者 Lu Jiayu Su Yujing 《China Report ASEAN》 2021年第8期38-41,共4页
China has a big demand for energy but limited energy resources.To achieve green and low-carbon development,it must accelerate construction of a distributed energy system(DES)with high energy utilization efficiency and... China has a big demand for energy but limited energy resources.To achieve green and low-carbon development,it must accelerate construction of a distributed energy system(DES)with high energy utilization efficiency and low environmental pollution,which will be a tremendously significant step towards the country’s goals of peaking carbon emissions by 2030 and achieving carbon neutrality by 2060(the“3060”target). 展开更多
关键词 system carbon ENERGY
下载PDF
A Disturbance Source Location Method on the Low Frequency Oscillation With Time-varying Steady-state Points
2
作者 Xiangxin Li Ming Zhou Yazhou Luo 《CES Transactions on Electrical Machines and Systems》 2018年第2期226-231,共6页
The low frequency oscillation is a serious threat to security and stability of a power grid.How to locate the disturbance source accurately is an important issue to low frequency oscillation disposal.Existing methods ... The low frequency oscillation is a serious threat to security and stability of a power grid.How to locate the disturbance source accurately is an important issue to low frequency oscillation disposal.Existing methods have poor adaptability to the low frequency oscillation with time-varying steady-state points because of the limitations in the location criterion derivation.A disturbance source location method on a low frequency oscillation with good generality is presented in the paper.Firstly,the reasons why the steady-state points are time-varying on a low frequency oscillation are analyzed.Then,based on the energy function construction form,the branch transmission energy is decomposed into state energy,reciprocating energy and dissipation energy by mathematical derivation.The flow direction of the dissipation energy shows the source and destination of the disturbance energy,and the specific location of a disturbance source can be identified according to its flow direction.Meanwhile,to meet the needs of energy calculation,a recognition method on the electrical quantities steady-state points is also presented by using the cubic spline interpolation.Simulation results show the correctness of the derivation and analysis on energy structure in the paper,and the disturbance source can be located accurately according to the dissipation energy. 展开更多
关键词 dissipation energy disturbance source location energy decomposition low frequency oscillation steady-state point identification
下载PDF
Effective Ultra-High-Speed Identification Scheme of Lightning Strikes Suitable for VSC-Based DC Grids 被引量:1
3
作者 Longlong Chen Xiangyu Pei +2 位作者 Xiaoguang Wei Pengzhi Li Guangfu Tang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期548-561,共14页
To ensure their sound and continuous operation to the greatest extent,VSC-based DC girds have extremely stringent requirements for transmission line relay protection.In terms of guaranteeing their reliability,accurate... To ensure their sound and continuous operation to the greatest extent,VSC-based DC girds have extremely stringent requirements for transmission line relay protection.In terms of guaranteeing their reliability,accurate identification of lightning strikes on DC transmission lines is one of the urgent key problems to be solved.An effective ultra-high-speed identification scheme of lightning strikes suitable for the VSC-based DC grid is proposed in this paper.First,an 1-mode reverse voltage traveling wave(RVTW)is constructed applying the pole-mode transformation theory.Next,fault traveling wave propagation characteristics along the DC transmission line are analyzed in depth utilizing Peterson's law.Then,differences of time-frequency electromagnetic transient characteristics of 1-mode RVTWs between disturbances and faults caused by lightning strikes are distinguished in detail by means of the classical wavelet transformation multi-resolution analysis theory.Finally,extensive simulations are carried out to evaluate the performance of the proposed identification scheme,and by which its excellent rapidity,reliability and robustness are validated.Index Terms-Lightning-strike identification,Multi-resolution analysis,Relay protection,Traveling-wave protection,VsC-based DC grid,Wavelet transformation. 展开更多
关键词 Lightning-strike identification Multi-resolution analysis Relay protection Traveling-wave protection VsC-based DC grid Wavelet transformation
原文传递
Currentless Multiple Switch Open-Circuit Faults Diagnosis for Modular Multilevel Converters with Nearest Level Modulation in HVDC Systems
4
作者 Zhi Geng Minxiao Han +1 位作者 Changjiang Xia Longze Kou 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第4期1642-1653,共12页
Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a ... Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a challenge for the fault diagnosis strategy(FDS).This paper proposes a currentless FDS for MMC with NLM.In FDS,the voltage sensor is relocated to measure the output voltage of the SM.To acquire the capacitor voltage and avoid increasing extra sensors,a capacitor voltage calculation method is proposed.Based on the measurement of output voltages,the faults can be detected and the number of different-type switch open-circuit faults can be confirmed from the numerous SMs in an arm,which narrows the scope of fault localization.Then,the faulty SMs and faulty switches in these SMs are further located without arm current according to the sorting of capacitor voltages in the voltage balancing algorithm.The FDS is independent of the arm current,which can reduce the communication cost in the hierarchical control system of MMC.Furthermore,the proposed FDS not only simplifies the identification of switch open-circuit faults by confirming the scope of faults,but also detects and locates multiple different-type faults in an arm.The effectiveness of the proposed strategy is verified by the simulation results. 展开更多
关键词 Fault diagnosis high voltage direct current(HVDC) modular multilevel converter(MMC) nearest level modulation(NLM) switch open-circuit fault
原文传递
An optimized short-term wind power interval prediction method considering NWP accuracy 被引量:4
5
作者 Yongqian Liu Jie Yan +3 位作者 Shuang Han Infield David De Tian Linyue Gao 《Chinese Science Bulletin》 SCIE EI CAS 2014年第11期1167-1175,共9页
In recent years, the accuracy of the wind power prediction has been urgently studied and improved to satisfy the requirements of power system operation. In this paper, the relevance vector machine(RVM)-based models ar... In recent years, the accuracy of the wind power prediction has been urgently studied and improved to satisfy the requirements of power system operation. In this paper, the relevance vector machine(RVM)-based models are established to predict the wind power and its interval for a given confidence level. An NWP improvement module is presented considering the characteristic of NWP error. Moreover, two parameter optimization algorithms are applied to further improve the prediction model and to compare each performance. To take three wind farms in China as examples, the performance of two RVM-based models optimized, respectively, by genetic algorithm(GA)and particle swarm optimization(PSO) are compared with predictions based on a genetic algorithm–artificial neural network(GA–ANN) and support vector machine. Results show that the proposed models have better prediction accuracy with GA–RVM model and more efficient calculation with PSO–RVM. 展开更多
关键词 参数优化算法 区间预测 预测精度 风电场 预测模型 支持向量机 短期 电力系统运行
原文传递
Integrated Equivalent Model of Permanent Magnet Synchronous Generator Based Wind Turbine for Large-scale Offshore Wind Farm Simulation 被引量:1
6
作者 Ming Zou Yan Wang +3 位作者 Chengyong Zhao Jianzhong Xu Xiaojiang Guo Xu Sun 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第5期1415-1426,共12页
The high-speed simulation of large-scale offshore wind farms(OWFs) preserving the internal machine information has become a huge challenge due to the large wind turbine(WT) count and microsecond-range time step. Hence... The high-speed simulation of large-scale offshore wind farms(OWFs) preserving the internal machine information has become a huge challenge due to the large wind turbine(WT) count and microsecond-range time step. Hence, it is undoable to investigate the internal node information of the OWF in the electro-magnetic transient(EMT) programs. To fill this gap,this paper presents an equivalent modeling method for largescale OWF, whose accuracy and efficiency are guaranteed by integrating the individual devices of permanent magnet synchronous generator(PMSG) based WT. The node-elimination algorithm is used while the internal machine information is recursively updated. Unlike the existing aggregation methods, the developed EMT model can reflect the characteristics of each WT under different wind speeds and WT parameters without modifying the codes. The access to each WT controller is preserved so that the time-varying dynamics of all the WTs could be simulated. Comparisons of the proposed model with the detailed model in PSCAD/EMTDC have shown very high precision and high efficiency. The proposed modeling procedures can be used as reference for other types of WTs once the structures and parameters are given. 展开更多
关键词 Offshore wind farm(OWF) electro-magnetic transient(EMT) integrated equivalent modelling permanent magnet synchronous generator(PMSG)based wind turbine(WT)
原文传递
Hybrid MMC with Low Voltage Operations and DC Fault Ride-through Capabilities Based on Auxiliary Full-bridge Converter 被引量:4
7
作者 Xibei Zhao Jiangping Ding +1 位作者 Jianzhong Xu Jinsha Yuan 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2022年第3期864-871,共8页
The hybrid modular multilevel converter(MMC)based on half-bridge sub-modules(HBSMs)and full-bridge submodules(FBSMs)can operate at low DC voltages and clear DC side fault currents.However,the costs and power losses ar... The hybrid modular multilevel converter(MMC)based on half-bridge sub-modules(HBSMs)and full-bridge submodules(FBSMs)can operate at low DC voltages and clear DC side fault currents.However,the costs and power losses are much higher in hybrid converters.An auxiliary full-bridge converter(AFC)is designed to reconstruct the converter structure in the arm level,and the HBSMs output capacitor voltage through the AFC can attain similar capabilities to hybrid MMCs.The operational principle of the auxiliary full-bridge converter is discussed,and the low voltage operation and non-blocking fault ride through control are verified in a two-terminal DC network simulation.Through economic analysis,the power loss of the AFC is similar to a HBSM MMC but the total investment is lower than a hybrid MMC,making the AFC a promising solution to improve the existing HBSM converter with more controllability. 展开更多
关键词 DC fault fault ride through hybrid MMC low voltage operation
原文传递