Objective:To report our experience with the hybrid external fixator in emergency.Methods:We assessed 80 cases of pilon fracture treated with the external fixator during the period of January 2009 and December 2016:55 ...Objective:To report our experience with the hybrid external fixator in emergency.Methods:We assessed 80 cases of pilon fracture treated with the external fixator during the period of January 2009 and December 2016:55 men (69%) and 30 women (33%) with a mean age of 40 years (range between 16 and 70 ). About 45 occurred as isolated trauma, 35 instead were politrauma. Each patient underwent standard radiographic examination and a CT examination. There were 28 open fractures (35%), (Gustilo type 1, 2 and 3) while closed fractures showed soft tissue involvement of various grade (2-3 Tscherne classification). In all cases, the external fixation, sometimes associated with other reduction and synthesis techniques, was used. The timing of surgery was dictated by the condition of the soft tissues. For clinical evaluation, the Mazur score with mean follow-ups at 12 months was utilized.Results:The final range of ankle motion was 15 dorsal and 10 plantar flexion. In about 80 cases there was an average Mazur score of83. The mean score was 90;in open fractures 85 to 72. Radiographic healing of fractures in 60 patients occurred in 120 days (mean 105 days), at the time when the external fixator was removed.Conclusion:Pilon fractures are complex and often present complications;the definitive treatment, in emergency or delayed, with hybrid external fixator permits a stable synthesis with minimal soft tissue damage. Weight bearing maybe allowed early and functional recovery is generally good.展开更多
Although the rate of patients reporting satisfaction is generally high after joint replacement surgery, up to 23% after total hip replacement and 34% after total knee arthroplasty of treated subjects report discomfort...Although the rate of patients reporting satisfaction is generally high after joint replacement surgery, up to 23% after total hip replacement and 34% after total knee arthroplasty of treated subjects report discomfort or pain 1 year after surgery. Moreover, chronic or subacute inflammation is reported in some cases even a long time after surgery. Another open and debated issue in prosthetic surgery is implant survivorship, especially when related to good prosthesis bone ingrowth. Pulsed Electro Magnetic Fields(PEMFs) treatment, although initially recommended after total joint replacement to promote bone ingrowth and to reduce inflammation and pain, is not currently part of usual clinical practice. The purpose of this review was to analyze existing literature on PEMFs effects in joint replacement surgery and to report results of clinical studies and current indications. We selected all currently available prospective studies or RCT on the use of PEMFs in total joint replacement with the purpose of investigating effects of PEMFs on recovery, pain relief and patients’ satisfaction following hip, knee or shoulder arthroplasty. All the studies analyzed reported no adverse effects, and good patient compliance to the treatment. The available literature shows that early control of joint inflammation process in the first days after surgery through the use of PEMFs should be considered an effective completion of the surgical procedure to improve the patient’s functional recovery.展开更多
文摘Objective:To report our experience with the hybrid external fixator in emergency.Methods:We assessed 80 cases of pilon fracture treated with the external fixator during the period of January 2009 and December 2016:55 men (69%) and 30 women (33%) with a mean age of 40 years (range between 16 and 70 ). About 45 occurred as isolated trauma, 35 instead were politrauma. Each patient underwent standard radiographic examination and a CT examination. There were 28 open fractures (35%), (Gustilo type 1, 2 and 3) while closed fractures showed soft tissue involvement of various grade (2-3 Tscherne classification). In all cases, the external fixation, sometimes associated with other reduction and synthesis techniques, was used. The timing of surgery was dictated by the condition of the soft tissues. For clinical evaluation, the Mazur score with mean follow-ups at 12 months was utilized.Results:The final range of ankle motion was 15 dorsal and 10 plantar flexion. In about 80 cases there was an average Mazur score of83. The mean score was 90;in open fractures 85 to 72. Radiographic healing of fractures in 60 patients occurred in 120 days (mean 105 days), at the time when the external fixator was removed.Conclusion:Pilon fractures are complex and often present complications;the definitive treatment, in emergency or delayed, with hybrid external fixator permits a stable synthesis with minimal soft tissue damage. Weight bearing maybe allowed early and functional recovery is generally good.
文摘Although the rate of patients reporting satisfaction is generally high after joint replacement surgery, up to 23% after total hip replacement and 34% after total knee arthroplasty of treated subjects report discomfort or pain 1 year after surgery. Moreover, chronic or subacute inflammation is reported in some cases even a long time after surgery. Another open and debated issue in prosthetic surgery is implant survivorship, especially when related to good prosthesis bone ingrowth. Pulsed Electro Magnetic Fields(PEMFs) treatment, although initially recommended after total joint replacement to promote bone ingrowth and to reduce inflammation and pain, is not currently part of usual clinical practice. The purpose of this review was to analyze existing literature on PEMFs effects in joint replacement surgery and to report results of clinical studies and current indications. We selected all currently available prospective studies or RCT on the use of PEMFs in total joint replacement with the purpose of investigating effects of PEMFs on recovery, pain relief and patients’ satisfaction following hip, knee or shoulder arthroplasty. All the studies analyzed reported no adverse effects, and good patient compliance to the treatment. The available literature shows that early control of joint inflammation process in the first days after surgery through the use of PEMFs should be considered an effective completion of the surgical procedure to improve the patient’s functional recovery.