期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Background correction in near-infrared spectra of plant extracts by orthogonal signal correction 被引量:1
1
作者 瞿海斌 欧丹林 程翼宇 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE EI CAS CSCD 2005年第8期838-843,共6页
In near-infrared (NIR) analysis of plant extracts, excessive background often exists in near-infrared spectra. The detection of active constituents is difficult because of excessive background, and correction of this ... In near-infrared (NIR) analysis of plant extracts, excessive background often exists in near-infrared spectra. The detection of active constituents is difficult because of excessive background, and correction of this problem remains difficult. In this work, the orthogonal signal correction (OSC) method was used to correct excessive background. The method was also compared with several classical background correction methods, such as offset correction, multiplicative scatter correction (MSC), standard normal variate (SNV) transformation, de-trending (DT), first derivative, second derivative and wavelet methods. A simulated dataset and a real NIR spectral dataset were used to test the efficiency of different background correction methods. The results showed that OSC is the only effective method for correcting excessive background. 展开更多
关键词 Background correction Plant extracts Orthogonal signal correction Near-infrared spectroscopy
下载PDF
Wavelet-based classification and influence matrix analysis method for the fast discrimination of Chinese herbal medicines according to the geographical origins with near infrared spectroscopy 被引量:1
2
作者 Wenlong Li Haibin Qu 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2014年第4期21-31,共11页
A discriminant analysis technique using wavelet transformation(WT)and influence matrixanalysis(CAIMAN)method is proposed for the near infrared(NIR)spectroscopy classifi-cation.In the proposed methodology,NIR spectra a... A discriminant analysis technique using wavelet transformation(WT)and influence matrixanalysis(CAIMAN)method is proposed for the near infrared(NIR)spectroscopy classifi-cation.In the proposed methodology,NIR spectra are decomposed by WT for data com-pression and a forward feature selection is further employed to extract the relevant informationfrom the wavelet coefficients,reducing both classification errors and model complexity.Adiscriminant-CAIMAN(D-CAIMAN)method is utilized to build the classification model inwavelet domain on the basis of reduced wavelet coefficients of spectral variables.NIR spectradata set of 265 salviae miltiorrhizae radia samples from 9 different geographical origins is usedas an example to test the classification performance of the algorithm.For a comparison,k-nearest neighbor(KNN),linear discriminant analysis(LDA)and quadratic discriminant analysis(QDA)methods are also employed.D-CAIMAN with wavelet-based feature selection(WD-CAIMAN)method shows the best performance,achieving the total classification rate of ioo%in both cross-validation set and prediction set.It is worth noting that the WD-CAIMANclassifier also shows improved sensitivity,selectivity and model interpretability in thecla.ssifications. 展开更多
关键词 Discriminant analysis near infrared spectroscopy Chinese herbal medicines variable selection wavelet analysis
下载PDF
Simultaneous LC-MS/MS Determination of Danshensu and Paeoniflorin for Permeability Studies in Caco-2 Intestinal Absorption Model 被引量:1
3
作者 LIU Li ZHAO Xiao-ping +2 位作者 ZHU Di-feng CHENG Yi-yu QU Hai-bin 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2008年第4期420-426,共7页
A high sensitive method based on liquid chromatography tandem mass spectrometry(LC-MS/MS) was developed and validated for the study of permeability of danshensu(DS) and paeoniflorin(PF) in Caco-2 intestinal abso... A high sensitive method based on liquid chromatography tandem mass spectrometry(LC-MS/MS) was developed and validated for the study of permeability of danshensu(DS) and paeoniflorin(PF) in Caco-2 intestinal absorption model. The DS and PF were extracted from cell culture by vacuum-lyophilizing and then separated on a Zorbax Stable Bond C18 column with 0.1% acetic acid aqueous solution and methanol as mobile phase. Detection was carried out by negative electrospray ionization(ESI ) with selected reaction monitoring(SRM) mode. The apparent permeability coefficients(Papp) of DS and PF in Caco-2 cell medium were calculated and the effects of verapamil on the coefficients Papp of the two test compounds were also illustrated. The permeability of PF was much better than that of DS when the two compounds were administrated individually. Co-administration of DS and PF led to the decrease of the transport from apical side to basolateral side for both the compounds. However, the transport in the contrary direction were accelerated. It was also observed that verapamil could accelerate the transport of the test compounds from apical side to basolateral side. However, the absorption-enhanced effect of verapamil was attenuated when DS and PF were co-administrated. These observations suggest that both passive diffusion and active efflux involved in P-gp would effect the passage of DS and PF across Caco-2 cell monolayer. At the same time, the co-administration of DS and PF to an alteration of transport behavior, which suggests that the interaction must be taken into account when ‘n-in-one' samples were used in Caco-2 intestinal model. 展开更多
关键词 Denshensu PAEONIFLORIN Caco-2 cell Apparent permeability coefficient LC-MS/MS
下载PDF
Characterization of herbal powder blends homogeneity using near-infrared spectroscopy
4
作者 Wenlong Li Haibin Qu 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2014年第6期33-39,共7页
Homogeneity of powder blend is essential to obtain uniform contents for the tablets and capsules.Near-infrared(NIR)spectroscopy with fiber-optic probe was used as an on-line technique for monitoring the homogeneity of... Homogeneity of powder blend is essential to obtain uniform contents for the tablets and capsules.Near-infrared(NIR)spectroscopy with fiber-optic probe was used as an on-line technique for monitoring the homogeneity of pharmaceutical blend during the blending process instead of the traditional techniques,such as high performance liquid chromatograph(HPLC)method.In this paper NIRS with a SabIR difuse reflectance fiber optic probe was used to monitor the blending process of coptis powder and lactose(excipient)with different contents,and further qualitative methods,like similarity,moving block of standard deviation and mean square were used for calculation purposes with the ollected spectra after the pretreatment of multiplicative signal correction(MSC)and second derivative.Correlation spectrum was used for the wavelength selection.Four different coptis were blended with lactose separately to validate the proposed method,and the blending process of "liu wei di huang"pill was also simulated in bottles to verify this method on multiple herbal blends.The overall results suggest that NIRS is a simple,efective and noninvasive technique can be sucssfuly applied to the determination of homogeneity in the herbal blend. 展开更多
关键词 Near infrared spect roscopy traditional Chinese medicine powder blend homnogeneity
下载PDF
In-situ monitoring of saccharides removal of alcohol precipitation using near-infrared spectroscopy
5
作者 Hongxia Huang Haibin Qu 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2018年第5期30-41,共12页
As unsafe components in herbal medicine(HM),saccharides can affect not only the drug appearance and stabilization,but also the drug efficacy and safety.The present study focuses on the in-line monitoring of batch alco... As unsafe components in herbal medicine(HM),saccharides can affect not only the drug appearance and stabilization,but also the drug efficacy and safety.The present study focuses on the in-line monitoring of batch alcohol precipitation processes for saccharide removal using nearinfrared(NIR)spectroscopy.NIR spectra in the 4000–10,000-cm^(-1)wavelength range are acquired in situ using a transflectance probe.These directly acquired spectra allow characterization of the dynamic variation tendency of saccharides during alcohol precipitation.Calibration models based on partial least squares(PLS)regression have been developed for the three saccharide impurities,namely glucose,fructose,and sucrose.Model errors are estimated as the root-meansquare errors of cross-validation(RMSECVs)of internal validation and root-mean-square errors of prediction(RMSEPs)of external validation.The RMSECV values of glucose,fructose,and sucrose were 1.150,1.535,and 3.067 mg·mL^(-1),and the RMSEP values were 0.711,1.547,and 3.740 mg·mL^(-1),respectively.The correlation coeffcients(r)between the NIR predictive and the reference measurement values were all above 0.94.Furthermore,NIR predictions based on the constructed models improved our understanding of sugar removal and helped develop a control strategy for alcohol precipitation.The results demonstrate that,as an alternative process analytical technology(PAT)tool for monitoring batch alcohol precipitation processes,NIR spectroscopy is advantageous for both efficient determination of quality characteristics(fast,in situ,and requiring no toxic reagents)and process stability,and evaluating the repeatability. 展开更多
关键词 Herbal medicine alcohol precipitation near-infrared spectroscopy saccharides removal process analytical technology
下载PDF
Screening and identification of multiple components in Tanreqing injection using RP-HPLC combined with DAD and ESI-TOF/MS 被引量:9
6
作者 LIU Shao-Yong XUE Dong-Sheng +3 位作者 PAN Jian-Chao ZHANG Wen-Ming LI Wen-Long QU Hai-Bin 《Chinese Journal of Natural Medicines》 SCIE CAS CSCD 2014年第7期535-541,共7页
A liquid chromatography coupled with diode array detector(DAD) and electrospray ionization time-of-flight mass spectrometry(ESI-TOF/MS) method was developed for the screening and identification of the multiple compone... A liquid chromatography coupled with diode array detector(DAD) and electrospray ionization time-of-flight mass spectrometry(ESI-TOF/MS) method was developed for the screening and identification of the multiple components in Tanreqing injection, a well-known Chinese medicine injection in China. By combining the DAD spectrum and the accurate mass measurement of ESI-TOF/MS, twelve components in Tanreqing injection were identified. This study contributes to clarifying the nature of Tanreqing injection, and provides an effective and reliable process for the comprehensive and systematic characterization of complex traditional Chinese medicine preparations. 展开更多
关键词 Tanreqing injection Screening and identification DAD ESI-TOF/MS
原文传递
Manufacturer identification and storage time determination of “Dong'e Ejiao” using near infrared spectroscopy and chemometrics 被引量:5
7
作者 Wen-long LI Hai-fan HAN +2 位作者 Lu ZHANG Yan ZHANG Hai-bin QU 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2016年第5期382-390,共9页
We have developed a set of chemometric methods to address two critical issues in quality control of a precious traditional Chinese medicine (TCM), Dong'e Ejiao (DEE J). Based on near infrared (NIR) spectra of m... We have developed a set of chemometric methods to address two critical issues in quality control of a precious traditional Chinese medicine (TCM), Dong'e Ejiao (DEE J). Based on near infrared (NIR) spectra of multiple samples, the genuine manufacturer of DEE J, e.g. Dong'e Ejiao Co., Ltd., was accurately identified among 21 suppliers by the fingerprint method using Hotelling T2, distance to Model X (DModX), and similarity match value (SMV) as dis- criminate criteria. Soft independent modeling of the class analogy algorithm led to a misjudgment ratio of 6.2%, suggesting that the fingerprint method is more suitable for manufacturer identification. For another important feature related to clinical efficacy of DEE J, storage time, the partial least squares-discriminant analysis (PLS-DA) method was applied with a satisfactory misjudgment ratio (15.6%) and individual prediction error around 1 year. Our results demonstrate that NIR spectra comprehensively reflect the essential quality information of DEE J, and with the aid of proper chemometric algorithms, it is able to identify genuine manufacturer and determine accurate storage time. The overall results indicate the promising potential of NIR spectroscopy as an effective quality control tool for DEEJ and other precious TCM products. 展开更多
关键词 Dong'e Ejiao Near infrared spectroscopy Manufacturer identification Storage time identification Quality control
原文传递
An approach to optimize the batch mixing process for improving the quality consistency of the products made from traditional Chinese medicines 被引量:2
8
作者 Bin-jun YAN Hai-bin QU 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2013年第11期1041-1048,共8页
The efficacy of traditional Chinese medicine(TCM)is based on the combined effects of its constituents.Variation in chemical composition between batches of TCM has always been the deterring factor in achieving consiste... The efficacy of traditional Chinese medicine(TCM)is based on the combined effects of its constituents.Variation in chemical composition between batches of TCM has always been the deterring factor in achieving consistency in efficacy.The batch mixing process can significantly reduce the batch-to-batch quality variation in TCM extracts by mixing them in a well-designed proportion.However,reducing the quality variation without sacrificing too much of the production efficiency is one of the challenges.Accordingly,an innovative and practical batch mixing method aimed at providing acceptable efficiency for industrial production of TCM products is proposed in this work,which uses a minimum number of batches of extracts to meet the content limits.The important factors affecting the utilization ratio of the extracts(URE)were studied by simulations.The results have shown that URE was affected by the correlation between the contents of constituents,and URE decreased with the increase in the number of targets and the relative standard deviations of the contents.URE could be increased by increasing the number of storage tanks.The results have provided a reference for designing the batch mixing process.The proposed method has possible application value in reducing the quality variation in TCM and providing acceptable production efficiency simultaneously. 展开更多
关键词 Batch-to-batch quality consistency Batch mixing Production efficiency Traditional Chinese medicine
原文传递
Optimization of micellar electrokinetic capillary chromatography method using central composite design for the analysis of components in Yangwei granule 被引量:1
9
作者 Shu-fang WANG Hai-yan FANG Hai-bin QU 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2011年第3期193-200,共8页
Central composite design(CCD),together with multiple linear regression,was successfully used to optimize the electrophoretic buffer system of micellar electrokinetic capillary chromatography(MEKC) for the determinatio... Central composite design(CCD),together with multiple linear regression,was successfully used to optimize the electrophoretic buffer system of micellar electrokinetic capillary chromatography(MEKC) for the determination of albiflorin,paeoniflorin,liquiritin,and glycyrrhizic acid in the traditional Chinese medicine(TCM) prescription,Yangwei granule.Concentrations of sodium deoxycholate(SDC) and borate,and proportions of ammonia,acetonitrile,and methanol were optimized.The total resolutions of peaks between the analytes and their adjacent peaks in real samples were integrated into the evaluation index of separation efficiency.The optimum electrophoretic buffer contained 80 mmol/L SDC,20 mmol/L borate,5%(v/v) methanol,0.5%(v/v) ammonia,and 5%(v/v) acetonitrile.The correlation coefficients(R 2 ) between the peak areas and the corresponding concentrations of analytes were greater than 0.9956.The limits of detection(LODs) (S/N=3) of the analytes were 0.97-4.00μg/ml.The results indicate the superiority of CCD in optimizing the separation conditions of complex samples such as TCM prescriptions. 展开更多
关键词 Micellar electrokinetic capillary chromatography Traditional Chinese medicine Central composite design Yangwei granule
原文传递
Rapid quantification of multi-components in alcohol precipitation liquid of Codonopsis Radix using near infrared spectroscopy(NIRS) 被引量:1
10
作者 Yu LUO Wen-long LI +3 位作者 Wen-hua HUANG Xue-hua LIU Yan-gang SONG Hai-bin QU 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2017年第5期383-392,共10页
A near infrared spectroscopy(NIRS) approach was established for quality control of the alcohol precipitation liquid in the manufacture of Codonopsis Radix. By applying NIRS with multivariate analysis, it was possibl... A near infrared spectroscopy(NIRS) approach was established for quality control of the alcohol precipitation liquid in the manufacture of Codonopsis Radix. By applying NIRS with multivariate analysis, it was possible to build variation into the calibration sample set, and the Plackett-Burman design, Box-Behnken design, and a concentrating-diluting method were used to obtain the sample set covered with sufficient fluctuation of process parameters and extended concentration information. NIR data were calibrated to predict the four quality indicators using partial least squares regression(PLSR). In the four calibration models, the root mean squares errors of prediction(RMSEPs) were 1.22 μg/ml, 10.5 μg/ml, 1.43 μg/ml, and 0.433% for lobetyolin, total flavonoids, pigments, and total solid contents, respectively. The results indicated that multi-components quantification of the alcohol precipitation liquid of Codonopsis Radix could be achieved with an NIRS-based method, which offers a useful tool for real-time release testing(RTRT) of intermediates in the manufacture of Codonopsis Radix. 展开更多
关键词 Near infrared spectroscopy Codonopsis Radix Alcohol precipitation Real-time release testing Multicomponents quantification
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部