With the increasing penetration of renewable energy in power system,renewable energy power ramp events(REPREs),dominated by wind power and photovoltaic power,pose significant threats to the secure and stable operation...With the increasing penetration of renewable energy in power system,renewable energy power ramp events(REPREs),dominated by wind power and photovoltaic power,pose significant threats to the secure and stable operation of power systems.This paper presents an early warning method for REPREs based on long short-term memory(LSTM)network and fuzzy logic.First,the warning levels of REPREs are defined by assessing the control costs of various power control measures.Then,the next 4-h power support capability of external grid is estimated by a tie line power predictionmodel,which is constructed based on the LSTMnetwork.Finally,considering the risk attitudes of dispatchers,fuzzy rules are employed to address the boundary value attribution of the early warning interval,improving the rationality of power ramp event early warning.Simulation results demonstrate that the proposed method can generate reasonable early warning levels for REPREs,guiding decision-making for control strategy.展开更多
The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-...The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-wire system.However,as the zero-sequence voltage is expressed in trigonometric form,traditional control methods involve many complicated operations,such as the square-root,trigonometric operations,and inverse tangent operations.To simplify cluster voltage balancing control,this paper converts the zero-sequence voltage to the dq frame in a DC representation by introducing a virtually orthogonal variable,and the DC components of the zero-sequence voltage in the dq frame are regulated linearly by proportional integral regulators,rather than being calculated from uneven active powers in traditional controls.This removes all complicated operations.Finally,this paper presents simulation and experimental results for a 400 V±7.5 kvar star-connected STATCOM,in balanced and unbalanced scenarios,thereby verifying the effectiveness of the proposed control.展开更多
基金funded by State Grid Shandong Electric Power Company Technology Project(520626220110).
文摘With the increasing penetration of renewable energy in power system,renewable energy power ramp events(REPREs),dominated by wind power and photovoltaic power,pose significant threats to the secure and stable operation of power systems.This paper presents an early warning method for REPREs based on long short-term memory(LSTM)network and fuzzy logic.First,the warning levels of REPREs are defined by assessing the control costs of various power control measures.Then,the next 4-h power support capability of external grid is estimated by a tie line power predictionmodel,which is constructed based on the LSTMnetwork.Finally,considering the risk attitudes of dispatchers,fuzzy rules are employed to address the boundary value attribution of the early warning interval,improving the rationality of power ramp event early warning.Simulation results demonstrate that the proposed method can generate reasonable early warning levels for REPREs,guiding decision-making for control strategy.
基金supported by National Key R&D Program of China(No.2021YFB2401100)the Science and Technology Project of State Grid Corporation of China(No.5211DS22002C).
文摘The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-wire system.However,as the zero-sequence voltage is expressed in trigonometric form,traditional control methods involve many complicated operations,such as the square-root,trigonometric operations,and inverse tangent operations.To simplify cluster voltage balancing control,this paper converts the zero-sequence voltage to the dq frame in a DC representation by introducing a virtually orthogonal variable,and the DC components of the zero-sequence voltage in the dq frame are regulated linearly by proportional integral regulators,rather than being calculated from uneven active powers in traditional controls.This removes all complicated operations.Finally,this paper presents simulation and experimental results for a 400 V±7.5 kvar star-connected STATCOM,in balanced and unbalanced scenarios,thereby verifying the effectiveness of the proposed control.