期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Field study results of a 3rd generation roof bolter canopy air curtain for respirable coal mine dust control 被引量:4
1
作者 W.R.Reed M.Shahan +4 位作者 S.Klima G.Ross K.Singh R.Cross T.Grounds 《International Journal of Coal Science & Technology》 EI 2020年第1期79-87,共9页
A 3rd generation roof bolter canopy air curtain(CAC)has been developed and constructed by J.H.Fletcher&Co.,Inc.As with the previous generation of the CAC,this design uses the principle of providing uniform airflow... A 3rd generation roof bolter canopy air curtain(CAC)has been developed and constructed by J.H.Fletcher&Co.,Inc.As with the previous generation of the CAC,this design uses the principle of providing uniform airflow across the canopy area as recommended by the National Institute for Occupational Safety and Health.The new modifications include a plenum that is constructed of a single flat aluminum plate,smaller-diameter airflow openings,and a single row of perimeter nozzles designed to prevent mine air contaminated by respirable dust from entering the CAC protection zone.Field testing was conducted on this new 3rd generation design showing reductions in coal mine respirable dust exposure for roof bolter operators.Dust control efficiencies for the CAC for the left bolter operator(intake side)ranged from approximately 26%–60%,while the efficiencies for the CAC for the right bolter operator(return side)ranged from 3%to 47%. 展开更多
关键词 Roof bolter Respirable dust Coal mining Canopy air curtain
下载PDF
A field study of a roof bolter canopy air curtain(2nd generation)for respirable coal mine dust control 被引量:2
2
作者 W.R.Reed S.Klima +4 位作者 M.Shahan G.J.H.Ross K.Singh R.Cross T.Grounds 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2019年第5期711-720,共10页
A 2nd generation roof bolter canopy air curtain(CAC)design was tested by National Institute for Occupational Safety and Health(NIOSH)at a Midwestern underground coal mine.During the study,the roof bolter never operate... A 2nd generation roof bolter canopy air curtain(CAC)design was tested by National Institute for Occupational Safety and Health(NIOSH)at a Midwestern underground coal mine.During the study,the roof bolter never operated downwind of the continuous miner.Using a combination of personal Data Rams(pDR)and gravimetric samplers,the dust control efficiency of the roof bolter CAC was ascertained.Performance evaluation was determined using three methods:(1)comparing roof bolter operator concentrations underneath the CAC to roof bolter concentrations outside the CAC,(2)comparing roof bolter operator concentrations underneath the CAC to the concentrations at the rear of the bolter,and finally,(3)using the gravimetric data directly underneath the CAC to correct roof bolter operator concentrations underneath the CAC and comparing them to the concentrations at the rear of the bolter.Method 1 dust control efficiencies ranged from 53.9%to 60.4%.Method 2 efficiencies ranged from 150.5%to 52.2%,and Method 3 efficiencies ranged from 40.7%to 91%.Reasons for negative and low dust control efficiencies are provided in this paper and include:incorrect sampling locations,large distance between CAC and operator,and contamination of intake air from line curtain.Low dust concentrations encountered during the testing made it difficult to discern whether differences in concentrations were due to the CAC or due to variances inherent in experimental dust measurement.However,the analyses,especially the Method 3 analysis,show that the CAC can be an effective dust control device. 展开更多
关键词 COAL ROOF bolter Respirable DUST UNDERGROUND mining
下载PDF
上一页 1 下一页 到第