期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Comparative Study of Micro and Nano Size WO3/E44 Epoxy Composite as Gamma Radiation Shielding Using MCNP and Experiment 被引量:1
1
作者 Shahryar Malekie Nahid Hajiloo 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第10期92-94,共3页
The radiation shielding characteristics of 50wt% WO3/E44 epoxy composite in various gamma energies from 80 keV to 1.33 MeV are investigated via the MCNP code. Thus two scales are considered for WOa filler particles: ... The radiation shielding characteristics of 50wt% WO3/E44 epoxy composite in various gamma energies from 80 keV to 1.33 MeV are investigated via the MCNP code. Thus two scales are considered for WOa filler particles: micro and nano with sizes of i #m and 5Onto, respectively. The simulation results show that W03 nano particles exhibit a larger increase in linear attenuation coefficient in comparison with micro size particles. Finally, validation of simulation results with the published experimental data shows a good agreement. 展开更多
关键词 Comparative Study of Micro and Nano Size WO3/E44 Epoxy Composite as Gamma Radiation Shielding Using MCNP and Experiment
下载PDF
Calculation of thermal neutron albedo for mono-material and bi-material reflectors 被引量:1
2
作者 Sara Azimkhani Farhad Zolfagharpour Farhood Ziaie 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第9期185-191,共7页
Thermal neutron albedo has been investigated for different thicknesses of mono-material and bi-material reflectors. An equation has been obtained for a bi-material reflector by considering the neutron diffusion equati... Thermal neutron albedo has been investigated for different thicknesses of mono-material and bi-material reflectors. An equation has been obtained for a bi-material reflector by considering the neutron diffusion equation. The bi-material reflector consists of binary combinations of water, graphite, lead, and polyethylene. An experimental measurement of thermal neutron albedo has also been conducted for mono-material and bi-material reflectors by using a^(241) Am–Be(5.2 Ci) neutron source and a BF3 detector. The maximum value of thermal neutron albedo was obtained for a polyethylene–water combination(0.95 ± 0.02). 展开更多
关键词 NEUTRON current BI-MATERIAL REFLECTOR Thermal NEUTRON ALBEDO BF3 detector Reflection Diffusion equation
下载PDF
Determination of water equivalent ratio for some dosimetric materials in proton therapy using MNCPX simulation tool 被引量:1
3
作者 Reza Bagheri Alireza Khorrami Moghaddam +2 位作者 Bakhtiar Azadbakht Mahmoud Reza Akbari Seyed Pezhman Shirmardi 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第2期19-28,共10页
The water equivalent ratio(WER) was calculated for polypropylene(PP), paraffin, polyethylene(PE), polystyrene(PS), polymethyl methacrylate(PMMA), and polycarbonate materials with potential applications in dosimetry an... The water equivalent ratio(WER) was calculated for polypropylene(PP), paraffin, polyethylene(PE), polystyrene(PS), polymethyl methacrylate(PMMA), and polycarbonate materials with potential applications in dosimetry and medical physics. This was performed using the Monte Carlo simulation code, MCNPX, at different proton energies. The calculated WER values were compared with National Institute of Standards and Technology(NIST) data, available experimental and analytical results,as well as the FLUKA, SRIM, and SEICS codes. PP and PMMA were associated with the minimum and maximum WER values, respectively. Good agreement was observed between the MCNPX and NIST data. The biggest difference was 0.71% for PS at 150 MeV proton energy. In addition, a relatively large positive correlation between the WER values and the electron density of the dosimetric materials was observed. Finally, it was noted that PE presented the most analogous Depth Dose Characteristics to liquid water. 展开更多
关键词 WATER EQUIVALENT RATIO PROTON therapy Dosimetric MATERIALS MCNPX code
下载PDF
Study on gamma-ray attenuation characteristics of some amino acids for 133Ba,137Cs, and 60Co sources 被引量:1
4
作者 Reza Bagheri Ali Yousefi Seyed Pezhman Shirmardi 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第2期67-81,共15页
Amino acids are the building blocks of proteins,which are the most abundant macromolecules in living cells.From the standpoint of the photon interaction cross sections of amino acids,the mass attenuation coefficients,... Amino acids are the building blocks of proteins,which are the most abundant macromolecules in living cells.From the standpoint of the photon interaction cross sections of amino acids,the mass attenuation coefficients,half and tenth value layers,mean free path,effective atomic and electronic cross sections,effective atomic number,and effective electron density of fifteen essential amino acids have been determined for 133Ba,137Cs,and 60Co gamma-ray sources.The MCNP-4C code and the XCOM program have been used to calculate these parameters.The results have been compared to the available experimental and theoretical data.The theoretical results agreed with the experimental data,with RD values of ≤±7%.In the energy region of 81-1332.5 keV,it was found that the μm,σa,and revalues of the amino acids decreased as the photon energy increased,and the increasing density of amino acids had no steady effect on these quantities.Additionally,results demonstrated that the HVL,TVL,and MFP values increased with the increase in photon energy.The μm,σa,and Zeff values of aspartic acid were the highest among those of all amino acids,and they were the lowest for isoleucine.The Zeff value of each sample containing H,C,N,and O atoms was nearly constant in the studied energy region.The Neffvalues of the studied amino acids varied in the range of 3.14×10^23-3.44×10^23 electron/g.Furthermore,the Neffvalues were approximately independent of the amino acid type in this energy region. 展开更多
关键词 Amino acids Mass attenuation coefficient Effective electron density and atomic number MCNP-4C XCOM
下载PDF
Geant4 Comparative Study of Affecting Different Parameters on Optical Photons Related to the Plastic Scintillation Detector 被引量:1
5
作者 M. Ebrahimi Shohani S. M. Golgoun +6 位作者 M. Aminipour A. Shabani A. R. Mazoochi R. Maghsoudi A. Olfateh S. M. Taheri M. R. Davarpanah 《Journal of Physical Science and Application》 2017年第6期43-50,共8页
在这研究,塑料闪烁器察觉者的不同参数被 Geant4 模拟工具箱调查。这些参数由 PMT 以及表面的半径,长度和位置组成了反射打并且完成选择。而且,二器官的塑料材料的反应时间分布被学习。结果显示收集光光子与 PMT 半径头一起有一种线... 在这研究,塑料闪烁器察觉者的不同参数被 Geant4 模拟工具箱调查。这些参数由 PMT 以及表面的半径,长度和位置组成了反射打并且完成选择。而且,二器官的塑料材料的反应时间分布被学习。结果显示收集光光子与 PMT 半径头一起有一种线性关系。另外, PMT 的垂直地点与光光子收集有一种非线性的关系。然而,收集由增加 PMT 长度或动人的 PMT 头减少了水平位置。二塑料闪烁器材料的反应功能在对试验性的出版结果的好同意。另外, Geant4 放射运输代码能模仿事件放射光子并且预言随后的事件到 PMT 头很好。结果显示 BC-404 有更快的焕发性质对 BC-400 器官的闪烁器材料。在 Geant4 产量之间的比较说明最好的反射镜材料和表面为光光子完成类型,这是地面 TiO <sub>2</sub> 。 展开更多
关键词 GEANT4 塑料材料 光子 学习 水平位置 PMT 闪烁器 时间分布
下载PDF
Two-phase flow component fraction measurement using gamma-ray attenuation technique
6
作者 Mohsen Sharifzadeh Hosein Khalafi +1 位作者 Hosein Afarideh Ehsanallah Noori 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第6期196-202,共7页
Multiphase flow meters as the potential alternatives to separation and metering techniques have been in rapid development since 1980 s.Before its field operation,the instrument should be calibrated in a standard test-... Multiphase flow meters as the potential alternatives to separation and metering techniques have been in rapid development since 1980 s.Before its field operation,the instrument should be calibrated in a standard test-facility.In spite of the known medium and large scale facilities all over the world,we developed a laboratory scale instrument for component fraction measurements.It has a two-phase flow homogenizer loop with the clamp-on potential of the meters to provide a regime independent measurement.It is capable of delivering a complete homogenization by γ-ray densitometer.With an error of±5%in component fraction measurements,this instrument is appropriate for testing and calibrating other meters. 展开更多
关键词 COMPONENT FRACTION MEASUREMENT Homogenization MATLAB-Based algorithm Pencilbeam COLLIMATION GAMMA-RAY ATTENUATION
下载PDF
Effects of Contents of Multiwall Carbon Nanotubes in Polyaniline Films on Optical and Electrical Properties of Polyaniline
7
作者 N.Bafandeh M.M.Larijani +2 位作者 A.Shafiekhani M.R.Hantehzadeh N.Sheikh 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第11期116-119,共4页
We investigate the effects of different contents of multiwall carbon nanotubes (MWCNTs) on optical and electrical properties of polyaniline (PANI). The MWCNTs/PANI composites are deposited on glass substrates coat... We investigate the effects of different contents of multiwall carbon nanotubes (MWCNTs) on optical and electrical properties of polyaniline (PANI). The MWCNTs/PANI composites are deposited on glass substrates coated with indium tin oxide (ITO) by the spin-coating technique. The scanning electron microscopy shows that nanotubes are coated with the PANI layer and x-ray diffraction patterns show that all deposited composite films have an amorphous character. The analysis of a UV-vis spectrophotometer indicates the blue shift of the absorbance peak and a decrease in optical band gap value by the enhancement of the CNT content in the PANI matrix while the Urbach energy increases. The Raman spectrum shows the blue shift 1404→1417cm^-1 and photoluminescence spectra show an increase in the intensity of characteristic PANI peak at 436 nm with the increasing CNT content. 展开更多
关键词 PANI of CNT in CNTS on
下载PDF
How crystal configuration affects the position detection accuracy in pixelated molecular SPECT imaging systems?
8
作者 Hojjat Mahani Gholamreza Raisali +1 位作者 Alireza Kamali-Asl Mohammad Reza Ay 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第4期24-30,共7页
It is well known that inter-crystal scattering and penetration(ICS-P) are major spatial resolution limiting parameters in dedicated SPECT scanners with pixelated crystal.In this study,the effect of ICS-P on crystal id... It is well known that inter-crystal scattering and penetration(ICS-P) are major spatial resolution limiting parameters in dedicated SPECT scanners with pixelated crystal.In this study,the effect of ICS-P on crystal identification in different crystal configurations was evaluated using GATE Monte Carlo simulation.A ^(99m)Tc pencil-beam toward central crystal element was utilized.Beam incident angle was assumed to vary from 0° to 45° in 5° steps.The effects of various crystal configurations such as pixel-size,pixel-gap,and crystal material were studied.The influence of photon energy on the crystal identification(CI) was also investigated.Position detection accuracy(PDA) was defined as a factor indicating performance of the crystal.Furthermore,a set of ^(99m)Tc point-source simulations was performed in order to calculate peak-to-valley(PVR) ratio for each configuration.The results show that the CsI(Na)manifests higher PDA than NaI(TI) and YAP(Ce).In addition,as the incident angle increases,the crystal becomes less accurate in positioning of the events.Beyond a crystal-dependent critical angle,the PDA monotonically reduces.The PDA reaches 0.44 for the CsI(Na) at 45° beam angle.The PDAs obtained by the point-source evaluation also behave the same as for the pencil-beam irradiations.In addition,the PVRs derived from flood images linearly correlate their corresponding PDAs.In conclusion,quantitative assessment of ICS-P is mandatory for scanner design and modeling the system matrix during iterative reconstruction algorithms for the purpose of resolution modeling in ultra-high-resolution SPECT. 展开更多
关键词 MONTE Carlo GATE MOLECULAR SPECT POSITION detection accuracy Pixelated CRYSTAL
下载PDF
A New Numerical Approach to Evaluate Variation of Electric Field Strength at the End of Particle Trajectory in Nuclear Track Detectors
9
作者 孙秀冬 Ali Mostofizadeh +1 位作者 侯春风 M. Reza Kardan 《Chinese Physics Letters》 SCIE CAS CSCD 2008年第1期81-84,共4页
A geometrical model for an electrochemical etching (ECE) track in a dielectric detector is defined and a primaxy programme is written to generate the track. The generated track is transformed to an M× N matrix ... A geometrical model for an electrochemical etching (ECE) track in a dielectric detector is defined and a primaxy programme is written to generate the track. The generated track is transformed to an M× N matrix of primary voltages. Using a numerical method, the matrix of final voltages is computed, and using another numerical approach, the electric field strengths in the elements of detector volume are computed. The final field strength at the end of particle trajectory is obtained. The results of our numerical computation show that there are exact correlations between the field strength at the end of particle trajectory and the parameters of track under ECE. It is found that although two traditional models of Mason and Smythe in dielectrics can be partly applied for short and long tracks, none of them are able to explain the behaviour of field strength in a ‘general case'. Furthermore, we find that there is an expressive relationship between the field strength and the incidence angle of impacted particle, while the mentioned traditional models are not able to explain this effect. 展开更多
关键词 PULSARS x-ray spectra relativity and gravitation REDSHIFT
下载PDF
The Calibration and Use of a New Ring-Shaped Ionization Chamber for Monitoring and Dosimetry of X-Ray Beams
10
作者 Babak Sharifi Hossein Zamani Zeinali +2 位作者 Anita Alipoor Arjang Shahvar Ali Negarestani 《World Journal of Nuclear Science and Technology》 2015年第3期200-207,共8页
Today, dosimeters are used generally for dosimetry of the diagnostic X-ray beam. Ionization chambers are appropriate instruments for monitoring and also the dosimetry of X-ray beam in medical diagnostic equipment. The... Today, dosimeters are used generally for dosimetry of the diagnostic X-ray beam. Ionization chambers are appropriate instruments for monitoring and also the dosimetry of X-ray beam in medical diagnostic equipment. The present work introduces design and investigation of a new ring-shaped monitor chamber with a PMMA body, graphite-coated PMMA windows (0.5 mm thick), a special graphite-foil central electrode (0.1 mm thick, 0.7 g/cm3 dense) that creating two sensitive volumes and a central hole for crossing the radiation beam with less attenuation. The results of performance tests conducted at the Nuclear Science and Technology Research Institute, AEOI in Karaj- Iran proved the high short and long-term stability, the very low leakage current, the low directional dependence and very high ion collection efficiency through the special design of the collecting electrode. Moreover, the FLUKA Monte Carlo simulations certified the negligible effect of central electrode on this new ring-shaped monitor chamber. According to the results of the performance tests, the new monitor chamber can be used as a standard dosimeter in order to monitor X-ray beam in primary standard dosimetry laboratories. 展开更多
关键词 Ring-Shaped Monitor CHAMBER Diagnostic X-RAY Beam Quality Control Tests Low DENS Graphite-Foil Central Electrode
下载PDF
A Flexible Multichannel Digital Random Pulse Generator Based on FPGA
11
作者 Mohammad Arkani Hossein Khalafi Naser Vosoughi 《World Journal of Nuclear Science and Technology》 2013年第4期109-116,共8页
The present paper describes a multichannel digital random pulse generator implemented in a 65-nm FPGA device. The random time interval generation is based on inverse transformation method. The output pulse generation ... The present paper describes a multichannel digital random pulse generator implemented in a 65-nm FPGA device. The random time interval generation is based on inverse transformation method. The output pulse generation rate, pulse width and the probability distribution function (PDF) of each channel might be individually selected by the computer through a USB cable connection. Statistical properties of the output channels can be adjusted and recorded in a fully dynamic flexible manner. The Poisson and uniform PDFs were tested and implemented for up to eight different channels in experiment, however, the implementation of any arbitrary PDF is possible by programming capability of the device as well. Detailed experimental results are expressed in the manuscript. The proposed equipment makes it possible to verify the complicated multichannel detection systems without having the radioactive experimental tests. This is a low cost instrumentation due to the FPGA-based construction. 展开更多
关键词 Field PROGRAMMABLE GATE Array (FPGA) RANDOM Pulse GENERATOR Probability Distribution Function
下载PDF
Radiolabeled FMLF a Valuable Peptide for Diagnostic Imaging
12
作者 Fatemeh Keshavarzi Parviz Ashtari 《Journal of Pharmacy and Pharmacology》 2014年第1期70-78,共9页
关键词 药剂学 药理学 药学 数学 物理学 化学
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部