An accurate mapping and understanding of remaining oil distribution is very important for water control and stabilize oil production of mature oilfields in ultra-high water-cut stage.Currently,the Tuo-21 Fault Block o...An accurate mapping and understanding of remaining oil distribution is very important for water control and stabilize oil production of mature oilfields in ultra-high water-cut stage.Currently,the Tuo-21 Fault Block of the Shengtuo Oilfield has entered the stage of ultra-high water cut(97.2%).Poor adaptability of the well pattern,ineffective water injection cycle and low efficiency of engineering measures(such as workover,re-perforation and utilization of high-capacity pumps)are the significant problems in the ultra-high water-cut reservoir.In order to accurately describe the oil and water flow characteristics,relative permeability curves at high water injection multiple(injected pore volume)and a semiquantitative method is applied to perform fine reservoir simulation of the Sand group 3e7 in the Block.An accurate reservoir model is built and history matching is performed.The distribution characteristics of remaining oil in lateral and vertical directions are quantitatively simulated and analyzed.The results show that the numerical simulation considering relative permeability at high injection multiple can reflect truly the remaining oil distribution characteristics after water flooding in an ultrahigh water-cut stage.The distribution of remaining oil saturation can be mapped more accurately and quantitatively by using the‘four-points and five-types’classification method,providing a basis for potential tapping of various remaining oil types of oil reservoirs in late-stage of development with high water-cut.展开更多
This study aims to further enhance the oil recovery of reservoirs in the Zhong-2 Block of the Gudao Oilfield by identifying the most effective microbial-flooding activator systems and applying them in the field.We beg...This study aims to further enhance the oil recovery of reservoirs in the Zhong-2 Block of the Gudao Oilfield by identifying the most effective microbial-flooding activator systems and applying them in the field.We began by analyzing the structure of the reservoirs'endogenous microbial communities to understand the potential impact of microbial flooding.This was followed by determining commonly used activator systems based on their abilities to stimulate oil-displacement functional bacteria.Through laboratory experiments on oil displacement efficiency and sweep characteristics,we determined the optimal activator injection method(injection ratio)and the requisite bacterial concentration for maximal microbial-flooding efficacy.Finally,we selected the optimal activator systems and applied them to field tests.Our findings suggest the target block is highly receptive to microbial-flooding.In terms of performance,the activator systems ranked as No.3>No.4>No.1>No.2.Interestingly,a deep activator system,when compared to the top-performing No.3 system,exhibited a higher bacterial concentration peak and longer peaking duration.Optimal oil displacement effects were observed at a 1:4 vol ratio between the No.3 activator and deep activator systems,with bacterial concentrations of up to 106 cells/mL or above.Field tests with the selected activator systems,following a specific injection protocol,demonstrated a notable increase in oil production and a reduction in water cut.展开更多
基金funded by SINOPEC Science and Technology Project P18080by National Energy Administration Research and Development Center Project.
文摘An accurate mapping and understanding of remaining oil distribution is very important for water control and stabilize oil production of mature oilfields in ultra-high water-cut stage.Currently,the Tuo-21 Fault Block of the Shengtuo Oilfield has entered the stage of ultra-high water cut(97.2%).Poor adaptability of the well pattern,ineffective water injection cycle and low efficiency of engineering measures(such as workover,re-perforation and utilization of high-capacity pumps)are the significant problems in the ultra-high water-cut reservoir.In order to accurately describe the oil and water flow characteristics,relative permeability curves at high water injection multiple(injected pore volume)and a semiquantitative method is applied to perform fine reservoir simulation of the Sand group 3e7 in the Block.An accurate reservoir model is built and history matching is performed.The distribution characteristics of remaining oil in lateral and vertical directions are quantitatively simulated and analyzed.The results show that the numerical simulation considering relative permeability at high injection multiple can reflect truly the remaining oil distribution characteristics after water flooding in an ultrahigh water-cut stage.The distribution of remaining oil saturation can be mapped more accurately and quantitatively by using the‘four-points and five-types’classification method,providing a basis for potential tapping of various remaining oil types of oil reservoirs in late-stage of development with high water-cut.
基金funded by the National Natural Science Foun-dation of China(No.51974343)the China Postdoctoral Science Foundation(No.2021M703588)the Open Fund of Hubei Key Laboratory of Drilling and Production Engineering for Oil and Gas(Yangtze University)(No.YQZC202307).
文摘This study aims to further enhance the oil recovery of reservoirs in the Zhong-2 Block of the Gudao Oilfield by identifying the most effective microbial-flooding activator systems and applying them in the field.We began by analyzing the structure of the reservoirs'endogenous microbial communities to understand the potential impact of microbial flooding.This was followed by determining commonly used activator systems based on their abilities to stimulate oil-displacement functional bacteria.Through laboratory experiments on oil displacement efficiency and sweep characteristics,we determined the optimal activator injection method(injection ratio)and the requisite bacterial concentration for maximal microbial-flooding efficacy.Finally,we selected the optimal activator systems and applied them to field tests.Our findings suggest the target block is highly receptive to microbial-flooding.In terms of performance,the activator systems ranked as No.3>No.4>No.1>No.2.Interestingly,a deep activator system,when compared to the top-performing No.3 system,exhibited a higher bacterial concentration peak and longer peaking duration.Optimal oil displacement effects were observed at a 1:4 vol ratio between the No.3 activator and deep activator systems,with bacterial concentrations of up to 106 cells/mL or above.Field tests with the selected activator systems,following a specific injection protocol,demonstrated a notable increase in oil production and a reduction in water cut.