With considering the influence of equivalent plastic strain on void-damage and taking Lemaitre damage equivalent stress as plastic potential, based on continuous damage mechanics theory, a new criterion for ductile fr...With considering the influence of equivalent plastic strain on void-damage and taking Lemaitre damage equivalent stress as plastic potential, based on continuous damage mechanics theory, a new criterion for ductile fracture is derived. The two key material constants in the criterion are determined by the combination of tension tests with FE (finite element) simulation. On the basis of the values of stress and strain calculated from commercial finite element software, the forming limit in cylindrical deep drawing of annealed aluminum alloy LY12(M) is predicted by means of the new ductile fracture criterion. Experiments verify that the predicted results are in agreement with the experimental ones. Hence, it is reliable to predict the forming limit in deep drawing by means of the new ductile fracture criterion.展开更多
This paper established practical 3-D gear models to study the stiffness influe ncing factors of a loaded gear by finite element method, such as friction parameters, material properties, an d gear structures. The resea...This paper established practical 3-D gear models to study the stiffness influe ncing factors of a loaded gear by finite element method, such as friction parameters, material properties, an d gear structures. The research shows that, in elastic deformation, gear stiffness increases when sliding frict ion ability of contact pair decreases; meanwhile, the gear structure, especially asymmetric design in gear’ s shaft direction will also decrease gear stiffness.展开更多
Thin film of biodegradable calcium phosphate coated on threaded commercially pure titanium ( cp- Ti ) dental implants has been investigated as one of alternatives to eliminate the problem of the long- term instabil...Thin film of biodegradable calcium phosphate coated on threaded commercially pure titanium ( cp- Ti ) dental implants has been investigated as one of alternatives to eliminate the problem of the long- term instability of plasma sprayed HA coated implants. In order to compare in-vivo bone-to-implant response behavior among as-machined, HA coated and CMP coated groups, each group was implanted into New Zealand white mature male rabbits for 2 and 6 weeks, and then in-vivo biological behavior was examined in terms of H&E staining. Initial stability and removable torques of implants were compared among three groups. Measured removable torque of CMP coated specimen at 6 weeks after inplantation was significantly higher than that of non-coated group, but slightly lower than that of HA coated group, without any inflammatory response at the surrounding of the implants. The initial stability ( ISQ value ; implant stability quotient ) of CMP coated specimen at 2 weeks after implantation was slightly lower than that of HA coated group and significantly higher than that of non-coated group. However, after 6 weeks, ISQ value of CMP coated group was slightly higher than that of HA coated group and significantly higher than that of non-coated group.展开更多
文摘With considering the influence of equivalent plastic strain on void-damage and taking Lemaitre damage equivalent stress as plastic potential, based on continuous damage mechanics theory, a new criterion for ductile fracture is derived. The two key material constants in the criterion are determined by the combination of tension tests with FE (finite element) simulation. On the basis of the values of stress and strain calculated from commercial finite element software, the forming limit in cylindrical deep drawing of annealed aluminum alloy LY12(M) is predicted by means of the new ductile fracture criterion. Experiments verify that the predicted results are in agreement with the experimental ones. Hence, it is reliable to predict the forming limit in deep drawing by means of the new ductile fracture criterion.
文摘This paper established practical 3-D gear models to study the stiffness influe ncing factors of a loaded gear by finite element method, such as friction parameters, material properties, an d gear structures. The research shows that, in elastic deformation, gear stiffness increases when sliding frict ion ability of contact pair decreases; meanwhile, the gear structure, especially asymmetric design in gear’ s shaft direction will also decrease gear stiffness.
文摘Thin film of biodegradable calcium phosphate coated on threaded commercially pure titanium ( cp- Ti ) dental implants has been investigated as one of alternatives to eliminate the problem of the long- term instability of plasma sprayed HA coated implants. In order to compare in-vivo bone-to-implant response behavior among as-machined, HA coated and CMP coated groups, each group was implanted into New Zealand white mature male rabbits for 2 and 6 weeks, and then in-vivo biological behavior was examined in terms of H&E staining. Initial stability and removable torques of implants were compared among three groups. Measured removable torque of CMP coated specimen at 6 weeks after inplantation was significantly higher than that of non-coated group, but slightly lower than that of HA coated group, without any inflammatory response at the surrounding of the implants. The initial stability ( ISQ value ; implant stability quotient ) of CMP coated specimen at 2 weeks after implantation was slightly lower than that of HA coated group and significantly higher than that of non-coated group. However, after 6 weeks, ISQ value of CMP coated group was slightly higher than that of HA coated group and significantly higher than that of non-coated group.