According to ASTM Designation DXXXX Standard Test Method for Determination of Cooling Characteristics of Quenchants by Cooling Curve Analysis with Agitation (Drayton Unit), a test unit was designed using which the coo...According to ASTM Designation DXXXX Standard Test Method for Determination of Cooling Characteristics of Quenchants by Cooling Curve Analysis with Agitation (Drayton Unit), a test unit was designed using which the cooling characteristics of a quenchant at different flow rates and different temperatures can be determined. We discussed the effects of flow rate and temperature on cooling characteristics of fast speed quenching oil. The results show that this unit can be well used for determining cooling characteristics of quechants at different flow rates and different temperatures. At the same time our investigation can provide a reference to the establishment of a standard for determination of cooling characteristics of quenchants with agitation.展开更多
With the finite element analysis of viscous quenchant flow fields of the ASTM assembly, the effective average velocities of flow tubes are introduced in this paper. And through the results of experiments, the influenc...With the finite element analysis of viscous quenchant flow fields of the ASTM assembly, the effective average velocities of flow tubes are introduced in this paper. And through the results of experiments, the influences of quenchant velocities upon the whole cooling processes are discussed.展开更多
基金This paper funded by"The Key Science and TechnologyResearch Project of The Ministry of Education,No.03067"Corresponding
文摘According to ASTM Designation DXXXX Standard Test Method for Determination of Cooling Characteristics of Quenchants by Cooling Curve Analysis with Agitation (Drayton Unit), a test unit was designed using which the cooling characteristics of a quenchant at different flow rates and different temperatures can be determined. We discussed the effects of flow rate and temperature on cooling characteristics of fast speed quenching oil. The results show that this unit can be well used for determining cooling characteristics of quechants at different flow rates and different temperatures. At the same time our investigation can provide a reference to the establishment of a standard for determination of cooling characteristics of quenchants with agitation.
基金This paper funded bu "The key science and Technology Research Project of The Ministry of Education .No.03067"
文摘With the finite element analysis of viscous quenchant flow fields of the ASTM assembly, the effective average velocities of flow tubes are introduced in this paper. And through the results of experiments, the influences of quenchant velocities upon the whole cooling processes are discussed.